My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7915 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7915 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:46:15 PM
Creation date
2/27/2025 1:13:27 PM
Metadata
Fields
Template:
Building Plans
Street #
7915
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2102
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: 54C2A7F5-648B-4BDD-AB94-3AF9820141D7 <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDC <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVE[ <br />FLUSH wl 3000psi CONCRETE. <br />.......... - <br />.......... <br />EXISTING FOUNDATION. <br />................. . .... <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />....... . ........ . I'll \-I 11 <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO X <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF'//16" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />71 ............ . <br />[> <br />EXISTING FOUNDATION <br />8" CMU WALL OVERHANGS 2.5" OR LESS, <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR, <br />CONCRETE SLAB W/ 6x6 <br />WIA x W1.4 WWF OR <br />FIBERMESH <br />Y-O"A.F.F. <br />. ........ .......Q.. ....... ............ SEE ARCH <br />. . . . .. ..... ........ ... (MAX 20" <br />DEEP) <br />4" <br />-- - - - ----- --------- <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />BEARING CURB STEP SECTION <br />........ . . - <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />- ---------- -- <br />4 <br />16" 1 VAPOR BARRIER <br />*EARJING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />L <br />........ . ....... <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMU STEMWALL MONO LITHIC SLAB <br />W-- -------- - <br />8" CMU CHAIR BLOCK W/ (1) #5 -_ CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />\ MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />I � y 6X6 W1.4 x WIA WWF <br />- ...... . ......... ........ OR FIBER MESH <br />• <br />V) - — — — — — — <br />LL1 Z <br />U) 0 <br />#4 OR #5 <br />REINFORCING PER <br />0 <br />L) Z <br />< <br />MONOLITHIC FOOTING <br />->SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />MIN112" <br />/xx'\>;/X, ,Xx <br />STEMILL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />....... .... .... ......... U) <br />....... ------ - UJ <br />U) <br />< 7- U) <br />C) <br />0 <br />VAPOR BARRIER Uj LOU <br />LL, <br />U) <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. 4 <br />4 TO 5 COURSES: 48" O.C. <br />X <br />N <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM #5 IN BRICK LEDGE <br />UNDISTURBED SOIL 4" OPT BRICK LEDGE <br />VERTICAL REINFORCEMENT NOTED ON FND PLAN <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS -- ------- ---- 1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />�/2 �, STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST. RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A. F. F. <br />---------------- <br />(BEYOND) <br />FLOATING CONCRETE U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 ¢ U U) (1) #4 OR #5 <br />=� WWF OR FIBERMESH > <br />wCONT <br />1JJ <br />w <br />LU U) <br />GRADE <br />Jy <br />=0 <br />FINISH <br />77 <br />X <br />x j� <br />X x/. <br />, <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR <br />UNDISTURBED SOIL #5 IN BRICK LEDGE <br />\ • <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />() STEMWALL CURB SECTION <br />7.......... . . .......... ............ <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT.- <br />VARIES PER <br />36" MAXI I(ARCH PLANS <br />12 MIN <br />XXX <br />N <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />ADDITIONAL NO. 4 OR NO. 5 <br />BAR IN BRICK LEDGE <br />1 <br />IkTAIIINILTILK,villitz' <br />31/2" CONCRETE SLAB W/ 6x6 <br />W1.4 x WIA WWF OR FIBERMESH <br />(1) #4 OR #5 90- BEND @ 48" O.C. <br />'j <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />. .............. <br />b <br />.01WER 1 STORY WALL N (2) <br />#4 OR (2) #5 CONT <br />16" UNDER 2 STORY WALL W/ (3) <br />:#4 OR (2) #5 CONT <br />I - - .. ......... ........ ... - _ <br />MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "IA" FTG DETAIL FOR THE "'I" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") <br />W1.4 x W1.4 WWF OR <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />> <br />STONE CLADDING FINISH - MIN 6" a, 0 <br />................... <br />1?f\I ALL OTHER EXTERIOR WALL > <br />C:) <br />x/' C:) <br />CLADDING - MIN 8", U.N.O. ON ARCH <br />\/X/ . ........ 1.\. N 0 <br />APEX <br />0U?INVAPOR BARRER�y <br />X\ (14 Q <br />00 <br />C:) a) <br />%/ . Tj % CF) Q. <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN <br />SOIL CN <br />12" UNDER 1 STORY WALL w/ m <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL wl Ld <br />(2) #5 OR (3) #4 CONTINUOUS _j tds i-i <br />true design studios <br />MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE 0 <br />FOLLOWING OCCUR. Cn <br />Y 9000 REGENCY SQUARE BLVD. <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 0 <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY < SUITE 100, JACKSONVILLE, FL 32211 C� <br />0 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALL'yTO PREVENT EROSION OF SOIL. 0 <br />C:) <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS — W1.4 x W1.4 WWF OR LIJ CY <br />FIBERMESH <br />HoRsH01ON' <br />x <br />WKW <br />bag <br />w <br />16" VAPOR BARRIER < <br />0Z) <br />W <br />3 BEARING WALL FOOTING SECTION U � <br />LLI <br />(D <br />w <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR 0 <br />FIBERMESH 0 <br />0'-0" A.F.F.0 <br />SEE ARCH <br />\4 DETAILS <br />LO <br />8" MIN <br />0 <br />z <br />Uj Uj <br />8"x8" THICKENED U) U) <br />FTG AT VAPOR BARRIER w <br />STEP-DOWN, SEE z LL <br />PLAN U) z w <br />0 CURB STEP, SECTION m W <br />w C) <br />UNDER MASONRY WALL z <br />Im <br />> 0 <br />CONCRETE SLAB W/ UNDER WOOD WALL z w C) < <br />ILLI <br />6x6 W1.4 x W1.4 WWF 0LLj <br />OR FIBERMESH VARIES SEE ARCH < J W <br />(MAX 16") Uj w <br />o <br />x <br />ILL. <br />12" MIN <br />X X X z <br />z <br />0 <br />0 VAPOR BARRIER <br />< 0 <br />ILIJ <br />6" OPT. EXTENSION IN BRICK 0 <br />LOCATIONS ON FND PLAN CL z <br />..... ....... � w <br />w/ 12" UNDER 1 STORY WALL 0 <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 C) <br />BAR IN BRICK LEDGE < <br />16" UNDER 2 STORY WALL w/ w <br />,(2) #5 OR (3) #4 CONTINUOUS Abbott Park <br />0 <br />GARAGE EXT WALL CURB SECTION <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF .- T1 1. . E U_ LOT 011-03 0 <br />FOLLOWING OCCUR: < . .......... ... ..... -------------- - ........... w <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U <br />< <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY z z <br />FROM STRUCTURE STEEPER THAN I'-0" VERTICALLY (D <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />Q <br />0 PROJECT NO: w <br />0 <br />CONCRETE SLAB W/ 6x6 1 2021.003507 <br />0 WFIBERMESH z 0 <br />DRAWN: <br />W1.4 x W1.4 WWF OR 0'-0" A. F. F. SEE ARCH 1: LDG 8_01 <br />0 <br />(MAX 20" w ----- - U-) <br />DEEP) CHKD <br />x MJP <br />w <br />4" w a- <br />4" EXTENSION x 0 <br />UNDER BRICK VENEER CO <br />;N LA'* <br />.. . . .......... -... i 4'- �0 ... U <br />12" UNDER I STORY WALLf*'.- �9 <br />E Nq 1. z <br />co �y <br />VAPOR BARRIER <br />w/ (2) #4 OR (2) #5 CONT <br />N 851 <br />16" UNDER 2 STORY WALL w z OCAIgn" < <br />w/ (3) #4 OR (2) #5 CONT z <br />------ ---- 1 --------- - ... . ...... .. <br />0 <br />0 Z <br />�6BEARING CURB STEP SECTION .0.�. 0 <br />ILLI <br />< <br />E F 4 35.. <br />z <br />z '�',J*f IrimAk <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />U) <br />0 03-26-2021 <br />w <br />REVISIONS: w <br />r <br />7- <br />No. Description Date I <br />- -- - --- - - ---------- - -- - -------- - - -------- ------- - ------------------------ <br />_j <br />0 <br />0 <br />F_ <br />- ----------------- --- --- - ....... . .. - ----------- .... ......... 0 <br />0 <br />z <br />. ....... .. . ................. ...... . ........ ............. ........... ........... <br />0 <br />0 <br />w <br />F_ <br />ST=2mtl <br />rMIUMPTAi rnmmr:rTr)R <br />
The URL can be used to link to this page
Your browser does not support the video tag.