My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3246 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3246 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:01:40 PM
Creation date
2/27/2025 1:08:57 PM
Metadata
Fields
Template:
Building Plans
Street #
3246
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19517
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 � X 25 <br />S.H. <br />13 <br />20 X 38 j <br />18 J X 37 i <br />S.H. <br />14 <br />20 X 50 j <br />18 } X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 621 <br />S.H. <br />16 <br />20X72 <br />184X71 j <br />S.H. <br />432 <br />27 1/4 X 26 <br />26 X 25 4 <br />S.H. <br />} 33 <br />27 1/4 X 38 <br />N/A <br />S.H. <br />j 34 <br />27 J X 50 i <br />N/A <br />S.H. <br />J 33 <br />N/A <br />26 x 37 1 <br />S.H. <br />j 34 <br />N/A <br />26 x 50 <br />S.H. <br />J 35 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />} 36 <br />27 4 X 72 <br />26 X 71 112 <br />S.H. <br />22 <br />37 J X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 } X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 i <br />36 } X 50 <br />S.H. <br />25 <br />37 j X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 j X 72 <br />36 J X 71 1 /2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 <br />S.H. <br />33 <br />54 X 38 j <br />52 X 37 <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 4 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />29'-8" L 15'-10" <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less then 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is Iocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />0 <br />+25.6 / -27.8 <br />© <br />+25.6 / -34.3 <br />© <br />+24.5 / -26.7 <br />OD <br />+24.5 / -31.9 <br />O <br />+23.0 / -25.2 <br />) <br />+23.0 / -28.9 <br />W <br />SEE SN SHEET SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE <br />IS AN "ULTIMATE" WIND SPEED. THE <br />WIND PRESSURES LISTED ABOVE ARE <br />ALLOWABLE PRESSURES <br />WALL LEGEND <br />[I1111111111111111 - -•- <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 24 <br />TOTAL AREA 2376 <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />EXT CONC WALL <br />EXT FRAME 2 x 4 <br />EXT FRAME 2 x 6 <br />CONDITIONED CEILING <br />R-4.1 HIGH PERM <br />R-11/R-13 KRAFT FACED <br />R-19 KRAFT FACED <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0 <br />Z co <br />Z N <br />Z aq <br />Q <br />` <br />w <br />r <br />�_ p <br />w <br />O <br />D-'(A <br />~ <br />C <br />t/ i ZD <br />0 <br />o 0 <br />U <br />w <br />— 8 <br />W ~ E <br />a� M <br />c°' m M <br />0` 00 <br />= <br />U <br />Y LL 00 <br />C'L <br />Y <br /><t0 <br />LO O <br />Sao <br />A' <br />B <br />NI BDC <br />e <br />01: a ... : - <br />.L^J...E.ci <br />c •� <br />Z <br />": Hr z <br />0 r� 4D� o <br />r <br />!1/ <br />�V <br />10 <br />.'� <br />LL W $ S. <br />U <br />U <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z (V <br />O N n <br />> U-) O <br />M <br />N L <br />fu <br />U <br />IZ 00 <br />Q <br />z�� <br />W J� <br />d- <br />W <br />za <br />�aa <br />ga�� <br />z� <br />z <br />NYE <br />2z <br />S <br />r-1 <br />iR <br />M <br />O <br />� <br />�a <br />U <br />= <br />J <br />g o., <br />C'4 <br />BSA <br />Z <br />~ <br />Ln <br />a <br />j <br />J <br />LL1 <br />z <br />a o <br />fag <br />Ln <br />ZLU <br />m <br />o <br />^ <br />0- <br />G <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION N0. 10 <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.