Laserfiche WebLink
W I <br />W �_ <br />�_ z <br />fy_ LU <br />0 > <br />z <br />W <br />U) <br />z x <br />< 0 <br />1: co <br />A/C <br />DISCONNEC <br />WP <br />GFI <br />PANTRY IGF14P I <br />9 <br />GFI AT <br />30" A. F. F. <br />AV— <br />r -------- <br />DW -------- <br />7�, �TO <br />12k <br />DW <br />TO— <br />r I S <br />� I I 7P <br />SP <br />__0 <br />E3 <br />L2 <br />GFI AT <br />30" A. F. F <br />14'3" <br />KITCHEN <br />77 <br />A r F6'-011 <br />u_ <br />LL <br />GF <br />A <br />TILI <br />10, <br />U) -10, <br />DINING <br />TILITY' ROOM <br />ELEC (�Hj n GFI <br />0 <br />METER <br />ELEC <br />PANEL <br />TWO CAR GARAGE <br />48 <br />9 <br />GFI <br />GFI <br />11 OV CLG- <br />MNT. <br />OUTLET <br />— — — -- — — — — — — — — --- — — — — — — <br />9 <br />0 1 <br />L— — — — — — — — — — — — — — — — — — - J <br />FIRST FLOOR ELECTRICAL PLAN <br />1/411 = 1 1-011 <br />GF <br />21-1111 <br />-9 F, 11P_ <br />9 <br />2'-6" <br />GFI ENTRY <br />WP_ — — <br />HDMI <br />6'- 1 " I <br />LIVING <br />ROOM <br />ELEVATION B <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST TFROM BATH DOOR AND AT <br />LEAST 6'FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2"AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bai*e attached to footer steel <br />GROUNDING PER 250.50 ANDI <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />MAR 0 4 2023 <br />VV0 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editiot, <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W1 <br />EDGE OF <br />SWITCH—,,— <br />SWITCH- <br />41/2-1 <br />DOOR JAMB-11 <br />DUPLEX <br />OUTLET <br />TRIM — <br />BASE ---- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: I <br />11-0 k1_-SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV D U PLEX OUTLET AT 12" <br />11 OV DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />4D-- 11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />1 10V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />@E 220V OUTLET AT 30" <br />1 10V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />bg SWITCH AT 36" <br />Cn <br />fig 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />_0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />WALL MNT FIXTURE NOTE: <br />03 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />40 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />60 50W MR 16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />010 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />_0 CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />0S SMOKE DETECTOR <br />cU-1 8= UNDER CABINET 18" <br />cS-1 8= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />-S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 UNDER CABINET 36" <br />—S-36— SINGLE 36" FLUOR STRIP <br />= D-36 — DOUBLE 36" FLUOR STRIP <br />—S-48— SINGLE 48" FLUOR STRIP <br />— D-48 DOUBLE 48" FLUOR STRIP <br />24"CLG MNT WRAPPED FLUOR LIGHT <br />1 48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9; 24:M 24" VANITY LIGHTING <br />FFF 36:FvR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />INTERCOM SPEAKER AT 6-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GM CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />IS&J ELEC PANEL <br />[0 VACUM OUTLET AT 12" <br />FaCEILING RETURN AIR <br />ED A/C REGISTER <br />(D THERMOSTAT <br />M SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />E <br />> 0 0 <br />U <br />CO U CO <br />0 U <br />C 4) E <br />:) 0 2 <br />< <br />U ­0 < <br />LU <br />00 CN C <br />E 2 <br />c:) .0) <br />co <br />CL <br />LLI <br />W Uj <br />0 <br />W 0 <br />LU Ld 2 �_ 0 <br />< x _j wg�eza� z <br />Lu 0 � <2< < <br />X 0 W U_ 0 0 <br />< <br />L) <br />— <br />F- <br />=) - _j <br />(0 _z: (0 <br />< 0 z C"� LL -0 z 2 0 <br />D _j <br />0(" x'2z0x00MzD <br />U0 <br />Z <br />2 <br />0 0 <br />0 <br />0 <br />Z <br />W W CL > W w W V5 M x <br />1 CD 0- 0 Z �e 0 z LL 0 <br />_J�< W�mzujz <br />0 5 <br />0- <br />L) CL <br />Cn <br />LL <br />6 <br /><0W 9 P gwz<< <br />OX 0 D 0 <= <br />< <br />LL < 0 L L <br />0 <br />z <br />LLJ <br />2 I'_ <br />U—) <br />o <br />(0 0 <br />z <br />ce) C:) <br />< cr) ll�_ <br />L0 <br />W <br />14, <br />LL <br />M W <br />- P­ <br />z <br />< W < U� <br />cy) <br />00 <br />< >- < <br />Z 0 <br />3: <br />LUz <br />W <br />_j 0 <br />0 <br />CD <br />Mill <br />I <br />I <br />I <br />00 <br />0 <br />CD <br />ol <br />1,- <br />Co <br />N <br />C) <br />z <br />0 <br />W <br />>1 <br />Ic <br />IC61 <br />I <br />I <br />Cr <br />00 <br />Cl) <br />Z�- <br />0 <br />W <br /><z <br />W <br />zz <br />000 <br />cy) <br />0 <br />0 <br />W — <br />()0(1) <br />Lr) <br />-0 <br />0 <br />=) z 5; <br />ow- <br />0 <br />or< <br />< <br />z <br />W-CL <br />W, � r. <br />W < <br />0co <br />W � <br />g- w <br />2 <br />r+4 <br />�- F- <br />O=)0 <br />ZOM <br />W <br />< <br />00 <br />0 <br />zwo <br />C:) <br />< <br />0 <br />:5 LU X <br />Z LL <br />e. <br />3 <br />z <br />z <br />z <br />0 <br />0 <br />0 <br />CL <br />1 <br />z <br />A6 <br />z <br />z <br />LILI <br />wo <br />> <br />LAST PLOT DATE <br />z <br />R a <br />0 <br />1 ST FLOOR <br />ELECTRICAL PLAN B <br />