My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36560 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36560 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:44:49 PM
Creation date
2/27/2025 1:10:21 PM
Metadata
Fields
Template:
Building Plans
Street #
36560
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5362
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />m <br />6'-5" <br />CS <br />BEDROOM <br />#4 <br />Q (V <br />db <br />tl'- I <br />.I <br />A=e <br />F <br />BEDROOM <br />#5 a � A <br />/ L0 <br />/ F / <br />5'-1 <br />6-7" <br />BEDROOM <br />#6 <br />OWNERS <br />BEDROOM <br />9 <br />5-11" <br />h <br />EDRO M <br />4L #3 <br />BATHROOM <br />#2 <br />iAHU /\ <br />CS <br />LIGHT AND <br />SWITCH IN <br />TTIC <br />V �b - <br />- �11 <br />J•f �. <br />W.I.C.1 <br />in <br />�l ' <br />L T-9„ <br />GFA LAUNDRY <br />F <br />LOFT <br />\ 1'_7" <br />ll CSI <br />OWNERS <br />BATHROOM <br />L <br />TO 1ST <br />FLR ELEC <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATIONS A & B' <br />1 /4„ = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />Virtual Review Assist, Inc. <br />Plans Review completed and apprmleq <br />for compliance with the 2020 FBC 7th Lull <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET eo <br />TRIM <br />n <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ_ <br />k <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />�- 4 WAY SWITCH AT 36" <br />_0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—m DIMMER SWITCH AT 36" <br />--0 PUSH-BUTTON DOORBELL <br />{- CLG MNT LT FIXTURE <br />-} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CS SMOKE DETECTOR <br />C SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 --• SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />97, 24 ::;9 24" VANITY LIGHTING <br />36 ;77� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />Q EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />Ej INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />0 CEILING MNT SPEAKER <br />ED CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />lffii;J ELEC PANEL <br />® VACUM OUTLET AT 12" <br />14 CEILING RETURN AIR <br />p A/C REGISTER <br />(1) THERMOSTAT <br />ED SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />V) <br />4) N kf) <br />W 16_ NO q U <br />} <br />4- <br />f� b <br />D(n -a - W <br />V 2 <br />i t <br />�} o°o og <br />Q <br />�N <br />^` <br />w O� <br />V �� c <br />0 E <br />V <br />V ^ a <br />CD W <br />w <br />�wF- 'U w20 <br />'W yza� <br />Wx0^¢000'O <br />���LL <br />CYW0�<Q U)poR00t00 Z <br />Ly wZ <br />v)acwF_O <br />pora <br />O <br />ZQ <br />zL <br />FnZO0O_JM Zwv <br />U- <br />Ow Vi-mwflQ Q <br />OO O OQ Q <br />LL <br />O <br />0 <br />z N <br />O�_ <br />D) 5 ti <br />0 1.-7MO <br />QU)MLf <br />LL <br />2 w <br />z <br />< LLJ < <br />i— W a- <br />W R 00 <br />Z U F- <br />Z <br />W <br />J <br />0 <br />00 <br />i <br />I <br />I <br />1 <br />O <br />0 <br />0 <br />0 <br />o <br />0 <br />M <br />M <br />r <br />O <br />C> <br />C) <br />o�ai <br />Q> <br />o <br />O <br />N <br />o <br />N <br />o <br />z <br />O <br />NIx <br />'^ <br />w <br />> <br />o <br />0 <br />0 <br />0 <br />0 <br />6 <br />1 <br />I <br />Li , <br />'/1 <br />Z~ <br />W <br />�/J <br />QZ <br />O <br />W <br />Zw <br />O <br />WOO <br />U U y <br />LO <br />0 <br />o w - <br />goo <br />�— <br />< <br />TI <br />Z <br />F- <br />a —a <br />d <br />Lii <br />W <br />2 <br />m�� <br />CV <br />W <br />zo= <br />■ ■ <br />(y) <br />W <br /><F-� <br />zwo <br />Q <br />0 <br />Z <br />Z <br />aZ <br />COZ <br />pU <br />CL <br />_o <br />W <br />Z <br />Z <br />w <br />W <br />oo <br />o <br />Q <br />LAST PLOT DATE <br />O <br />" <br />Z <br />�' <br />August 8, 2022 <br />2ND FLOOR <br />—� <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.