My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7948 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7948 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:24:11 PM
Creation date
2/27/2025 1:14:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7948
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: 357216A3-D625-4246-Al2A-59447DB9C38A <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO d d <br />EXISTING FOUNDATION FACE w/ - - - - <br />(2) ROWS OF 3/s' DIA. TAPCONSd D d D D <br />OR CUT NAILS @ 24" O.C. COVER D d <br />FLUSH w/ 3000psi CONCRETE. <br />D EXISTING FOUNDATION. <br />d <br />I D \ \ d <br />�� <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED 1 <br />MIN. 3" EDGE DISTANCE <br />I <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. i <br />1j D D EXISTING FOUNDATION <br />I° <br />D \ d <br />l � - <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />a <br />0'-0" A.F.F. SEE ARCH <br />-d - - °- - - - - <br />(MAX 20" <br />DEEP) <br />- d <br />O d <br />//\\ Q <br />d <br />/ <br />4" <br />a d <br />/ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL <br />VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*BEARING CURB STEP SECTION <br />16" <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />a <br />VAPOR BARRIER <br />*-DEARING WALL FOOTING SECTION <br />" ^ "` -1-- "SUS BAR AS <br />AP AS SHOWN <br />:..VIV I IIVUVUJ VVIV \J l�L I L <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWALL MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 2 <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />)DEGREE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />---- <br />- <br />-- °----g-°- <br />in- <br />- - - - - <br />- - - <br />, <br />�zp <br />a< < <br /><� °a d•4 ° <br />#4 OR #5 <br />=O <br />, , ° ° <br />REINFORCING PER <br />U Q <br />d ° <br />MONOLITHIC FOOTING <br />d <br />SECTION <br />°e • • <br />FOOTING TO BEAR ON FIRM <br />d L ° d° <br />UNDISTURBED SOIL <br />a 1 d° <br />MIN 112" <br />° <br />d < <br />d <br />//\//\//\//\//\//\//\// //\//\//\// ' ^ <br />�- • STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />•ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB <br />BLOCK W/ (1) #4 OR #5 CONT. <br />- <br />w <br />Q O <br />VAPOR BARRIER ��j\ <br />Q <br />� <br />oto <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM \\/ <br />\\ \\ \ ADDITIONAL #4 OR <br />//� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT <br />4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, <br />PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS <br />CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Ah <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1 AxW1.4 Q U U) (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q U) CONT <br />UJ <br />, ---• •> > e a, � FINISH <br />O GRADE <br />/\\%\\ <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. D o <br />i � I <br />_D <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM 4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />36" MAX VARIES PER <br />ARCH PLANS <br />12" NMN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3 %2' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM �2/,--(1) #4 OR #5 90° BEND @ 48" O.C. <br />\\\\\\; <br />c d d <br />d VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />b <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ <br />I#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36 MAX DEPTH <br />'NOTE`: IT IS ACCEPTABLE TO SUBSTITUTE THIS 1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />E <br />O <br />AM,\ <br />\ \ \ \ \ \ ALL OTHER EXTERIOR WALL <br />\ \ \ \ \ \ e D CLADDING - MIN 8", U.N.O. ON ARCH O O <br />VAPOR BARRIER \%\\ D \ \\///\///\\//\\//\\//\\/\\/� `- APEX <br />-� <br />12 ' M I N \/\/\/\/\/\� cV V <br />O N <br />FOOTING TO BEAR ON 6 OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M 400Zz. <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE LIL <br />16" UNDER 2 STORY WALL w/ LLI <br />(2) #5 OR (3) #4 CONTINUOUS J <br />tds J 6 <br />true design studios N <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211cn <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Q <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O <br />4- <br />CONCRETE SLAB w/ 6x6 N <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W a <br />FIBERMESH ~ <br />4 . . . DIMEN a) <br />\/ \ \ d <br />/\ J <br />Q a / m <br />16" VAPOR BARRIER Q <br />() <br />3 BEARING WALL FOOTING SECTION U CD <br />z <br />W <br />(D <br />W <br />CONCRETE SLAB W/ 6x6 0� <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />� -- <br />SEE ARCH <br />d- <br />a \ _ DETAILS <br />�\4 - - fl- <br />r ^ <br />8" MIN O V J <br />8"x8" THICKENED 8" Uj <br />U W <br />FTG AT W n/ <br />STEP-DOWN, SEE VAPOR BARRIER z 1I...W�` <br />PLAN <br />4 CURB STEP SECTION m Uj O 0 <br />- - W <br />LU <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ I--�--I 6"UNDER WOOD WALL__ Z Q Q <br />6x6 W1.4 x W1.4 WWF I I W W <br />OR FIBERMESH VARIES ° SEE ARCH 0 Q W <br />- --_� <br />- - - d ° - 4-8 - - (MAX 16") W <br />O X <br />\/\/\ c <br />\\/�\\���/\// / \ �/ �\\ W �, <br />\/\ d % 12" MIN\\/\\/\\/\\/\� Z � <br />>\\\/�/,\\j\\//\\//\\\ 0 <br />VAPOR BARRIER �// a a /�, /i\ / <br />6" OPT. EXTENSION IN BRICK <br />LOCATIONS ON FND PLAN 0- z <br />12" UNDER 1 STORY WALL w/ <br />O (2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 U <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL w/ Q W <br />(2) #5 OR (3) #4 CONTINUOUS J <br />Abbott Park Q <br />5 GARAGE EXT WALL CURB_ SECTION <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 013-01 0 <br />FOLLOWING OCCUR: H <br />LLI <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY iD <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (A <br />O PROJECT NO: W <br />CONCRETE SLAB W/ 6x6 -1 2021.003458 <br />W1.4 x W1.4 WWF OR O ILL <br />FIBERMESH Z DRAWN: 0 <br />0'-0" A.F.F. SEE ARCH U LDG o <br />-e - - - - (MAX 20" <br />d DEEP) CtiKD: <br />° X MJP U) <br />O d <br />x\ W W <br />a • ° J <br />U4" EXTENSION X <br />UNDER BRICK VENEER ��``����N t LA. <br />f����i U) <br />12" UNDER 1 STORY WALL �- ��%`` ��G E N <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : .• �,� Sk1% z <br />No <br />16" UNDER 2 STORY WALL W <br />w/ (3) #4 OR (2) #5 CONT Z> = = tY <br />BEARING CURB STEP SECTION <br />O �: ill <br />_. -- W GESTATE OF <br />6 ,• C3�4�6�76 B.A'*01'F4 Z.. <br />Z <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />i I I <br />TYPICAL REINFORCING <br />BARS AT ENED <br />FOOTING, SEE KPLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />- - - - - - <br />---_-_---------- <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />SEE NOTES (MAX 16") U <br />0 <br />STUCCO OR DIRECTLY ADHERED vi <br />STONE CLADDING FINISH - MIN 6" Q, <br />O <br />N <br />'fffff111t11��`,, <br />_O 03-22-2021 p <br />H W <br />co <br />_U REVISIONS: LU <br />U- m <br />Q No. Description Date W <br />U J <br />//Q <br />U) <br />O �-- <br />O Z <br />z O <br />= o <br />U <br />W <br />x W STm2mD <br />a <br />Q <br />CMUNFTAI CONNECTOR FNGINFFRING <br />m� <br />
The URL can be used to link to this page
Your browser does not support the video tag.