ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />for" <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />-q)4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q% <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />D <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14. 250.94 <br />200A <br />INDOOR PANEL <br />CENTER <br />014 copper to lights E outlets <br />200 AMP 1 <br />00 A <br />M72 cropper to 20 amp clas <br />00 a10.2 copper to WH <br />01 7M10.3 copper to Dryer <br />METER <br />MO2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nt-n ont-no <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />—r. <br />W.H. VERIFY LOCATION <br />TELEPHONE (OPTIONAL) <br />GFI <br />----- -----J <br />ELECTRICAL PANEL <br />® <br />TELEVISION (OPTIONAL) <br />1111111711111111111 <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />REC <br />VERIFY METER <br />FOR ALARM <br />SYSTEM WITH <br />O <br />THERMOSTAT <br />BUUILDEIRN <br />ELECTRIC METER <br />man <br />ELECTRIC PANEL <br />_ <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4°=1 t-0° <br />u')W <br />z <br />z� <br />z <br />Q <br />a <br />:V) (D <br />W <br />cn <br />'~ w <br />Q <br />.0 <br />— <br />O c <br />E <br />C O <br />v J <br />U <br />CO r+ <br />I-u <br />= y <br />W <br />M <br />125 <br />0 <br />LL <br />L� <br />� <br />Q <br />Ci <br />o� cj �' Z <br />inzor- <br />P1 <br />` o <br />_ 4 W <br />W ` R u' <br />i.VA <br />Z <- f <br />O <br />�m <br />LLa� m Co <br />00 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />0 <br />Z n4 <br />0 � � <br />V) O <br />M <br />Q (,n 'Mp Ln <br />a Ln•��' <br />F— !v � ll) <br />a <br />DC U a <br />0000 <br />Q C <br />W <br />Z M <br />J 0 <br />�a <br />z <br />���gg�qg�jja <br />Z <br />U <br />T—I <br />U <br />uno <br />U <br />�_ <br />O <br />W <br />fu <br />IM <br />W <br />OU <br />�_ <br />� <br />QW <br />a <br />ea.a� <br />O <br />U <br />g <br />Z <br />ogg <br />� <br />G <br />�R�3 <br />Cr• <br />J <br />Ln <br />I-•1 <br />I LU <br />fi <br />M <br />Q <br />z <br />Im <br />O <br />00 <br />ZLU <br />g <br />= <br />,.4 <br />a <br />Ln <br />Z <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAND <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />