Laserfiche WebLink
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />N <br />T.O.M. <br />HDR HGT. <br />6" FASCIA <br />(TYP) <br />TEXTURED — <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />F.FL. <br />12 <br />1 J <br />5� �- --' I r <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />1' 0" <br />---�— -- ------------------ <br />F1 _71 17 - - 0 1: 1 D F1 7--1 [ED L I RE <br />1:1 L-1 11 EI ELDI-E-1- E-1 LJ <br />FEI LD-1 El E 11 IL71 1:1 <br />12 <br />12 <br />14'-0" RIDGE VENT <br />---------------------HEEL <br />— F4 T.O.M. <br />— HDR HGT. <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) °0 <br />c0 <br />---F.FL. <br />O <br />-v <br />N <br />-------------------------------------- ------------------------- - ---------------------------------------------------- <br />FRONT ELEVATION - Al <br />SCALE: 1l4'=1'-0' <br />2'-0" <br />RIGHT ELEVATION - Al <br />1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />0 PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />(Sq. Ft. SofIN Needed) x 7 = (Sq. In. Needed) 172 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)19 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />..Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of allagin Vents Needed <br />Z�®z <br />z <br />a <br />w <br />M p <br />O t-" <br />U <br />w <br />'M <br />c�r <br />O <br />fLL� <br />in <br />B <br />D. <br />z 4P2 <br />LL c 5 <br />co <br />Q <br />'✓ R <br />a-b <br />To the best of the Englne4i4iR/�owledge, Infor a�t�q�;and <br />belief, the structural plans ant- Aed <br />within these drawings comply with:Ielg 7 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z N <br />Q � N <br />t>�M iO <br />M <br />Q M Ln <br />Q�� <br />F- <br />v a <br />a 00 <br />W <br />E� <br />zM <br />J� <br />J <br />W <br />ii <br />Fm <br />Fm <br />CQ <br />Z� <br />U <br />O <br />� J <br />J <br />JH <br />go <br />T­4 <br />LU <br />ry <br />O <br />o <br />> <br />C: <br />z <br />fu <br />Z <br />N' <br />cot <br />Botg <br />01a_N <br />LL <br />�* <br />z <br />d' <br />< W <br />J <br />N <br />Ln <br />rl <br />Lli <br />Q <br />Z <br />z <br />t <br />fi <br />g <br />cD <br />'n <br />m <br />06 <br />� <br />_ <br />rn <br />� <br />a <br />fn <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAND <br />VERSION NO' 10 <br />SHEET NO. <br />3.1 <br />