9 )ocuSign Envelope ID: A5CAA780-OD5C-4257-894E-716A13ODFF24 <br />EXISTING EXTERIOR CMU - <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO .. <br />EXISTING FOUNDATION FACE W/ n n D - - - - - n , <br />(2) ROWS OF Nfi' DIA. TAPCONS D / _- D D <br />OR CUT NAILS @ 24" O.C. COVER D n <br />FLUSH w/ 3000psi CONCRETE. <br />I i D EXISTING FOUNDATION. <br />D ° <br />nl D <br />I \ <br />D \ n <br />� A - <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL -1 <br />TO BOTTOM OF WINDOW SILL I <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO - <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. I <br />D EXISTING FOUNDATION <br />- I \ <br />• D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />t�� 0'-0" A.F.F. SEE ARCH <br />ti - - a -�- - - (MAX 20„ <br />Q ° a ° a ° DEEP) <br />-4 - - <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />_ - T <br />16" UNDER 2 STORY WALL <br />(6:4PEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />4 - 4 - - <br />/\�/i�\/\° <br />16" <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />L-- <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />'r4P #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />40.5 BAR BEND 90 DEGREE <br />fOP OF FOOTING <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWAL <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 22 <br />INTO MONOLITHIC THICKENED EDGE <br />LOCATE VERTICAL AND TIE INTO STEMWALL F <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />NO LITHIC SLAB <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4OR#5 <br />REINFORCING PER <br />MONOLITHIC FOOTING <br />SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />OOTING <br />CONCRETE SLAB W/ - <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />LU <br />O <br />VAPOR BARRIER �� j\\// <br />� <br />LO <br />Q <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />4 OR <br />FOOTING TO BEAR ON FIRM //�\\\' \\ #b IN BIONALRICK LE GE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT - 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1 AxW1.4 U J (1) #4 OR #5 <br />WWF OR FIBERMESH > e '` Q ¢ w CONT <br />I- <br />-° cwn ° <br />-,, FINISH <br />�. O GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM \ / <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO - 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />TSTEVWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />VARIES PER <br />36" MAX <br />ARCH PLANS <br />12" MIN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3 %" CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />VAPOR BARRIER <br />/ FOOTING TO BEAR ON FIRM <br />a' • / UNDISTURBED SOIL <br />b <br />1f' UNDER 1 STORY WALL VV%(( <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ <br />I#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36 MAX DEPTH <br />"NOTE•: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") U <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />_ STONE CLADDING FINISH - MIN 6" a, <br />ALL OTHER EXTERIOR WALL `" Q <br />N <br />CLADDING - MIN 8", U.N.O. ON ARCH r U <br />A �t <br />VAPOR BARRIER -%\� \\/�\/\/\/\/\/\/\ Z <br />O <br />\/\ ° 12" MIN/\/\\/\\/\\/\\ A PEX <br />LU <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK (n <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN <br />SOIL m ? <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 W <br />BAR IN BRICK LEDGE W <br />16" UNDER 2 STORY WALL w/ z 1✓ <br />(2) #5 OR (3) #4 CONTINUOUS <br />z <br />w tds -6 <br />MONOLITHIC FOOTING SECTION Q true design studios <br />1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE 0 <br />FOLLOWING OCCUR: w <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" O <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY J 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY � SUITE 100, JACKSONVILLE, FL 32211 <br />PERkS-0" HORIZONTALLWO PREVENT EROSION OF SOIL. z 904.821.5200 p <br />CONCRETE SLAB w/ 6x6 3 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR < cn <br />FIBERMESH O <br />-e a - o 041HOMON' <br />Q t <br />VAPOR BARRIER O <br />16" J <br />LL <br />Q <br />3 BEARING WALL FOOTING SECTION U <br />z <br />c� <br />CONCRETE SLAB W/ 6x6 0 <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH <br />0'-0" A.F.F. Z <br />SEE ARCH 7- <br />4 U <br />- DETAILS <br />\\\� 4 \ Uj <br />4 -�- H <br />8" MIN W <br />/. <br />Q cn <br />8"x8" THICKENED 8" X LU w <br />FTG AT <br />STEP-DOWN, SEE VAPOR BARRIER Q - <br />PLAN m <br />CURB STEP SECTION w = z w <br />4 - z O cn <br />a - <br />8" UNDER MASONRY WALL O <br />I W <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL z O <br />6x6 W1.4 x W1.4 WWF f Z > Q <br />OR FIBERMESH VARIES e � w <br />SEE ARCH U)W (MAX 16") I <br />- - ° O w Uj a <br />00 <br />�/\//\\//\\//\\//\\/\\\ u- <br />/\/a Q VAPOR BARRIER \//\� <br />U) X <br />6" OPT. EXTENSION IN BRICK } <br />LOCATIONS ON FND PLAN U► � <br />12" UNDER 1 STORY WALL w/ 0 O <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 Q 0 <br />BAR IN BRICK LEDGE z W <br />16" UNDER 2 STORY WALL w/ U <br />(2) #5 OR (3) #4 CONTINUOUS z <br />LU <br />Abbott Park a <br />5 GARAGE EXT WALL CURB SECTION x <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE W U_ <br />FOLLOWING OCCUR: Q LOT 020-01 W <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" - -- J <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY V <br />G7 <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. 0 <br />W <br />CONCRETE SLAB W/ 6x6 PROJECT NO: F- <br />W1.4 x W1.4 WWF OR Q <br />FIBERMESH 2021.003464 z <br />0'0' 0" A. F.F. -- - . - 0 <br />- ---- , SEE ARCH DRAWN <br />-� I (MAX 20° LDG w <br />a e 1 -� ° - DEEP) <br />CHKD: <br />4" MJP <br />4" EXTENSION <br />UNDER BRICK VENEER LO <br />12" UNDER 1 STORY WALL VAPOR BARRIER ��SiiN LA&1" -,, w <br />w/ (2) #4 OR (2) #5 CONT �••��G E N SF•.4 <br />16" UNDER 2 STORY WALL <br />w/ (3) #4 OR (2) #5 CONT ee%gned b1c U) <br />-- - \ / • * U) <br />BEARING CURB STEP SECTION f` <br />S71 TE OF <br />�F4A. <br />�i TYPICAL REINFORCING S/ONArc ` <br />BARS AT THICKENED ###I ll ►" U) <br />FOOTING, SEE PLAN 0 <br />03-18-2021 z <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH REVISIONS: <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS p <br />--- No. Description Date W <br />�L--_ - -- - - W <br />2 <br />HOUSE SLAB - J <br />- Q <br />RE-ENTRANT CORNER DETAIL W <br />(RECOMMENDED) 0 <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS wRT=2 D <br />■ Q <br />CMUUIMFTAI CONNFCTOR ENGINEERING <br />