My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36531 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36531 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:41:09 PM
Creation date
2/27/2025 1:09:39 PM
Metadata
Fields
Template:
Building Plans
Street #
36531
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAtJOND-MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1'.2" LCNG 13 4"-1" CROWN) <br />' <br />',i SHEATHING <br />I ri:•� I l I I 16GAx1-1 2" LONG (3.4'"-1" <br />STAPLES icv 6" O.C.'vERT BETWEEN ti �'- <br />STUDS (NOTED THUS:-1^OFFCROWN) STAPLES ra 6" <br />S=T I I I t l 1 O.C. ti/ERT INTO STUDS <br />STAPLES BETWEEN STUD -AS SHOWN �% <br />NOTED THUS:-j <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 314" = Vi <br />*DETAIL EXCEEDS THE REQUIREMENT$ FOR FBCR 703.7." 'LATE-!' <br />*ONLY APPLIES TO LENNAR TPA/JAX** <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4"-1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C 1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />Mel <br />STUB -OUT FOR <br />GAS METER O <br />0 <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13"1 <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16"1 <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19"1 <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />"TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE �, <br />15/32" CDX <br />m <br />a <br />PLYWOOD OR <br />c7 <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH 2-3/8 INCH NAIL LENGTH <br />NOTE: " FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + + <br />+ <br />+ + <br />+ + + + + + + + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+++ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />P — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />60 2.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap + <br />t <br />FILL CELLS r STD. 90° HOOK BOND BEAM <br />W <br />.. .... <br />`t Ir <br />STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />#5 CONT. <br />........... <br />FROM <br />CFOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR RE 'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" mir. <br />2" max <br />- � 4 max. <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGYs" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />----- - Under 2nd floor Coh imn w/ 1n 1r <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer <br />=1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squasll blocks and <br />require additional <br />wall or beam below." <br />consideration. Check <br />local building <br />code for appropriate <br />1/16" <br />Zor-20 <br />details in <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (1 Oil) nails at 6" inr. <br />`' Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />fl <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />7-3 <br />6", A 1 2" ROUND HOLE MAY 6„ 6", DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN tYz" <br />Round Hole Diameter (in) <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />8.875 <br />10 <br />1 1 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />2 <br />3 <br />5 <br />6_ <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />V-1"' <br />V-2" <br />V-2" <br />V-3"" <br />V-3" <br />V-7" <br />1'-11" <br />2=1� <br />2--9" <br />3'-2„ <br />3'-7,, <br />12 <br />V-0" <br />V-1" <br />Vi <br />V-2" <br />1"-3" <br />1"1 <br />2'-4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5"-4" <br />16 <br />V-0" <br />V-1" <br />V-2" <br />1'-2" <br />V-7'" <br />2'-5" <br />T-2" <br />3'-10" <br />4'_9" <br />5'-7" <br />6'-4"" <br />T-2" <br />20 <br />1'-0" <br />V-1" <br />V-2" <br />1'-2" <br />2'-0"" <br />3'-0" <br />4'-0" <br />IT-1 0" <br />5'-11" <br />W-11" <br />7'-11" <br />8'-11" <br />24 <br />1'-0" <br />1'- 1 " <br />V-2" <br />V-W <br />2'-5" <br />3'-7" <br />4%9" <br />5'-10" <br />T 2" <br />$' 4" <br />9' 6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install fight to top flange. <br />Joist <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gaP <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"1 gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />' height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series De th End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />- <br />BCI6000sR <br />BCI65il <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC160s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/8"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) " <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />l� <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />E AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM <br />SEE PLAN FOR °• a . • .; . • <br />FOUNDATION INFO a <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />—...I I I- <br />rvu i mrlx 4 rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />•�® LOCATION OF <br />° SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18) 10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />� v <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />1=III—III- <br />I I <br />1 I <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />a <br />PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION i <br />� —\e • � • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />TYP. FND. PENETRATIONS <br />V G <br />SCALE: N.T.S.------� . d <br />I I TI 1 Ij=j jI I I=11 `� ,Q 1 K 11 1=I I I: <br />OCT 2 8 ZOZZ°� - - - <br />SEE FND. PLN. <br />SIZE & REINF. <br />\/RA <br />Virtual Review Assist, Inc. <br />Plans Review completed and appr d <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />{ <br />N <br />f� <br />co <br />0 <br />L , <br />'li I 'OS <br />a <br />�A,,� <br />w <br />.4 <br />O <br />-i <br />W <br />w <br />0 <br />z <br />a <br />0 N u0 N E <br />W 6M o <br />_cM � Ili <br />� � `Ah i <br />'0 <br />u o <br />s• C3 <br />.N Y uJ QN , <br />6. 00 <br />V a v <br />w <br />Of LU <br />w <br />w Q W J o'1Q,4 <br />wzW Z <br />Q�-JCO0 U_VO0JO <br />Q <br />Q H <br />0 <br />C) <br />I_ <br />0 <br /><C3X ZXI�0Z20a <br />a ofWOZOLu00mZZ U <br />d>zYQZLu zLLOO O�ii <br />C� <br />(f) <br />Z <br />JV' <br />W <br />¢~w in—_�W M0�¢ <br />0LL Q o 0 o ��qa <br />LL <br />11 <br />0 <br />Z N <br />O� <br />anti <br />Ifl�CMO <br />� (10 <br />W < Ln <br />of a- M <br />z <br />Q. T11 <br />Q >- Q 00 <br />Z U F- <br />Z <br />W <br />Wo <br />J <br />0 <br />It <br />N <br />O <br />CV <br />I` <br />N <br />0 <br />O <br />00 <br />CD <br />ao <br />CD <br />N <br />C) <br />N <br />C) <br />N <br />•— <br />N <br />.— <br />N <br />C)O <br />N <br />O <br />N <br />O <br />N <br />C) <br />N <br />C) <br />N <br />CD <br />N <br />C) <br />N <br />M <br />N <br />O <br />��- <br />O <br />O <br />A <br />�- <br />� <br />N <br />0 <br />M <br />w <br />C)0 <br />4- <br />0 <br />� <br />C) <br />CD <br />e- <br />� <br />O <br />CD <br />CD <br />1 <br />4 <br />N,^ <br />w J <br />> <br />O <br />O <br />N <br />O <br />cM <br />C] <br />O <br />to <br />O <br />Ct, <br />O <br />1` <br />00 <br />�/� <br />vJ <br />Z Z <br />—ZO <br />0-6_0111 <br />WUr> <br />wWa) <br />O <br />vo�� <br />F—O�a <br />a <br />CC W <br />LO <br />(!7 <br />z <br />ZXliz <br />w ii a <br />t. <br />< <br />Q <br />=mOZ <br />H_W <br />(INz <br />V <br />O � tz J <br />M <br />w <br />}Irk <br />Of <br />M <br />a <br />Z <br />Z Z u- <br />00 <br />N <br />0a <br />w <br />O <br />Z <br />Q <br />Z <br />Z <br />Sao <br />U <br />U <br />a <br />Oo <br />c <br />a <br />Z <br />SN1I <br />Z <br />z <br />W <br />N <br />N <br />O <br />LAST PLOT DATE <br />> <br />Aug. 8, 22 <br />Z <br />O <br />STRUCTURAL <br />— <br />J <br />DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.