Laserfiche WebLink
— — -I <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" it <br />STUB -OUT FOR O 1'-0" o ;n <br />GAS METER <br />0 0_ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'4" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'41 <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 USP HTW20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'4" <br />1 USP HTW20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />V-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />151-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE v, <br />15/32" CDX <br />m <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR Sd RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAYBE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />0 ur) a <br />-#- t .h t t t t + t + + t + + + + + <br />6'-0" + 6'-0"U) C <br />+ + + + <br />+ + + <br />+ + <br />+ + t + h + <br />+tl + + + + ++t+ <br />+ + + + + + + + + + t <br />+ h + + + + Z++ <br />++ + + + ++ + + + + + + + + + + + + + <br />+++ ++++++++ + <br />z CL <br />fo <br />Q� U a z <br />zW <br />480, <br />0*1 <br />v <br />10 <br />Backer and Filler Block Dimensions <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL <br />kn <br />cc <br />CONT. #5 > STD. 90° <br />BAR I HOOK <br />STD. 900 HOOK r— BOND BEAM <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN Y <br />SEE PLAN FOR REQ'D—PLYWOOD FLOOR <br />COLUMN AND J%.% -= SHEATHING PER PLAN <br />CONNECTION r J <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION a@ INT. BRIG. WALL <br />N.T.S. <br />Y <br />1/8" min. }Small gap 2' min. <br />+ i 2" max. 4 max.-- - <br />x i Web Stiffener Fastener Schedule_ _.._ <br />Joist Bearin Location <br />i <br />Series Depth End Intermediate <br />BCI 5000s® 111--7/8," 2-8d M-d -- <br />Clinch nails 1/ 2-8d -8d <br />-- _ - <br />- <br />when BCI 6000s@ 11-7/8 2 8 3-8d <br />possible @' 14" 2-8d 5-8d — <br />BCI 6500s <br />1) Support back of web during nailing to prevent damage to 16" 2-8d 6-8d <br />11-7/8" 2-8d 3-8d <br />web -flange connection. --- -- BCI 60s@ 14" 2-8d - _ 5-8d <br />2) Block solid between joists for full length of span. Tight fit - Q 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-7/ " 3-16d 3-16d____ _ <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. BCI 90s@ 14" 5-1 5-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4" max. ! 16" 1 6-1bd ] 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP TOP sides b 6". - Hangers with side nailing. <br />@ Y -Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flangeuthcuis. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />BEARING Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer Plumbing <br />Vertical load transfer =1900 plf max along load bearing wall. �r' Load bearing walls when load bearing - for lateral support when joists <br />Load bearing wall must stack '" �1 meet over wall, or wall stacks directly over wall or <br />over squash=20 blocks and /� beam below Load bearing wall must stack over I <br />Non -stacking walls wall or beam below.* = blocking and wall or beam below.* require additional Joist <br />consideration. Check Z' <br />local building When joists meet over wall, provide <br />code for appropriate 13/4" minimum bearing for each, I Joist can be offset <br />details in One 10d box up to 3 to avoid <br />vertical plumbing <br />areas=20 of high or-20 sinker P g <br />3" max <br />lateral load. %�� � ii �; �.' <br />nail each side i <br />at bearing. JOISTS OFFSET <br />.'j N.T.S. <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />Squash block 10d nails SECTION � I NT. BRIG. WALL require additional consideration. <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam OD <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />i <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />6" A " ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT OUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />8 <br />V-0" <br />1'-1" <br />1'-2" <br />1' 2" <br />V-3" <br />V-3" <br />V-7" <br />1'-11" <br />2'-4" <br />7-9-3'-2" <br />3'-7" <br />_ __ __ <br />16" joist 12 <br />1'-0- <br />V-1" <br />1'-2- <br />V-2" <br />V-3" <br />1'-9" <br />2'4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'4" <br />— ^ Span (tt) 16 <br />V-0" <br />V-1" <br />1'-2" <br />V-2" <br />V-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />T-2" <br />_- <br />20 <br />1'-0" <br />V-1" <br />1'-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'40" <br />5'-11" <br />---�---------- -{ 24 <br />V-0" <br />V-1" <br />1'-2" <br />T-3" <br />2'-5" <br />3'-7- <br />4'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE, THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />A <br />USP <br />MUGT15 TYP. GIRDER TRUSS <br />7� _- r 2X TOP PLATE <br />5/8"0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />MUGT15 TYP. <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION_ <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 /HTA 20 <br />INSTALLATION <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />a <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d A 1/2" NAILS <br />UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />• iA <br />-- <br />� i �Il�ll�ll� <br />Cm <br />u'�ii Il�lls�il�hll �':,n.11.�ll �� Ilirl�I�L>t <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. • ' <br />j SLEEVE THRU STEM <br />SEE PLAN FOR •. • . • . • <br />FOUNDATION INFO 4 4' <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />�% ` Filler block. <br />\ Nail with <br />10-10d nails. <br />Backer block required where top a „ � <br />mount hanger load exceeds 250 lbs. a . <br />Install tight to top flange. �•� <br />IItLL`IIC 4 •' 4a <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />-1 requirements <br />! � 0.6 X Joist <br />o I�depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />i <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a4: 4 <br />c2I \' • a • <br />�c14 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />G . ° / . as L <br />a G <br />A O 4 <br />e I� <br />SEE FND. PLN. <br />SIZE & REINF. <br />Z�®z <br />z <br />tl <br />t,/) U <br />� w <br />0 w <br />~ m n <br />U rNi M <br />w <br />U <br />Q � Lo o <br />B �D. <br />SE a <br />To the best of ngln is k DwledgwlA ormqq��Tian, <br />belief, the struct la fS���,nd s� Ificatlgrf6lneA <br />within these drawl f➢�n1�18 � lands.\```` <br />Building Code - Resld2Apy44Lh Edition. Engl \' <br />signature and seal Is only-f tlj qq�! nearing <br />portions of the drawln {�yd E7�Qj g pages bea}M neer's signature <br />and seal. <br />11 <br />O <br />Z N <br />t>iV)MO <br />M <br />Q � COZ § � <br />W <br />J � <br />� <br />8J <br />&YI <br />" w <br />O •_ � � �W <br />_ V ou. <br />Q W <br />Z N <br />N <br />L1•) Z Z <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAND <br />VERSION NO. <br />O <br />SHEET N0. <br />SN 1 <br />