Laserfiche WebLink
I <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER <br />SLOPE <br />RESISITIVE <br />0.3 in: 12.0 in <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />I <br />BARRIER <br />VVV <br />��� <br />TAPE <br />EXTERIORR703.2 <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING 3ia"-�° BEAD OF CONSTR. <br />(0.6 cm : 30.5 cm) <br />Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />I <br />3 <br />SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />I <br />I <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />with the upper layer lapped over the lower la ( ) j pp <br />pP y Pp layer not less than 2 inches 51 mm .Where joints occur, felt shall be lapped not less than 6 inches 152 <br />I <br />A88EMB1EDNA"DO" <br />z <br />OR EQUAL WEATHER PROOF CAULKING <br />03 <br />EXTERIOR <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />I <br />�- <br />© <br />CEMT. FIN. <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />WEATHER <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />z <br />TI <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />BARRIER <br />BARRIERR <br />SEAL TOPS OF JOISTS <br />WIRE LATH <br />1. In detached accessory buildings. <br />UNDER DECKING SUBFLOOR <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />I <br />SELF -ADHERED FLASHING <br />(SEE DETAIL WP07) <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />I <br />I <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />I <br />1. Cut, fold up & temporarily secure weather resistive <br />RIM JOIST <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />ESE DETAILS ARE GENERIC AND <br />barrier above header to allow for flashing <br />V1. <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />installation <br />ANT TO SHOW GENERAL FLASHING <br />D WATERPROOFING METHODS TO <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back headIN <br />1 <br />1 <br />11 <br />Exterior Window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />USED. <br />over <br />flashing and seal with tape <br />2 <br />2 <br />O <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />Scale: NTS <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />SELF -ADHERED FLASHING <br />• <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER • <br />1.3 In accordance With FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE <br />BARRIER <br />EXTERIOR DOOR WITH DECK - SECTION A <br />In accordance with the flashingmethod of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with fame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />NEEDED IN CORNERS ADHESIVE <br />4. Continuously above all projecting wood trim. <br />EXTERIOR SHEATHING <br />�,1 <br />INSTALL SELF -ADHERED <br />3 ADHESIVE <br />BEAD OF APPLIED <br />ADHESIVE TO BE APPLIED UNDER <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />P Y <br />FLASHING JAMB & HEAD <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />6. At wall and roof intersections. <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />7. At built-in gutters. <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />, <br />O <br />SCORED <br />R703.6.2.1 Weep Screeds <br />COMPATIBILITY <br />RELEASE PAPER <br />~ <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING, <br />\ s (BEFORE FOLDING, SCORE <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />EXTEND A MINIMUM 6" <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />2 3 <br />THRESHOLD <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />O,- <br />PRODUCTS DETAILS. <br />2 <br />s <br />SELF -ADHERED FLASHING <br />rJ <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />NAILING FLANGE 1 <br />4 <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />0 <br />DO NOT FLASH OVER <br />2 <br />SEAL TOPS OF JOISTS 1 <br />UNDER DECKING <br />6 <br />Detail Instructions <br />Refer to the #Din detail that in <br />BOTTOM NAILING <br />8 <br />(SEE DETAIL WP07) 2 <br />% <br />number marked as each corresponds to the numbered items the list of <br />FLANGE <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />SELF -ADHERED FLASHING <br />1 <br />SELF -ADHERED FLASHING <br />1 <br />SELF -ADHERED FLASHING <br />/ <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER • <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />�Ground� <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />SHEATHING <br />piece of flashing material (6" x 6" Minimum) <br />1 <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />Water Resistant Barrier <br />g. Mechanically fasten as necessary <br />Lath <br />SELF -ADHERED FLASHING <br />Sheathing <br />PATCH <br />Stucco <br />7/8" Cement Plaster <br />DOUBLE <br />® <br />� 4 <br />in accordance With <br />JOIST <br />° a ° <br />ASTMC926 <br />° <br />7/8" Cement Plaster <br />SINGLE <br />JOIST <br />WOOD BEAM <br />BELOW <br />SELF -ADHERED FLASHING <br />° <br />Foundation Wall ° ° <br />Felt backed metal in accordance with <br />lathe in accordance ASTMC926 <br />SELF -ADHERED FLASHING 1 <br />a a <br />° <br />With ASTMC1063 <br />° ° <br />Felt backed metal <br />3" MIN 2 <br />Q °° <br />Building Paper lathe in accordance <br />SELF -ADHERED <br />SELF -ADHERED <br />4 <br />with ASTMC1063 <br />FLASHING <br />FLASHING O <br />2 <br />,��� 7/16" O.S.B. <br />Building Paper <br />5 <br />st <br />sheathing <br />7/16" O.S.B. <br />Metal <br />Flashing '; sheathing <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING 111111118 <br />FOUNDATION WEEP SCREED • <br />DECK JOIST <br />OUTSIDE CORNER • <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of Stampede or similar <br />Weep Screed cauk bottom <br />1 1/2" to 2" joint only <br />Above Roof Weep Screed <br />Sheathing Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Cement Plaster Decorative Finish <br />in accordance <br />With ASTMC926 v,o o•- All inside and <br />over wood 2nd ,o.o•° • o <br />outside corner will <br />•,o• • <br />floor . °, <br />• need to be miter <br />•.°•° <br />cut and caulked all <br />'°°°o.o• o,o•: butt joints need to <br />• o. ,o•• becaulked using <br />• �•° ° <br />• ° ° <br />Stampede or sim. <br />caulk for all <br />Note: <br />The building paper and metal lath must be <br />Cement installed over the top of the weep screed. <br />Plaster <br />over block <br />1 st floor <br />WEEP SCREED DETAIL <br />NOT USED <br />' <br />NOT USED <br />NOT USED <br />SCALE: NOT TO SCALE <br />Z M <br />Z <br />Z <br />Q <br />a <br />�✓ <br />cn <br />4--J Lu <br />C� o <br />°O w <br />Ln <br />U <br />mo <br />M <br />C-i <br />N <br />U <br />Q ' <br />" 00 <br />pQo <br />e D. <br />ry� <br />N N <br />IW <br />CN i <br />LU N M <br />WWW.FDSENG.COM 0 ❑ <br />00 <br />0 <br />N <br />O <br />N <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />za <br />4f Q <br />a~ a <br />�z 0 <br />W <br />�Z <br />C1)FF� <br />Q <br />Q- <br />UJ <br />0 <br />Z <br />- <br />�O <br />0 <br />O <br />N <br />'� <br />O <br />u, <br />cn. <br />N <br />M <br />Cr <br />LU <br />g � <br />J p; <br />¢v�„ <br />ZLn <br />r14 <br />f <br />Z <br />W <br />J <br />N <br />LA <br />* <br />LLJ <br />LJ.I <br />0� <br />d " i3 <br />� u <br />m <br />06 <br />Z <br />Z <br />:5 <br />`',,W <br />LU <br />O <br />•-+ <br />10- <br />(A <br />s <br />SCALE : AS NOTED <br />DATE : 6/20/2018 <br />TECH: M]AMES <br />VERSION NO. 4ol <br />SHEET NO. <br />W P <br />