My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36503 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36503 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:18:51 AM
Creation date
2/27/2025 1:09:07 PM
Metadata
Fields
Template:
Building Plans
Street #
36503
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLD UP WEATHER <br />RESISTIVE BARRIER NEATHER RESISTIVE WINDOW UNIT <br />TEMPORARILY SECURE 13ARRIER FLASHING REQUIREMENTS <br />WEATHER DOOR ROUGH OPENING SLOPE <br />0) <br />RESISITIVE (3) <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall Q <br />BARRIER WOOD FRAME CONSTR, > C- <br />TAPE EXTERIOR 14%1" BE -AD OF CONS'TR (0.6 cm : 30.5 cm) include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDLR SFLF-ADHERED FLASHING 0 <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND %- <br />WALL BY 6 IN. RETURN UP JAMS 6�' USE LIU1,J111D R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water Co Q_ <br />NAIL BRAND OREOUAL WLAi HER EXI ERIOR within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of 40 '@ (1) <br />PROOF CAULKING CFMT. FIN, C 4-0 Cn -6-0 <br />WEATHER SELF-ADHFRED FLASHING BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. =3 CU -cu -05 <br />7C3 <br />RESISITIVE <br />0 0 <br />BARRIFR SEAL TOPS OF JOISTS > WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt fett, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other &_ - <br />0 <br />UNDER DECKING <br />0 <br />SUBFLOOR approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />SELF -ADHERED FLASHING (SEE DETAIL WP07 with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other .0 LL_ <br />CU C) -i.- %+- CU <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt Cf) -0 CU > <br />HEAD FLASHING TIE-IN INSTRUXTIONS: RIM JOIST felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building 0 <br />1 , Cut, fold up & temporarily secure weather Cn (1) " I - <br />THESE DETAILS ARE GENERIC AND resistive barrier above header to allow for appendages in a manner to meet the requirements of the exterior wall envelope as described in Sechon R703.1. Cl) %40 03 <br />flashing installation co -I,-, <br />MEANT TO SHOW GENERAL FLASHING 2, Self -adhered flashing plus head flashing under R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based II__ Cn <br />weather resistive barrier <br />AND WATERPROOFING METHODS TO <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />3, Fold weather resistive barrier back over head <br />BE USED. 2) 02 individual layers shall be installed independently such that each layer provides a separate conbnuous plane and any flashing (installed in <br />flashing and seal with tape <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING Scale: NTS SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />FLANGED WINDOW CEMT_ FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER WPM EXTERIOR DOOR WITH DECK - SECTION A WP02 WP03 equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT substant ally nonwater-absor Ing ayer or designed drainage space. <br />EXTERIOR SHEATHING 3/4"-1" BEAD OF CONSTR, INSTALL SEU Al)fit: RH) NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & 11 F AD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />318'CEMENT THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING-Nl- shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />PLASTER UP JAMB 6' USE LIQUID NAIL BRAND FLAN[GED VVINDOVY <br />12 MIL DPYLOK CMU - MASONRY BLOCK ............. OR EQUAL WEATHER PROOF CAULKING (SEE DETAiL WPO I used as flashing shall be applied in accordance with the manufacturer's instructions. AlI flashing shall be applied in a manner to prevent the <br />. ........... <br />EXTREME REFER TO TECHNICAL SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />LETTER ON CHEMICAL RELEASE PAPER <br />WINDOW COMPATIBILITY Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestrabon products shall be sealed at the juncture with <br />FASTENER SELF -ADHERED FLASHING (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 80D or A TM 920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER T <br />1) SEALANT AT SELF -ADHERED FLASHING <br />4) SEALANT JOINT WINDOW BUCK TO EXTEND A MINIMUM 6 ADIAESWE AS SI-+CWN) contraction, ASTMC 1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />OUTSIDE EDGE OF MASONRY <br />WINDOW BUCK BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashing$ <br />THRESHOLD <br />5) SEALANT FR(� 2) SEALANT JOINT shall be installed at the following locations: <br />INSIDE EDGE OF <br />WINDOW FRAME <br />10 WINDOW BUCK <br />ACROSS WINDOW BUCK 41 SECTION -A (SEE DETAIL WP02)...N <br />AND EXTEND TO WINDOW FRAME 1. 1I.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />MASONRY ATTACHED SELF -ADHERED FLASHING finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />6) TOOLED SEALANT PER CODE shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />BEAD BRIDGING REQUIREMENTS 2 following: <br />CLADDING AND MNDOW,,--" 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />FRAME SELF -ADHERED FLASHING 5 <br />3) SEALANT WINDOW FRAME T NAILING FLANGE <br />WINDOW BUCK ALL THE WAY 4 manufacturers instructions, in accordance with the flashing manufacturers instructions. Where flashing instructions or details are <br />AROUND, INCLUDING SILL not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />2 SEAL TOPS OF JOISTS <br />DO NOT FLASH OVER UNDER DECKING sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />BOTTOM NAILING 8 (SEE DETAIL WP07) (2) 7 drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />FLANGE 1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND SELF -ADHERED FLASHING SELF -ADHERED FLASHING SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />FENESTRATION INSTALLATION AND INTERFACE HALF ROUND WINDOW WP04 EXTERIOR DOOR WITH DECK WP05 INSIDE CORNER WP06 1.4 In accordance with FMAIAAMA 100, FMAI AA1AA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAfWDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4. Continuously above all projecting wood trim. <br />SHEATHING 5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6� 6.At wall and roof intersections. <br />Water Resistant Barrier 7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL _7 Lath <br />APPROVED SHEATHING SELF -ADHERED FLASHING Sheathing THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />APPROVED HOUSEWRAP PATCH <br />STRUCTALATH TWIN TRACK 2.5 Stucco <br />3/4" CEMENT PLASTER FLASHING AND WATERPROOFING METHODS TO BE USED. MAR 0 4 1021 <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE 2 <br />_'_�DOUBLE <br />r <br />JOIST <br />-V" SEALANT SOCKET WITH 7/8"Cement Plaster <br />TOOLED APPROVED SEALANT SINGLE Z <br />WOOD BEAM in accordance with 7/8" Cement Plaster <br />Foundation Wail 4 - .-, . \/M <br />JOIST FBELOW SELF -ADHERED FLASHING ASTMC926 in accordance with <br />SELF -ADHERED FLASHING 4 Virtual Review Assist, Inc. <br />ASTMC926 <br />Felt backed metal Pla s Review completed ani approved <br />(2) <br />lathe in accordance Felt backed metal for co pliance with the 2020 F IC 7th Edition <br />31, MIN - lathe in accordance by Debra Anne Klahr P) 2300 <br />withASTMC1063 <br />SELF -ADHERED SELF -ADHERED 4 <br />FLASHING FLASHING <br />with ASTMC1063 <br />5 Building Paper <br />Building Paper <br />7/16'O.S.B. <br />7/16" O.S.B. <br />sheathing <br />SCS 06 02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING SELF -ADHERED FLASHING Metal sheathing <br />DECK JOIST OUTSIDE CORNER FOUNDATION WEEP SCREED <br />EXTRUDED SHOULDER WP07 WP08 WP09 <br />Flashing <br />Weep Screed <br />CIO <br />Installed As Per <br />2x FRAMEWALL ... Manufact. Specs. <br />SELF -ADHERED FLASHING <br />STRIP OF SAF LEGEND Maintain Stampede or similar <br />PRODUCTSDETAILS TILE FINISH--------_ SELF ADHERED FLASHING (SAF) Bottom of cauk bottom <br />DRAINAGE PLANE WRI3 DRAINAGE PLANE jDP) WEATtIER RESISTANT Weep Screed joint only <br />BARRIER (WRB) 1 1/2" to 2" <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO BOND BREAK'4*RB BOND BREAK WEATHER RESISTANT BARRIER Weep Screed <br />F)LATH <br />1/2" DUROCK > SELF FURRING (& Above Roof U) <br />PLASTER ACCESSORY Sheathing Installed As Per <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) CD _SF LATH SHEATHING,'OSB*, PLYWOOD. DENSGLASS Manufact. Specs. <br />2� I (M CU <br />1 *-4" PER PLAN Le <br />Detail Instructions If M. - WRAP DP WRB ONTO <br />1 '-0" PER 9 <br />Refer to the number marked as (�) in each detail that corresponds to the PLAN i HE VERTICAL Cement Plaster 1/2" Cementitious 0 <br />SURFACE TO TOP OF Decorative Finish L. <br />% F: k ANGE A CL <br />with ASTMC926 <br />numbered Items in the list of instructions below: BARRIER S AN AIR in accordance AJI inside and CL <br />SLOPE over wood 2nd <br />3-1 Q" INCH FLANGE <br />1 Install self -adhered flashing in order as shown by numbers 8" CMU > floor outside comer will <br />need to be miter <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps 4" OR 8" CMU cut and caulked all <br />(PER SEAT DEPTH) butt joints need to <br />3. Self -adhered flashing can be substituted for building paper Z STRUCTURAL FRAMING <br />Z C) <br />4. Split the release paper using the ripcord (Split release on demand, 5 5 &J'U%.0,Iked using <br />FILL NTH GROUT 0- 0- F�TRUCTURAL SHEATHING Stampede or sim. <br />embedded in the adhesive layer) - for ease of installation and to W I :-- THIS GAP IS A RESULT OF <br />W PLASTER STOP caulk for all 0 <br />minimize scoring cuts A uJ NATURAL SHRINKAGE STRIP OF SAF <br />DO NOT SEAL. <br />5. Remove all release paper per standard installation instructions and to <br />Cn CONTiNUOUS BACKER - DRAINAGE PLANE WRB CL <br />0 W <br />adhere to substrate using a square piece of flashing material (6" x 6" ROD SEALANT DRIP $CREED PLASTIC _BOND BREAK WRB <br />w W ACCESSORY <br />Minimum) SLOPED MUD BED --- r Cf) <br />6. Fold as shown by arrows cc _SF LATH <br />w ELI CU <br />7. Angle of comer may vary, adjust folding of the flashing accordingly to <br />fit tight to corner VINYL SHOWER PAN 0 <br />Note: <br />8. Mechanically fasten as necessary F-1 <br />SLOPE The building paper and metal lath must be LU <br />Cement installed over the top of the weep screed. <br />PLASTER STOP Plaster <br />A <br />-CONTINUOLK RA(-,KFR Pr)D over block <br />& <br />SEALANT 1 st floor Z <br />CEMENTITIOUS FINISH < <br />_J <br />71 <br />SHOWER SEAT WEEP SCREED DETAIL SHEET No. <br />WP1 1 SOFFIT./CANTILEVER WP10 SCALE: NOT TO SCALE WP1 so <br />
The URL can be used to link to this page
Your browser does not support the video tag.