Laserfiche WebLink
DocuSign Envelope ID: 49180716-722C-4488-8344-DC46395EF416 <br />TRUSS TO TOP PLATE, <br />MOISTURE BARRIER ---/ <br />UNO: <br />BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT <br />NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT <br />VERT. REINFORCING TO ---/ <br />W/ H2.5T OR RT7AT OR <br />HAVE 10" STANDARD <br />SDWC15600 <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y " IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />'PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1. COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/#5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />'/2' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2' WEDGE BOLT W/ MIN 4'/2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />■ EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYI <br />ROOF -TO-' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN'%32' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS. C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN I <br />FOR MISLOCATIO <br />INSTALL NEW MAc <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />-CORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />STEP DOWN TIE -BEAM <br />aw <br />• <br />O <br />� <br />O <br />IUD <br />PEX <br />0 <br />0 <br />N <br />U <br />CD <br />0� <br />Q. <br />i <br />CB <br />N <br />N <br />co <br />..,• <br />~� <br />J <br />LL <br />tdb <br />W <br />J <br />design studios <br />� <br />Z <br />O <br />U) <br />U <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />-7) <br />cn <br />0 <br />o <br />O <br />Lij <br />co <br />0 1"Hu"'190V <br />cF7 <br />or� <br />A � e` 4 at �7�•.I <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/y <br />31/4" <br />3746 <br />5„ <br />115/16 <br />33/4, <br />3 44"„ <br />6„ <br />2 %4" <br />3 3/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWSY4" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/s' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED <br />1x_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1x_ OR�6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, LINO) <br />W • <br />r <br />Q <br />W <br />U <br />Z <br />W <br />C7 <br />W <br />O <br />O <br />O <br />0) <br />LO <br />ti <br />a U) <br />Z LL]W 1..1..1 <br />Z J z Uj <br />v, O rW <br />co ULJ V / <br />co _ <br />w Q <br />w <br />W <br />z 0 <br />z p <br />w w <br />CJ LLjJ w <br />12� I..L <br />0 <br />LL LL <br />z a <br />z <br />O <br />Q <br />O <br />w <br />O <br />U <br />Q <br />0 <br />ABBOTT PARK <br />O <br />J <br />LOT 021-01 <br />Q <br />U <br />Z <br />} <br />OPROJECT NO: <br />JO 2021.006619 <br />DRAWN: <br />U KME <br />W CHKD: MJP <br />X <br />W <br />d <br />Q <br />Q <br />•'G�ENg* <br />4 .� <br />m •' �\ ' <br />0 W No 85166 <br />� r <br />Z <br />----Do*�Signed by: <br />• :� • � �TA"f�..OF <br />Ucj �0 3F4671DAC(kE .i4/% <br />FOR\° G�.`� <br />Z '.4fjs10NALE0%�. <br />Z) <br />O 05-18-2021 <br />i= <br />U REVISIONS: <br />LL <br />Q No. Description ! Date <br />U <br />0 <br />_J <br />O <br />Z <br />2 <br />U <br />W <br />H <br />X ST=5 <br />w <br />d <br />0 <br />W <br />ti <br />X <br />z <br />O <br />0 <br />w <br />I— <br />z <br />d <br />LL <br />w <br />J <br />Q <br />U <br />W <br />0 <br />w <br />I— <br />Z <br />U_ <br />W <br />w <br />0 <br />LL <br />O <br />0 <br />0 <br />L0 <br />W <br />J <br />a <br />U <br />U) <br />z <br />Q <br />Z <br />Q <br />0 <br />w <br />w <br />w <br />J <br />a <br />W <br />O <br />z <br />O <br />0 <br />CMU/METAL CONNECTOR ENGINEERING <br />