Laserfiche WebLink
)ocuSign Envelope ID: 936C32D4-E265-4FOA-B8BD-0127630741AA <br />1/2" (MIN) STI. <br />FINISH TEXTI <br />PER COMMUI <br />SPECIFCATIC <br />FLANGE CASI <br />BEAD <br />CASING BEAD at WN <br />SCALE: N.T.S. <br />5/8" CEMENT PLASTER <br />12" WIDE SELF-ADHESIVE <br />FLASHING CENTERED UNDER <br />CONTROL JOINT (CLEAN <br />MASONRY BEFORE APPLYING) <br />PRE -FORMED CONTROL <br />JOINT W/ STRIP LATH <br />CONTROL JOINT - HORIZ - CMU <br />SCALE: N.T.S. <br />VINYL ANGLED <br />CASING BEAD <br />(AM66-ANGLED-1250) <br />z <br />z <br />0 <br />a <br />(D J <br />w <br />VINYL CASING <br />BEAD (AM66-1250) <br />1/2" (MIN) TEXTURED <br />FINISH at MASONRY <br />RAISED BAND at BLOCK <br />SCALE: N.T.S. <br />tie" GYP BRD OVER <br />PRE -SHAPED STUCCO BAND <br />1x2 TREATED <br />W/ SLID TOP INSTALLED PER <br />FURRING STRIPS <br />- <br />MFR WRITTEN SPECS (RE: <br />at CMU WALL (TYP) <br />ELEV) <br />SELF ADHESIVE -OR- FLUID <br />APPLIED FLASHING (CLEAN <br />MASONRY BEFORE APPLYING) <br />PT 1x WOOD BUCK <br />VINYL FLANGE CASING BEAD <br />SHIM AS NEEDED <br />INSTALLED PER MFR <br />WRITTEN SPECS (TYP) <br />48" BACKER ROD W/ SEALANT <br />INTERIOR <br />EXTERIOR <br />WINDOW HEAD <br />at CMU <br />SCALE: 1 �2" = 1'-0" <br />PRE -FORMED CONTROL / <br />JOINT W/ STRIP LATH 5/8" CEMENT PLASTER <br />12" WIDE SELF-ADHESIVE <br />FLASHING CENTERED UNDER <br />x*� =«• CONTROL JOINT (CLEAN <br />MASONRY BEFORE APPLYING) <br />_T \ <br />CONTROL JOINT - VERTICAL - CMU <br />SCALE: N.T.S. <br />2 1/2 <br />CORNER BEAD <br />(FASTENER & <br />SPACING at 7" O.C.) <br />;MU <br />112" (MIN) STUCCO FINISH <br />f EXTURED PER COMMUNITY <br />3PECIFCATIONS <br />CORNER BEAD at BLOCK <br />SCALE: N.T.S. <br />` CMU WALL W/ <br />STUCCO FINISH <br />P....:. <br />:. <br />(RE: STRUCTURAL) <br />GYP BRD OVER <br />PRE -SHAPED STUCCO BAND <br />1x2 TREATED <br />W/ INSTALLED PER MFR <br />FURRING STRIPS <br />WRITTEN SPECS (RE: ELEV) <br />at CMU WALL (TYP) <br />WOOD BLOCKIN <br />SELF ADHESIVE -OR- FLUID <br />APPLIED FLASHING (CLEAN <br />r <br />MASONRY BEFORE APPLYING) <br />PT 1x WOOD BUCK <br />VINYL FLANGE CASING BEAD <br />SHIM AS NEEDED <br />INSTALLED PER MFR <br />WRITTEN SPECS (TYP) <br />- <br />48" BACKER ROD W/ SEALANT <br />INTERIOR <br />EXTERIOR <br />WINDOW JAMB <br />at CMU <br />SCALE: 1 ti2" = 1'-0" <br />6" SELF -ADHERING <br />FLASHING <br />WEATHER RESISTIVE <br />BARRIER #1 <br />WEATHER RESISTIVE <br />BARRIER #2 <br />STUCCO FINISH <br />6" SELF ADHESIVE <br />OVER TOP & SIDES <br />SELF FLASHING <br />UNIT <br />PREMANUF. <br />DRYER VENT CAP <br />(SET IN CONT. <br />SEALANT) <br />SEALANT at <br />TOP & SIDES <br />DRYER VENT (BLOCK) <br />SCALE: N.T.S. <br />a\\ <br />Q <br />C� <br />v <br />6" SELF -ADHERING c / <br />FLASHING <br />GALV'D METALXLi <br />— <br />"Z" FLASHING <br />DO NOT CAULK OR <br />SEAL OPENING <br />1 1/4" X 6" SIMULATED / <br />WOOD TRIM MEMBER <br />SEAL GAP W/ CAULKING <br />OR APPROVED SEALANT <br />I <br />STUCCO CASING BEAD <br />SIDING TO STUCCO <br />FRAME TO BLOCK <br />SELF ADHESIVE -OR- FLUID <br />APPLIED PAN FLASHING (CLEAN <br />MASONRY BEFORE APPLYING) <br />EXTEND UP AT JAMBS (4" MIN) <br />PRECAST CONCRETE SILL <br />�8" BACKER ROD W/ SEALANT <br />VINYL FLANGE CASING BEAD <br />GYP BRD OVER <br />"::I <br />INSTALLED PER MFR <br />1x2 TREATED <br />WRITTEN SPECS (TYP) <br />FURRING STRIPS <br />CMU STEMWALL W/ <br />at CMU WALL (TYP) <br />§8" STUCCO FINISH <br />(RE: STRUCTURAL) <br />INTERIOR <br />EXTERIOR <br />WINDOW SILL <br />at CMU <br />SCALE: 1 y2" = 1'-0" <br />ELECTRIC ME - <br />FIELD VERIFY <br />LOCATION <br />AREA TO RECE, <br />STUCCO SCRATCH COAT <br />& 1 COAT OF PAINT W/ <br />BACK -ROLL PRIOR TO <br />ELECTRIC METER <br />INSTALLATION <br />ELECTRICAL CONDUIT PENETRATION <br />WOOD CONST BEYOND <br />WOOD SHEATHING <br />WEATHER RESISTIVE <br />BARRIER #1 <br />WEATHER RESISTIVE <br />BARRIER #2 <br />5/16" X 7 114" LAP <br />SIDING W/ 6 REVEAL <br />STARTER STRIP <br />DO NOT CAULK OR <br />SEAL OPENING <br />GALV'D METAL "Z" <br />FLASHING <br />1 1/4" X 6" SIMULATED <br />WOOD TRIM MEMBER <br />STUCCO <br />CASING BEAD <br />SCALE: N.T.S. <br />GYP BRD OVER — <br />1 x2 TREATED <br />FURRING STRIPS <br />at CMU WALL (TYP) <br />PT 1x4 <br />PT 2x4 FRAME ANCHOR <br />SHIM AS NEEDED <br />INTERIOR <br />WD SHE, <br />(RE:STF <br />DNE (1) <br />ELECTRIC <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEN <br />FOAM ("GREAT STUFF" OR <br />SIMILAR) <br />APPLY A SILICON BASE <br />SEALANT AT POINT THAT <br />ELEC WIRE PENETRATES <br />PROVIDE STUCCO <br />SCRATCH COAT LARGER <br />THAN THE ELECTRIC <br />METER CAN OR METER <br />CAN COMBO OR METER <br />CAN AND DISCONNECT <br />SCALE: N.T.S. <br />FIBERCEMENT -OR- VINYL LAP <br />SIDING OVER APPROVED <br />HOUSEWRAP INSTALLED PER <br />FINISH COATING OVER PRIMED <br />MFR WRITTEN SPECIFICATIONS <br />THREE COAT STUCCO FINISH <br />EXTEND HOUSEWRAP <br />AP <br />(7/8' NOM) OVER GALV MTL LATH <br />OVER NAILING <br />NAILING FLANGE <br />>, OVER 15# FELT OVER APPROVED <br />HOUSEWRAP <br />WD SHEATHING <br />(RE: STRUCT) <br />I <br />FASTEN TO WD STRUCTURAL <br />I� <br />s- MEMBER at 7" O.C. MAX <br />MTL DRIP FLASHING W/ <br />7/8" TO %" MID -WALL <br />HEMMED EDGE SET IN CONT <br />WEEP SCREED <br />BEAD OF SEALANT <br />TRIM (RE: ELEVATION) <br />cal Q <br />-- <br />{ EXTEND 12" SELF -ADHERING <br />-- <br />—:: <br />MEMBRANE FLASHING OVER <br />WINDOW FLANGE SET IN CONT <br />6" WIDE STRIP SELF ADHESIVE <br />BEAD OF SEALANT <br />_! <br />FLASHING, CLEAN MASONRY <br />- -. <br />BEFORE APPLYING <br />-- - -. <br />I VINYL FLANGE CASING BEAD <br />1/2" (MIN) STUCCO FINISH <br />INSTALLED PER MFR <br />WRITTEN SPECS (TYP) <br />TEXTURED PER COMMUNITY <br />SPECIFCATIONS <br />1 1/2" (MIN) STUCCO FINISH <br />TEXTURED PER COMMUNITY <br />SPECIFCATIONS <br />STUCCO <br />SIDING <br />HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) <br />DOOR HEAD at CMU <br />{ CMU LINTEL <br />(RE: STRUCTURAL) <br />CONTINUOUS BEAD <br />OF SEALANT <br />SELF ADHESIVE -OR- <br />FLUID APPLIED <br />FLASHING (CLEAN <br />gqM��AppS��OyyNNRGY�BEFORE <br />I DOOR FRAME <br />EXTERIOR <br />SCALE: 1 y2" = 1'-0" <br />SCALE: N.T.S <br />CMU WALL W/ <br />1/2" (MIN) STUCCO FINISH <br />(RE: STRUCTURAL) <br />GYP BRD OVER <br />tZ <br />1x2 TREATED <br />FURRING STRIPS _ __ <br />at CMU WALL (TYP) CONTINUOUS BEAD <br />Li <br />OF SEALANT <br />PT 1 x4 <br />PT 2x4 FRAME SELF ADHESIVE -OR- <br />FLUID APPLIED <br />ANCHOR FLASHING CLEAN <br />SHIM AS NEEDED gqMppAPPS��OyyNNRGYIBEFORE <br />METALI DOOR FRAME <br />INTERIOR EXTERIOR <br />DOOR JAMB at CMU <br />SCALE: 1 1/2" = 1'-0" <br />O <br />O <br />N <br />L <br />� <br />�- <br />O <br />N <br />O <br />AP <br />EX <br />4 <br />O <br />U <br />N <br />i <br />X <br />N <br />(V <br />M <br />J <br />LL <br />W <br />J <br />J <br />tds <br />� <br />Z <br />O <br />true design studios <br />U) <br />V <br />U <br />9000 REGENCY SQUARE BLVD. <br />o <br />SUITE 100, JACKSONVILLE, FL 32211 <br />O <br />r- <br />uj <br />O <br />W <br />H <br />Zs <br />� <br />Q <br />041HOMN' <br />a) <br />-I <br />m��,i <br />s <br />F <br />CL <br />U <br />Z <br />W <br />>� <br />W <br />O <br />O <br />O <br />O <br />LO <br />r- <br />Z <br />2E <br />w <br />Q <br />O <br />Of <br />0 <br />LL <br />W <br />U-1 <br />O <br />� <br />LL <br />�w <br />W <br />O <br />O <br />U <br />ti <br />X <br />= <br />Q <br />Z <br />a' O <br />0 <br />Q ~ <br />Z <br />U � <br />Z ILL <br />(D W <br />O -- Q <br />J U <br />O U) <br />Z <br />PROJECT NO W <br />U � <br />W Q <br />~ -- -- - Z <br />IX DRAWN (Da DVO U) <br />Q CHKD. w <br />Q TSD <br />O <br />m o <br />o <br />W U) <br />Z — <br />w <br />O J <br />Q <br />W U <br />C0 <br />Q U) <br />Z (D <br />Z <br />O � <br />_U <br />LL 0 <br />Q Z <br />REVISIONS: <br />0 No. Description Date o <br />O - - � - W <br />Z W <br />= W <br />U _ <br />w ~ <br />I— W <br />X Q <br />W cn <br />O <br />A501 O <br />0 <br />