Laserfiche WebLink
)ocuSign Envelope ID: 54C2A7F5-648B-4BDD-AB94-3AF9820141D7 <br />/.j <br />TRUSS TO TOP PLATE, MOISTURE BARRIER <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO -� <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32"O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />C <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k" IN TRUSS <br />(NOTE. IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1. COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SIP OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />W THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O C. <br />OR <br />W WEDGE BOLT W/ MIN 4'/z" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />j� <br />BOTTOM PLATE ANCHOR NOTES <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />� v <br />77, <br />\/j\, /V\ \\j\� �. <br />/ \ �/X <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />ROOF-] <br />COW <br />U <br />O <br />r <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />o <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATION "<X<1Y2_ <br />— — <br />— <br />— — — <br />3/4" BETWEEN TOP OF WOOD PANEL <br />FASTEN 2x6 NO. 2 SYP SHIM <br />—#5 CONT. <br />AND CENTER OF FASTENERS. <br />TO TRUSS W/ MIN (10) 10d <br />(1) #5 BAR CONT. <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />FOR MISLOCATION 112" <X <br />I <br />HEEL TRUSSES INSTALLED WITH LONG <br />INSTALL NEW MASONRY TWIST <br />DIMENSION PERPENDICULAR TO TRUSS END <br />STRAP TO INSIDE FACE <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 >2" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4" OR 11/4" <br />PER MANUF. <br />3" <br />5" <br />11/y <br />3 <br />115/16 <br />3 3/4 , <br />3 3/„ <br />6„ <br />2 J4' 3 3/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS 'W DIA. @ 30" O C. STAGGERED <br />• (2) ROWS Y/,f" DIA. @ 24" O.0 STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />l <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED '/") <br />1x_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />- 8" CMU WALL <br />TYPICAL DO <br />O <br />O <br />Lo <br />APEX <br />r <br />N <br />00 <br />r1' <br />O <br />Cf) <br />r <br />N <br />N <br />M <br />J <br />U- <br />W <br />tds <br />J <br />5; true design studios <br />O <br />Y 9000 REGENCY SQUARE BLVD. <br />Q SUITE 100, JACKSONVILLE, FL 32211 <br />3 <br />• <br />w <br />Q <br />0 <br />CO <br />U <br />z <br />W <br />W <br />w <br />O <br />O <br />O <br />0)t-L <br />ti ♦ ^ <br />0 V ) <br />z w <br />C w -- <br />w w <br />-� z w <br />m Uj o rr� <br />Of <br />W <br />z <br />OR/WINDOW JAMB TO BLOCK <br />z > C� Q <br />0 <br />OPENINGS, UNO) ¢ W w w <br />� w w <br />O xJ x <br />LL � LL r- <br />Z <br />0 z0 <br />d <br />� w <br />d z <br />o a <br />U W <br />p w <br />Abbott Park Q <br />o U <br />_j <br />LI LOT 011-03 0 <br />............... _ _ w <br />U Q <br />Z_ z <br />0 <br />U w <br />O PROJECT NO: W <br />2021.003507 <br />ILL <br />z _ .... _ _ ............. 0 <br />.......... <br />DRAWN: <br />U LDG o <br />W_._.._.__...._....._._......-_ ......................._...._..--._.......-... <br />F. CHKD. <br />MJP x <br />w w <br />U <br />4 ���►r��i�����i U) <br />>- `,�����5-SIN Lq/��'�•,�i C� <br />m �J�� �•E ni 54' 00 <br />0 • •. ?.� <br />LU <br />„* • N`bocubigneYdkt- : q� <br />Zr <br />o r -O r <br />w w 0 <br />z '�. /Ii��1QbEF435..z <br />A�%% Q <br />0 03-26-2021 0 <br />1= w <br />co <br />v REVISIONS: _ <br />QFNo. H <br />� Description Date w <br />V) J <br />o I- <br />J........._---__..........................._....._........-.._.._. o <br />oi Z <br />z................... I . .............. __ _ _.......... o <br />U <br />w <br />x <br />W ST=5 <br />Q <br />(`MII/MFTA►I roNNFrTnP FNf;INFFRINf, <br />