Laserfiche WebLink
:P.,.: -:.0 aa� ALTERNATE POWERS E E E <br />::• ' STEEL LINTEL <br />O O O o z <br />. 8F8-1B/1T 8F8-0B/17 <br />TYPE DESIGNATION #SREBARATTOP Z <br />O ® �• #5 REBAR AT TOP 0 <br />:0, , ♦ : O, • • • F = FILLED WITH () O Q 1-1/2" CLEAR Q <br />• - MIN.(1)REQ'D MIN. 1 RE D <br />O O O O O O O O ' I• GROUT / U= UNFILLED a -112" <br />8RF14-1B/1T 8RF14-0B/1T 8F16-1B/1T 8F16-06/1T :O,• • • R = RECESSED ILEAR " <br />O O O O Qn'• OF #5 � _ <br />© O © O REBAR @ BOTTOM • L Q E E Z CZ <br />OF LINTEL CAVITY ° <br />8F20-1 B/1 T 8F20 OB/1 T � aC.M.U. � a � N UI <br />G ¢ = a Q C.M.U. MIN . 0 Q) <br />MIN.O O MIN O MIN. .� w <br />a) <br />-:;a; ':A: ;p;:a ':,a: : a.•; ; .•; .; ;; ; 8F16- B/1 T � g • °d , .� _ <br />,, , , . . ,, • ,, , h ° GROUT <br />• , ` ,,` ' • . • • . `: " • , ` : �NOMIN QUANTITY OF • 5 REBAR AT 8 ai 4 Jr^, \ O U E <br />O O #5 REBAR AT ° BOTTOM OF c`i Fd D D (� o <br />8RF6-OB/1T WIDTH #5 REBAR AT • : :' ' .' , 0 4 Q 0 �% Q MIN, (1) REQ'D BOTTOM N f` <br />•, . TOP LINTEL CAVITY <br />•. •. •, •, •. . •. NOMINA <br />• "; ; , �; © —BOTTOM REINFORCING �{ <br />�' . • ,• . •. HEIGHT PROVIDED IN LINTEL `—` Q ` V U m <br />• ' , ," ; : , ; ; ;' ; ; • 7-5/8"ACTUAL (VARIES) _cn <br />. , , •LU <br />MINAL WIDTH <br />♦•� '• 16 GAUGE POWERS tD N <br />.O• ,• STEEL BOXED LINTEL —_ O <br />• , • , • , • , • • W <br />O O ; POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />O •' . •' "• .. Ifc precast lintels = 3500 psi. <br />8F20-18-2T ; , •; , ; , ; ,,• ; 2c prestressed lintels = 6000 psi. ONLY IF NOTED ON LINTEL PLAN LINTEL PLAN NOTES: Q ° `� a o <br />O O O O §routed per ASTM C476 fg = 3000 psi w/ 1. Refer to manufacturer's specifications for installation. — <br />8F24-1B/1T 8F24-0B/1T © " "=77 Co cretemasonryunitseand8"to 11" erASslump. 2. Contractor to provide proper protection of lintel to prevent rusting. 1-THIS PLAN IS TO BE USED FOR STRUCTURAL INFORMATION <br />' , • ' • • •. Concrete mason units CMU r ASTM C90 w/--- <br />Refer <br />masonry ( ) � to manufacturer's specifications. <br />O O • • • .•;;' • ♦- •; • • minimum net area compressive strength = 1900 psi. 3. If lintel is scratched or damaged refer to Powers Steel for repair. ONLY. �! <br />,: ' •• 6tebar per ASTM A615 Grade 60. <br />,' Q' . ,; . •" , 4. Lintel depth to match recast depth. One #5 Bar required top and <br />0 0 0 0 ' '' • ;'.., , Prestressing strand per ASTM A416 grade bottom of all Powers Steel lintelsp 2- UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE TO BE B D. <br />' ' 230 low relaxation. u ! <br />8F32 OB/1 T 8F32 1 B/1 T 5. A bonding agent must be applied to the Steel Box lintels prior to <br />7/32 wire per ASTM A510. applying the cementitiuos coating. See contractor specifications ASSUMED TO B E 16 MINIMUM DEPTH. ti, , I , <br />., Mortar per ASTM C270 type M or S. — � <br />'; o; , b;; •, �;; ® ® 3- THE NUMBER OF COURSES OF MASONRY `� �'' <br />GENERAL INSTALLATION NOTES SO Y REQUIRED BETWEEN 4 `r >~ F•• N 6,�' <br />• o o - THE LINTEL & THE BOND BEAM SHOULD BE COORDINATED WITH Z <br />•: •, , •- .., ♦ •, • ♦ • 1. Provide full mortar head and bed joints. Z <br />•, . <br />. , :; . ; , , • ,, , ; : , • 8F40 OB/1 T Q' 2. Shore filled lintels as required. <br />• ' , o 0 3. Installation of lintel must comply with the architectural and/or structural drawings. THE ELEVATION DRAWINGS <br />® 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate A L� a e w •" u' <br />8F44 1B/1T vertical cell reinforcing and grouting. - 4- THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING - � < `'` .�O-Z <br />,'; ; •'; 5, All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and <br />• ® longer with a nominal height of 8" meet or exceed L11 80. <br />THE PROPER LINTEL HEIGHT. Z •• © . <br />:• •' 6. Bottom field added rebartobelocated atthe bottom ofthe liintelcavity. 5- LINTELS AT GARAGE DOOR OPENING ARE MINIMUM DEPTH •, = `` ' m <br />:.':', • ,' 7. 7132" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />••' ''• •' g, Cast -in -place concrete may be provided in composite lintel in lieu of concrete REQUIRED FOR THE DESIGN LOADS. THE DEPTH MAY BE <br />` •• - • . ` - ' ' • ` ;' masonry units. - f/f• , <br />9. Safe load ratings based on rational design analysis per AC1318and AC1530 INCREASED IF REQUIRED FOR PROPER LINTEL HEIGHT,G.C. <br />;; • r �, �, _ � ; ; , � ;; 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />' 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have COORDINATE. <br />• ` • • • • •' •' a coating of stucco applied in accordance with ASTM C-926 or other approved To the best of the Engineer's knowledge, information, and <br />;•; �; ;;• • •:• ; •: coating. <br />• '' • O 01 <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />•.' • O ' " O loads shoud be checked for combine loading with the following equation: POWER STEEL LINTEL I S AN ADEQUATE Code al Edition f r the Residential. Engineer's signature <br />. ; • 8F28 1 B/1 T , Applied vertical load Applied horizontal load and seal is only for the structural engineering portions of <br />• ` 8F28 OB/1 T O O the drawing pages bearing Engineer's signature and seal. <br />SO O 8RF3016/1T Safe vertical load '}Safehorizontalload < 1.0 SUBSTITUTION a" ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />o O <br />8RF40( 0BB/1T <br />O <br />Z N <br />O1-4 <br />tv <br />Q�-�MU) <br />a (A •� �' <br />Q W—Ln <br />a <br />E - �U <br />O - Q - CL 00 <br />Wow <br />_ W J� <br />Cn <br />FO A <br />O D <br />O O <br />O J <br />A EO <br />O .. ........... . . <br />E <br />O f <br />0 <br />LL <br />LU p� <br />CAST CRETE LINTEL o Z a <br />IS REQ/D. NO POWER <br />STEEL cn � o � W <br />MIN. M 84 sz <br />IC)z® <br />MIN. <br />ST CRETE LINTEL Ln <br />REQ/D. NO POWER r-4 <br />STEEL <br />,—t <br />Q Zo <br />Ve <br />Q� <br />o o z Wa�0 <br />F - o o) LL1 I— Z~� f 58 <br />-' $�0 Z <br />o o o 0 0 0 M T'r'I Z o <br />I-- ao ao 1- I : 60 00 H O M J uj <br />LIJ <br />a� <br />p o o p Z.. <br />~ 00 0o H W �••— Z Z <br />E Q Q V <br />zoo J O a c <br />MIN. r <br />MIN N. MIN. SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAMES <br />O VERSION NO. <br />O O E E <br />1122 <br />O O <br />J06 No: 17-4137 <br />LINTEL PLAN F& G LINTEL PLAN D SHEET NO. <br />LINTEL PLAN A, B & C <br />SCALE: Y4"=1'-0" SCALE: Y4'=1'-0" L 1 <br />SCALE: Ya"=1'-0" <br />