My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7852 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7852 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:45:24 PM
Creation date
2/27/2025 1:12:20 PM
Metadata
Fields
Template:
Building Plans
Street #
7852
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2393
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- <br />)ocuSign Envelope ID: 936C32D4-E265-4FOA-B8BD-0127630741AA <br />EXISTING EXTERIOR CMU I� p <br />- L <br />MIN. 3" EDGE DISTANCE r <br />STRIP OF WWF FROM F.F.E. TO - �v <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ Fl ° p ° D - -D <br />(2) ROWS OF 3/6" DIA. TAPCONS / <br />OR CUT NAILS @ 24" O.C. COVER p ° <br />FLUSH w/ 3000psi CONCRETE. % <br />EXISTING FOUNDATION. <br />D � <br />°I o <br />I ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL I <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANT, ° <br />STRIP OF WWF FROM F.F.E. TO -- <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ ° - - - - - - <br />(2) ROWS OF 3/" 6DIA. TAPCONS D <br />OR CUT NAILS @ 24" O.C. COVER p o <br />FLUSH w/ 3000psi CONCRETE. i <br />° EXISTING FOUNDATION <br />D � <br />p D <br />D \ <br />I ° <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />(MAX 20" <br />a a d <br />j\\ \\ /\" d - Q <br />//\/�\\�\\/\\ <br />DEEP) <br />a d <br />4 <br />a ° <br />4" EXTENSION <br />UNDER BRICK VENEER <br />1 12" UNDER 1 STORY WALL <br />VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />in <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />d - <br />4 <br />d <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWALL MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" 7' <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />cn J - -d- <br />U) o d ° ° $ , °d ° #4 OR #5 <br />=O U) ° ° ° REINFORCING PER <br />U Q d ° ° MONOLITHIC FOOTING <br />R of ° ° ° ° d SECTION <br />° FOOTING TO BEAR ON FIRM <br />d° ° UNDISTURBED SOIL <br />d ° d <br />//�\//\\//\\//\\//�%\\//\\�/ %\'/\�/\\'/" <br />`- • STEMWALL FOOTING TO EXTEND MIN <br />BELOW <br />A <br />*ADDITIONAL #4 OR #5 VERTICAL TO <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />/\ <br />_ U) <br />O <br />U <br />VAPOR BARRIER -- //\// <br />W w <br />LUIp <br />#4 OR #5 VERT REINFORCING\�� <br />UP TO 3 COURSES: 72" O.C.\/\\ <br />4 TO 5 COURSES: 48" O.C./�/ <br />_/ /\\ \ ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT OPT BRICK LEDGE <br />N <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE - w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 Q U J (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q cn CONT <br />Lu . s ~ w <br />FINISH <br />O GRADE <br />\��\\ \\ \\ \\ \\ �\ j�\\ w • F \/\\\ \\ X x \\\ <br />A//`\/�\\i\\\/�-/\� < <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. \ - ° ': \/\\ <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM - <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM 4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT: <br />36" MAX VARIES PER <br />�- ARCH PLANS <br />12" MIN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/2" CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90° BEND @ 48" O.C. <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />12" UNDER 1 STORY WALL W(2)I <br />ADDITIONAL NO.4 OR NO. 5 �#4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE L <br />16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE* IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a, U <br />p <br />\ \ \ \ \ \ 1 ALL OTHER EXTERIOR WALL `N Ocy <br />CLADDING - MIN 8", U.N.O. ON ARCH O p <br />04 APE�0 <br />VAPOR BARRIER `// ° \\ \\ \\ \\ \\ \\ \ <br />12" MIN \AAAA//A� � � <br />xxxxxx%\\\\ O x <br />FOOTING TO BEAR ON \ <br />FIRM UNDISTURBED 6" OPT. EXTENSION IN BRICK <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J a, <br />BAR IN BRICK LEDGE IL <br />16" UNDER 2 STORY WALL w/ Ld <br />(2) #5 OR (3) #4 CONTINUOUS tds J Q <br />trup design studios � <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-O" VERTICALLY O <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O .,- <br />co <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W _ <br />FIBERMESH <br />- -- a ~ • <br />NN <br />Cn <br />-- • <br />:3 <br />m �a` 'tg`=``\ a <br />16" VAPOR BARRIER Q e <br />d <br />3 BEARING WALL FOOTING SECTION U <br />z <br />w <br />0 <br />w <br />CONCRETE SLAB W/ 6x6 0Y <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />_ SEE ARCH 0) <br />a a \ \ Q d DETAILS <br />LO <br />r- >= <br />8" MIN O V J <br />8"x8" THICKENED 8" (1) <br />FTG AT U) <br />STEP-DOWN, SEE VAPOR BARRIER W <br />PLAN U Z W <br />4 CURB STEP SECTION m LU 0 Cn <br />- 11 1 W Q <br />W Q 0 <br />8" UNDER MASONRY WALL ! Z <br />F__ -- V > Q <br />CONCRETE SLAB W/ i 6" UNDER WOOD WALL Z M <br />6x6 W1.4 x W1.4 WWF - _- w W 0 <br />OR FIBERMESH ° <br />W <br />VARIES � � SEE ARCH 0 p � � 2 <br />- �- - - n- , 1 (MAX 16") <br />dot 0 / <br />W X <br />12" M I N OVA/AA/VA/VA/V� Z <br />VAPOR BARRIER <br />6" OPT. EXTENSION IN BRICK 0 W <br />1 LOCATIONS ON FND PLAN a Z <br />UNDER 1 STORY WALL w/ 1 0 <br />O a. <br />t5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL JI BAR IN BRICK LEDGE - <br />UNDER 2 STORY WALL w/ Q w <br />r5 OR (3) #4 CONTINUOUS ABBOTT PARK Q <br />GARAGE EX_T WALL CURB SECTION O U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LLI <br />LOT 023-01 0 <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 0 < <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z Z <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY 0 <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. U) <br />PROJECT NO w <br />CONCRETE SLAB W/ 6x6 O 2021.006622 0 <br />W1.4 x W1.4 WWF OR 0 LL <br />FIBERMESH Z DRAWN: O <br />0'-0"A.F.F. SEEARCH a:KME 810 <br />U <br />d W (MAX 20" O <br />° a ° � DEEP) � CHKD: <br />\/\/\ a _ Q a ° x MJP <br />a <br />\\\a a 4" w J <br />EXTENSION <br />UNDER BRICK VENEER ��,�(1N 1 BAN �,��� U) <br />12" UNDER 1 STORY WALL } ����5' (,•E N ' /F'4 �� � <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : .•'� SF•••• �� Z <br />16" UNDER 2 STORY WALL * NO 85166 * Q <br />wl / (3) #4 OR (2) #5 CONT Z _ DO Signed by: M <br />6 BEARING CURB STEP SECTION w TDAFa3S�IJJ <br />���'SS�O <br />z N AL E'S <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />O_ 05-17-2021 p <br />H W <br />U REVISIONS: LIJ <br />Q No. Description Date ~ <br />W <br />U) J <br />O I- <br />O Z <br />2 O <br />0 <br />U <br />w <br />x W ST=2mD <br />d <br />CMU/METAL CONNECTOR ENGINEERING <br />_/ /\\ \ ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT OPT BRICK LEDGE <br />N <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE - w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 Q U J (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q cn CONT <br />Lu . s ~ w <br />FINISH <br />O GRADE <br />\��\\ \\ \\ \\ \\ �\ j�\\ w • F \/\\\ \\ X x \\\ <br />A//`\/�\\i\\\/�-/\� < <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. \ - ° ': \/\\ <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM - <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM 4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT: <br />36" MAX VARIES PER <br />�- ARCH PLANS <br />12" MIN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/2" CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90° BEND @ 48" O.C. <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />12" UNDER 1 STORY WALL W(2)I <br />ADDITIONAL NO.4 OR NO. 5 �#4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE L <br />16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE* IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a, U <br />p <br />\ \ \ \ \ \ 1 ALL OTHER EXTERIOR WALL `N Ocy <br />CLADDING - MIN 8", U.N.O. ON ARCH O p <br />04 APE�0 <br />VAPOR BARRIER `// ° \\ \\ \\ \\ \\ \\ \ <br />12" MIN \AAAA//A� � � <br />xxxxxx%\\\\ O x <br />FOOTING TO BEAR ON \ <br />FIRM UNDISTURBED 6" OPT. EXTENSION IN BRICK <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J a, <br />BAR IN BRICK LEDGE IL <br />16" UNDER 2 STORY WALL w/ Ld <br />(2) #5 OR (3) #4 CONTINUOUS tds J Q <br />trup design studios � <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-O" VERTICALLY O <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O .,- <br />co <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W _ <br />FIBERMESH <br />- -- a ~ • <br />NN <br />Cn <br />-- • <br />:3 <br />m �a` 'tg`=``\ a <br />16" VAPOR BARRIER Q e <br />d <br />3 BEARING WALL FOOTING SECTION U <br />z <br />w <br />0 <br />w <br />CONCRETE SLAB W/ 6x6 0Y <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />_ SEE ARCH 0) <br />a a \ \ Q d DETAILS <br />LO <br />r- >= <br />8" MIN O V J <br />8"x8" THICKENED 8" (1) <br />FTG AT U) <br />STEP-DOWN, SEE VAPOR BARRIER W <br />PLAN U Z W <br />4 CURB STEP SECTION m LU 0 Cn <br />- 11 1 W Q <br />W Q 0 <br />8" UNDER MASONRY WALL ! Z <br />F__ -- V > Q <br />CONCRETE SLAB W/ i 6" UNDER WOOD WALL Z M <br />6x6 W1.4 x W1.4 WWF - _- w W 0 <br />OR FIBERMESH ° <br />W <br />VARIES � � SEE ARCH 0 p � � 2 <br />- �- - - n- , 1 (MAX 16") <br />dot 0 / <br />W X <br />12" M I N OVA/AA/VA/VA/V� Z <br />VAPOR BARRIER <br />6" OPT. EXTENSION IN BRICK 0 W <br />1 LOCATIONS ON FND PLAN a Z <br />UNDER 1 STORY WALL w/ 1 0 <br />O a. <br />t5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL JI BAR IN BRICK LEDGE - <br />UNDER 2 STORY WALL w/ Q w <br />r5 OR (3) #4 CONTINUOUS ABBOTT PARK Q <br />GARAGE EX_T WALL CURB SECTION O U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LLI <br />LOT 023-01 0 <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 0 < <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z Z <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY 0 <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. U) <br />PROJECT NO w <br />CONCRETE SLAB W/ 6x6 O 2021.006622 0 <br />W1.4 x W1.4 WWF OR 0 LL <br />FIBERMESH Z DRAWN: O <br />0'-0"A.F.F. SEEARCH a:KME 810 <br />U <br />d W (MAX 20" O <br />° a ° � DEEP) � CHKD: <br />\/\/\ a _ Q a ° x MJP <br />a <br />\\\a a 4" w J <br />EXTENSION <br />UNDER BRICK VENEER ��,�(1N 1 BAN �,��� U) <br />12" UNDER 1 STORY WALL } ����5' (,•E N ' /F'4 �� � <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : .•'� SF•••• �� Z <br />16" UNDER 2 STORY WALL * NO 85166 * Q <br />wl / (3) #4 OR (2) #5 CONT Z _ DO Signed by: M <br />6 BEARING CURB STEP SECTION w TDAFa3S�IJJ <br />���'SS�O <br />z N AL E'S <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />O_ 05-17-2021 p <br />H W <br />U REVISIONS: LIJ <br />Q No. Description Date ~ <br />W <br />U) J <br />O I- <br />O Z <br />2 O <br />0 <br />U <br />w <br />x W ST=2mD <br />d <br />CMU/METAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.