Laserfiche WebLink
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV -ABOVE MLDG - MOULDING THE FOLLOWING TECHNICAL CODES SHALL APPLY: VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />AFF - ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING 1.0 PLAN REVISIONS CS COVER SHEET <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN ¢W ' ` `� N <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 PLAN REVISIONS - `�. N <br />ALUM - ALUMINUM # -NUMBER A2 1ST AND 2ND FLOOR PLAN A <br />ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 do A3 STAIR DETAILS ice" '•.� a <br />AT - ALUMINUM THRESHOLD OC - ON CENTER 3.0 TRUSS CONNECTOR REVISION ppr sr�, <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 A4 FRAMING PLANS A <br />4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A5 EXTERIOR ELEVATIONS & ROOF PLAN o AVG -AVERAGE OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME A6.1 1ST FLOOR ELECTRICAL PLAN °O <br />BFE -BASE FLOOD ELEVATION OPP -OPPOSITE 1.6 GALLONS 5.0 ADDING K, L & M ELEVATIONS 'LO <br />BM -BEAM OPT - OPTIONAL A6.2 2ND FLOOR ELECTRICAL PLAN <br />BLK -BLOCK OH - OVER HANG SNO STRUCTURAL NOTES <br />2. WATER -FLOW RATE. <br />BLDG - BUILDING OH CABS- OVERHEAD CABS SN1 STRUCTURAL NOTES4•' Q <br />PUBLIC FACILITIES LAV 0.5 G.P.M. z <br />BRD -BOARD PNT -PAINT FINISH S3 FOUNDATION DETAILS 3'�/r�,�.� �,*�� <br />BRG -BEARING PTD -PAINTED <br />PRIVATE FACILITIES LAV 2.2 G.P.M. S4 FRAME WALL DETAILS <br />BTM -BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. S5 STRUCTURAL DETAILS O <br />BUC - BUILT UP COLUMN PERF -PERFORATED p <br />S6 WALL SECTION DETAILS <br />CAB -CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC SS RETRO FIT DETAILS <br />CLG - CEILING PKT -POCKET ST STAIR DETAILS W <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO S11 PRECAST DETAILS p <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S12 PRECAST DETAILS Q <br />CL - CENTERLINE PSI - POUNDS PER SQUARE PA 1.0 PRODUCT APPROVAL <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.1 PRODUCT APPROVAL <br />CONC - CONCRETE PB - PUSH BUTTON CODE PA 1.2 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA 1.3 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 PA 1.4 PRODUCT APPROVAL 4)O � 0 <br />CTR -CENTER REQD - REQUIRED SH 1.0 HURRICANE SHUTTERS M �, <br />CJ - CONTROL JOINT R/A - RETURN AIR 0 HANDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS 4- +• � O M <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.2 HURRICANE SHUTTERS to V -0-0- 2 M <br />DTL - DETAIL RS - ROUGH SAWN SH 1.3 HURRICANE SHUTTERS <br />0 GUARDRAILS - CHAP. 3 D 0 u <br />DIA - DIAMETER SC - SOLID CORE SH 1.4 HURRICANE SHUTTERS 4-- p U: g o <br />DIM -DIMENSION SCP -SCUPPER STAIRS - CHAP. 3 SH 1.5 HURRICANE SHUTTERS U <br />WP 1.0 WATERPROOFING DETAILS V QN <br />DISCON - DISCONNECT SCRN -SCREEN to w H <br />DW -DISHWASHER SIM -SIMILAR CHIMNEY &FIREPLACE -� 1)a <br />DR -DOOR SHLVS -SHELVES <br />DBL - DOUBLE S/R - SHELF & ROD CHAP. 10 <br />DWG - DRAWING SH - SINGLE HUNG WINDOW <br />EA -EACH SGD - SLIDING GLASS DOOR 0 EGRESS WINDOWS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV - ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SOIN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />EXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS ■ <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR -FLOOR TP - TOILET PAPER HOLDER <br />FLOUR - FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS p ui C w o F- <br />FR DR - FRENCH DOOR VAC -VACUUM W W -j O � � z <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR U W � ° J o u_ 0 o o o_ <br />TO BE TEMPERED GLASS. (SECTION R308) Q H m°� o o x o o m z a <br />GA -GAUGE VERT -VERTICAL Q - D°K zu-u.�zm-j°�-¢< <br />GB -GRAB BAR VIF -VERIFY IN FIELD Z Cywawv�uziwwv��� � � <br />GFI / GFCI - GROUND FAULT CIRCUIT INTERRUP FOR VTR -VENT THROUGH ROOF DIMENSIONING: Cy O Z '' ¢ ° w ¢ z W z w ° a <br />GWB -GYPSUM WALL BOARD WC -WATER CLOSET a Q a 0 ~ o ° � a Xd a a <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD - HEAD WL - WIND LOAD A. 1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC - HANDICAP WDW - WINDOW FURRING\ O <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF TRUCTURAL CORE -STUD z N <br />INT - INTERIOR WD -WOOD AA.. WINDOW OPENINGS: LLI <br />LVL - LAMINATED VENEER LUMBER <br />A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING O <br />LT -LAUNDRY TUB C/) 0 r, <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING > (/) O <br />MAX - MAXIMUM A.5. DOOR OPENINGS: (0 O <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING 0 F M O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING Q U) M j <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED LIL <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR � <br />MC - MEDICINE CABINET FRAME Q W Q In <br />MIN - MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER Ix a, M <br />OF DOOR a- `S 0T0 <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES -AS INDICATED ON PLANS OR FINISH Q i- Q <br />SURFACE TO FINISH SURFACE z U SYMBOLLEGEND: A.6.1.EXAMPLE: 3-0 CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER <br />z <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND W <br />PLUMB. WO <br />= STAIR CALL OUT HEIGHT OF SHEET NUMBER C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: J O <br />\\\tD STEP DOWN 1 -INT ELEV NUMBER C.1. CODE MINIMUM -MAXIMUM DIMENSIONS AND CLEARANCES <br />(� FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS mi <br />�J SEE FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />CARROW SHOWS INTERIOR ELEVATION CA. FRAMED WELLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />ELEV NUMBER UNLESS OTHERWISE NOTED <br />A9 ARROW SHOWS PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />OUT -SEE <br />SCHEDULE ENTEL ELEVAEXTERIOR TION MARKER 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE i I <br />I <br />-----ELEV NUMBER SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LEDGER CALL OUT - LEDGER SCHEDULE SEE 4 A15 2 SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LOCATION OF CUT COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />•, ARROW SHOWS DRAWINGS. <br />3 DIRECTION OF VIEW co <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER O o 0 0 N <br />RECt-- I <br />"VED l 00 MONN <br />OO O - O O I I <br />.Nov .2. 1 20221 1 0 <br />U) <br />N W 0 0 0 0 0 1 <br />Lr)> N M 4 6 I 9 <br />Myri M20-.ia�l�l L0 <br />WCT 2 8 2022 cc)0 <br />QZ <br />O w <br />VV\U 00 <br />0vN <br />NARm 0Lo -0 f- p w _> <br />p <br />p <br />Virtual Review Assist. Inc_ z a�a <br />Not Review completed and approved � r„ � w <br />f& ttophatt wd the 2020 f8C 7th Edjto = w= W <br />Ann* klakT Pxt.� mL <br />1—o <br />4600 W CYPRESS ST SUITE 200 �`' z=u) <br />' NOTICE TO BUILDER & ALL SUBCONTRACTORS n" zoo <br />TAMPA, FL 33607 IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE Q O � W" d <br />z z . 5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING X <br />813.574LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT � Q <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O (� J <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE 0 a_ <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE W <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE Q <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z w <br />C S CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION -r <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THEW 00 INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE 0 <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK 0 LAST PLOT DATE <br />2551 CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE > August 8, Z022 <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. O <br />I COVER SHEET <br />