My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6635 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6635 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:40:50 PM
Creation date
2/27/2025 1:12:08 PM
Metadata
Fields
Template:
Building Plans
Street #
6635
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I <br />I <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />- - - - - - - - - - - - - - - - - - - - - - - - -- --------------- - - - - - - <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY' <br />BON <br />TERMINATIOP <br />NEC 08, 250.94 J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Dpper to lights & outlets <br />Doper to 20 amp ckts <br />A/C PAD <br />copper to WH <br />copper to Dryer <br />WP <br />DISC. GFI <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />$4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />�t®) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />P.C. <br />TRACK LIGHT <br />- <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />J <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />-1 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />`0) <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />IT 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />T� <br />THERMOSTAT <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />fh� <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />EM <br />(1) PHONE LINE, (1) DATA PORT <br />JII 3" VTR <br />I � I <br />I I 2" VTR III <br />I <br />SINK I I KITCHEN <br />SINK W/ STUDOR <br />- 31, ,III 2" VTR I I �, <br />I WC 3" I <br />TUB 3„ 1 <br />L SHWR 3�� J SINK I I <br />1.5" VTR Ill, 3rr 2, <br />I I I <br />'I I I I WC <br />I 31' - <br />r 3" I <br />TUB <br />311 SINK <br />3r, I I <br />- I <br />HANSON BOX WC <br />4" TUB <br />4" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR 1 1 ' Q <br />DISPOSAL I G <br />FI 2 X 4 FL. GFI <br />UNDER q i i —� 1 I <br />CNTR TOP J <br />�I L-0 i <br />I I I I IS <br />PENDANT <br />PENDANT 2 X 4 FL. GFI <br />LIGHTS OVER I <br />ISLAND <br />I <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />OPTIONAL LIGHTING <br />C/O <br />1 <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />r _ -I <br />I ALT. III <br />I� A/C �I <br />PAD <br />rr-AC-MrfC PAO rCr{ { } <br />�. SPECS I�TJ <br />ELECTRICAL PLAN - <br />SCALE: %4"=V-0" <br />U') <br />U <br />Z o <br />Z <br />Q <br />J <br />a <br />V) tJ <br />W C <br />4--J W <br />•U — <br />LU <br />O C <br />= <br />'m <br />~ <br />y <br />(n <br />O o <br />TS ~ <br />m I- <br />W <br />— $ <br />W ® H <br />C W M <br />N 'O M <br />O Oo <br />_ <br />D <br />UN <br />. <br />M �D <br />� to <br />171.1 <br />k <br />Q°of <br />rn ov <br />�i¢o <br />A' <br />Nl'BL C <br />r` <br />CO N <br />�A <br />t0 <br />c .- <br />0 1 <br />o � <br />Ci <br />Z (V <br />�rZ F r M 1 <br />ii rn ILL <br />W4 <br />...1 Z <br />J <br />W LL <br />CLa <br />O0 <br />� C N (j <br />y�2-2 <br />0 <br />m <br />LLZ <br />a <br />o <br />p <br />W <04S <br />CV <br />� <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z cV <br />O n <br />.2 <br />M <br />I,-,U) O <br />M <br />Q U-) -gyp <br />V) •L <br />d' <br />•cj <br />i� U p_ " r <br />O <br />Q <br />Z E <br />J~ � <br />W <br />J <br />f <br />Oz <br />ad <br />W ZILA <br />a <br />ulm -i0 <br />or- ¢U <br />lZ-->-aCJ�Q <br />2�Zw1'Z <br />uj -i <br />Q � <br />(> <br />d5 W N <br />r-I <br />d- <br />w Z <br />W <br />O <br />L,ri <br />N <br />Ll) <br />ri <br />J <br />W O 3 <br />e.."% Z <br />W tttIIISSS V <br />0 O W <br />v W <br />O <br />-0 <br />Q <br />Z <br />Q Q <br />J <br />�I-m2 <br />Z <br />zgu.jow <br />f0 <br />Z <br />^ <br />{.ia, <br />LU <br />J!� <br />// <br />owoZ�o <br />Q~� W 2 <br />toms$$ ~G. <br />WO zQ <br /><ao8 <br />�- <br />Ce <br />Ln <br />N <br />zo <br />N � <br />J Q W ¢ <br />O <br />T-q� <br />� � <br />J tY Y W <br />¢Q�ILL <br />Z <br />> <br />0 <br />w <br />g J <br />Z <br />a W <br />14SCALE <br />-j <br />: AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAM ES <br />VERSION NO. <br />106 <br />JOB NO: 17-5177 <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.