My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7937 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7937 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:45:43 PM
Creation date
2/27/2025 1:13:53 PM
Metadata
Fields
Template:
Building Plans
Street #
7937
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2103
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JocuSlgn Envelope ID. 1B419230-6309-4ABE-A8FF-317403918B4F <br />TRUSS TO TOP PLATE, MOISTURE BARRIER—/ <br />UNO: <br />BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT <br />NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT <br />VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR <br />HAVE 10" STANDARD <br />SDWC15600 <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k " IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />L--PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />'/2" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2" WEDGE BOLT W/ MIN 4'/2" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />7 °� <br />X//j /// <br />BOTTOM PLATE ANCHOR NOTES <br />EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />8" PARTIALLY GROUTED <br />- EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />- OR ST-2A (IF APPLICABLE) <br />a <br />Q <br />I I <br />PROVIDE DOWELS TO MATCH <br />o <br />VERTICAL WALL <br />Z <br />I I <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />° <br />°777/777�7/77x/\xx, <br />X\lnn \� x/x <br />\\%�Xj��/A <br />/xx fix//��/v fix/Vx/�x/ <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />TYF <br />ROOF -TO' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 12" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF ( RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN ( <br />FOR MISLOCATIOI <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />FCORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCIAIG <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />(1)#E <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />U <br />0 <br />N <br />0 <br />N <br />DIST FROM DOOR JAMB <br />MIN. SCREW <br />DIST FROM DOOR JAMB <br />MIN. SCREW <br />! WINDOW TO BLOCK <br />LENGTH <br />WINDOW TO BLOCK <br />LENGTH <br />3/4" OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/2 <br />31/4 " <br />3 7/16 <br />5„ <br />115/ fi <br />33/" <br />3 3/4, <br />6„ <br />2 %4" 3 3/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH, <br />• (2) ROWS%" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %6" DIA. @ 24" O C. STAGGERED <br />OR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED <br />1x_ PT NAILER <br />BUILT UP 2x_ ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DO <br />(TYPICAL FOR ALL MASO <br />0 <br />LJ <br />o <br />o <br />? <br />LF <br />O <br />N <br />APEX <br />N <br />0 <br />U <br />�t <br />CD <br />(ll <br />� <br />C2 <br />N <br />co <br />� <br />J <br />U_ <br />tds <br />W <br />J <br />a) <br />true de -sign studios <br />Z <br />O <br />U <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />71 <br />0 <br />o <br />o <br />W <br />H <br />U) <br />0 <br />041HOUION" <br />°> <br />ft a �a <br />CO f a 'j, z a �1, \ -0 <br />NRY OPENINGS, UNO) <br />W 5 <br />Df <br />Q .- <br />U <br />z <br />W <br />W <br />cK <br />0 <br />0 <br />CD <br />d') <br />rl- <br />>= <br />LO Cn <br />ti <br />o Q Z <br />U)W <br />-� z w <br />LLJ _O u� <br />m <br />� Q <br />w <br />w <br />z <br />OR/WINDOW JAMB TO BLOCK w i m o <br />o � J LLJ W W <br />O X <br />�' <br />J <br />z T <br />z Z <br />O O <br />a 0 <br />� w <br />a z <br />O a <br />U LL <br />Q W <br />� J <br />Abbott Park Q <br />O U <br />J (n <br />LL LOT 009-03 0 <br />Q w <br />U Q <br />z_ z <br />CD <br />CO <br />PROJECT NO W <br />O 0 <br />O 2021.003503 w <br />DRAWN: O <br />LDG <br />U 0 <br />0 <br />I.-CHKD MJP U) <br />x U) <br />w w <br />U <br />Q,►►►►►►i „ U) <br />�M LA <br />No 85166 .•••' <br />w = * ' DocuSigneq b_ Q <br />Z <br />i <br />.•' '. < p '••�44/� <br />F �••' z_ <br />z ,6EF435... <br />cn ����„ n ►►►►►►� Q <br />O 03-23-2021 p <br />w <br />U REVISIONS: <br />LL r <br />Q No. Description Date W <br />cn Q <br />0- - w <br />O F- <br />O zz <br />U <br />w <br />x <br />w ST=5 <br />w <br />(`MII/MFTAi rnNNFrTnR FN(;INFFRINr, <br />
The URL can be used to link to this page
Your browser does not support the video tag.