My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7937 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7937 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:45:43 PM
Creation date
2/27/2025 1:13:53 PM
Metadata
Fields
Template:
Building Plans
Street #
7937
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2103
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3ocuSign Envelope ID 1B419230-6309-4ABE-A8FF-31740391864F <br />EXISTING EXTERIOR CMU <br />Ij <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO j <br />EXISTING FOUNDATION FACE w/ ° p <br />(2) ROWS OF 316" DIA. TAPCONS / D D ° <br />OR CUT NAILS @ 24" O.C. COVER D ° <br />FLUSH w/ 3000psi CONCRETE. P 1> <br />D D EXISTING FOUNDATION. <br />D ° <br />D \ <br />I ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR r' <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL - <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO ° <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/16" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D EXISTING FOUNDATION <br />D ° <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECEN T CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0' _0" A.F.F. SEE ARCH <br />(MAX 20" <br />a ° d DEEP) <br />4„ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />"\\ <br />° ° / //\ <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />L <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMU STEMWALL MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />UJo- - - - - - - - -Lo° a°° ° <br />Of `d #4 OR #5 <br />z REINFORCING PER <br />MONOLITHIC FOOTING <br />v< SECTION <br />d <br />° FOOTING TO BEAR ON FIRM <br />° ° UNDISTURBED SOIL <br />MIN 112" <br />STEMWALL <br />MIN <br />OW MONOLITHIC FOOTING <br />12'E <br />*ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />A <br />8" CMU CHAIR <br />TOP OF SLAB h <br />I/BLOCK <br />W/ (1) #4 OR #5 CONT. <br />I <br />\\ \ \ \ <br />LLJ <br />VAPOR BARRIER /\ <br />Uj <br />X <br />< <br />IN <br />UP <br />PTO 3 COURSES:#5 VERT 72 0 ' CG \-'// <br />4 TO 5 COURSES: 48" O.C. <br />i // <br />\/� �. ° I/ <br />\\/ /\\ \\� ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� / ' #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT - 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE -- w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 Q v J (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q CONT <br />f- w <br />FINISH <br />/ / / O GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. j <br />4 TO 5 COURSES: 48" O.C. <br />L_D <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 �EAURB SECTION <br />SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />3 '/2' CONCRETE SLAB W/ 6x6 <br />(1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />36" MAX VARIES PER <br />ARCH PLANS <br />12" MIN <br />\ //\/// <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />V b <br />-VAPOR BARRIER <br />- FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />112" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO. 4 OR NO. 5 1#4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />1#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE : IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a, 0 <br />ALL OTHER EXTERIOR WALL <br />CLADDING - MIN 8". U.N.O. ON ARCH O 0 <br />���/��� � APEX 0 <br />VAPOR BARRIER `//��`Ai�V/���V\AAA/��,�VA�� .� <br />1\ M\ /\ j\ � C7 <br />FOOTING TO BEAR ON \/ <br />FIRM UNDISTURBED 6' OPT. EXTENSION IN BRICK <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE U_ <br />16" UNDER 2 STORY WALL w/ w <br />(2) #5 OR (3) #4 CONTINUOUS J td S J-6 <br />� <br />true design studios <br />CkF <br />NOLITHIC FOOTING SECTION z <br />NTACTFOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />LLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. O <br />O :3 <br />CONCRETE SLAB w/ 6x6 � <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W <br />FIBERMESH ? cn <br />° d <br />° <br />d d <br />\ VA411f meke W <br />... <br />16" VAPOR BARRIER Q � <br />0 <br />U <br />3 BEARING WALL FOOTING SECTION Z <br />w <br />(D <br />W <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />SEE ARCH <br />- g DETAILS ~ <br />� <br />//X // \ <br />>= <br />° 6 <br />8" MIN <br />o U) <br />Z <br />8"x8" THICKENED 8" U) <br />FTG AT w n/ <br />STEP-DOWN, SEE VAPOR BARRIER W L...11.... <br />PLAN U Z W <br />C4. CURB STEP SECTION m LU O U) <br />w <br />W Q <br />w Q O <br />8" UNDER MASONRY WALL Z <br />L Wz Q <br />6" UNDER WOOD WALL Q <br />CONCRETE SLAB WI � _ _ _ <br />6x6 W1.4 x W1.4 WWF W Uj LU <br />OR FIBERMESH VARIES ° SEE ARCH Q Q 2 <br />(MAX 16") W WOf <br />V'12/�./\\ LL L <br />VAPOR BARRIER /-//�;//ice/ O <br />-�v Q o <br />LU <br />6" OPT. EXTENSION IN BRICK 0 <br />1 LOCATIONS ON FND PLAN m Z <br />O <br />NDER 1 STORY WALL w/ <br />O OR (2) #4 CONTINUOUS `-- ADDITIONAL NO. 4 OR NO. 5 U W <br />BAR IN BRICK LEDGE - <br />NDER 2 STORY WALL w/ Q w <br />OR (3) #4 CONTINUOUS Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION - I U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 009-03 <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. U) <br />O PROJECT NO. w <br />CONCRETE SLAB W/ 6x6 J 2021.003503 0 <br />W1.4 x W1.4 WWF OR O W <br />FIBERMESH Z DRAWN O <br />F.F. SEE ARCH = LDG o <br />- U O <br />�-d - -- ; -- - -- - (MAX 20" W <br />LO <br />DEEP) � CHKO: <br />x MJP <br />\�\ x\/, d° a J <br />4" EXTENSION X <br />UNDER BRICK VENEER Q ,,���ttlififlllI <br />12" UNDER 1 STORY WALL �%�`` �J�' G•E N `�9 ���� <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m ` .•� `S�`••.• �� Z <br />16" UNDER 2 STORY WALL NO 85166 <br />DocuSlgrlet�,b <br />w/ (3) #4 OR (2) #5 CONT Z * \ y� <br />0 <br />6 BEARING CURB STEP SECTION •, 3 ` y s° ��'�: U) <br />Z <br />zI� E F435... <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />` <br />Cn IIIlffliiilit��� <br />O_ 03-23-2021 p <br />H W <br />U REVISIONS: LIJ <br />U_ ♦- <br />No. Description Date W <br />(n J <br />O H <br />Z Z <br />= O <br />U � <br />w <br />x <br />W ST=2mD <br />IZ <br />Q <br />rMII/MFTAI rr)K1kI;: `Tf1R PKIMMIZIMIAI(. <br />
The URL can be used to link to this page
Your browser does not support the video tag.