My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7961 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7961 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:24:54 PM
Creation date
2/27/2025 1:14:35 PM
Metadata
Fields
Template:
Building Plans
Street #
7961
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1926
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID. 38716031-B749-4FD2-9507-FCC2C574C8F1 <br />EXISTING EXTERIOR CMU <br />I <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ ° p Is _ — — — — —A. — D <br />(2) ROWS OF 3/6" DIA. TAPCONS / D D D ° D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D D EXISTING FOUNDATION. <br />D ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ — — — — — —& — ° <br />(2) ROWS OF 3/6" DIA. TAPCONS D / D D ° D D <br />_ OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. 1> <br />D EXISTING FOUNDATION <br />D ° <br />° D <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />— — (MAX 20" <br />° DEEP) <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*EARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />a a <br />° T d <br />VAPOR BARRIER <br />*KARIING WALL FOOTING SECTION <br />AM "` " SUS BAR AS <br />_AP AS SHOWN <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MONO LITHIC SLAB <br />MIN 24" LAP <br />DEGREE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />wo <br />a �a ,ad <br />a ° <br />#4OR#5 <br />0 i-n <br />a < <br />REINFORCING PER <br />< <br />MONOLITHIC FOOTING <br />° <br />SECTION <br />X V <br />a <br />• <br />FOOTING TO BEAR ON FIRM <br />d° <br />UNDISTURBED SOIL <br />MINI 12" <br />44 <br />/\/\ ' <br />/\\//\\/��\�\\ <br />`—• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE VERTICAL <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB a BLOCK W/ (1) #4 OR #5 CONT. <br />W <br />VAPOR BARRIER j\\ j ui o LO <br />#4 OR #5 VERT REINFORCING j <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />Li o <br />FOOTING TO BEAR ON FIRM\\ /\\\ \\%� ADDITIONAL #4 OR <br />UNDISTURBED SOIL <br />// / #5 IN BRICK LEDGE <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w_ <br />SLAB W/ 6x6 W1.4xW1.4 of <br />WWF OR FIBERMESH > <br />U-BLOCK W/ <br />J <br />(1)#4OR#5 <br />W <br />CONT <br />w U) <br />o � <br />FINISH <br />_ O <br />GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />L <br />I <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />3'/2" CONCRETE SLAB W/ 6x6 - <br />(1) #4 OR #5 CONT. <br />W1.4 x W1.4 WWF ORi FIBERMESH <br />MINIM <br />24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />36" MAX <br />VARIES PER <br />— — — °— —° fl — <br />—° <br />ARCH PLANS <br />///\//\X// <br />12" MIN <br />X`VAPOR <br />BARRIER <br />/\ <br />// //� <br />// // <br />d • <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION <br />b <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL W/I(2) <br />ADDITIONAL NO.4 OR NO. 5 <br />#4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ I(3 <br />I#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />''NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS S. <br />FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") U <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" > E <br />ALL OTHER EXTERIOR WALL `v O <br />\\ \\ \\ \\ \\ \\ ° p o CLADDING -MIN 8", U.N.O. ON ARCH O <br />VAPOR BARRIERPEX <br />\ 12" MIN/ <br />/\/\/\/\ /\� N c y <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ cN d <br />�� <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J 4_BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS W J <br />J N <br />> tru�e design studios <br />1 MONOLITHIC FOOTING SECTION_ z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: U) <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY O <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W������ <br />FIBERMESH <br />041HOMON' <br />---- — - --a --- — <br />/ 4\VAPOR <br />o \ o\ouj <br />.0111 <br />16" BARRIER Q <br />0 <br />BEARING WALL FOOTING SECTION U <br />z <br />w <br />(D <br />w <br />CONCRETE SLAB W/ 6x6 0� <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />�- _ SEE ARCH <br />a \d DETAILS L <br />\,\\ 8" M I N <br />O Q C) <br />Z LLI <br />8"x8" THICKENED g" U w <br />FTG AT W n/ <br />STEP-DOWN, SEE VAPOR BARRIER � � � 1L..��L <br />PLAN <br />4 CURB STEP SECTION m LLJ O C/) <br />W <br />w Q <br />8" UNDER MASONRY WALL _Z <br />6" UNDER WOOD WALL > Q Q <br />CONCRETE SLAB W/ Z W 6x6 W1.4 x W1.4 WWF _ w 0 <br />OR FIBERMESHIVARIES <br />WSEEARCH �2 <br />ate° (MAX 16") <br />LL <br />12" M I N �\\� Z <br />//\ a �/ �\\�/\\//\\\\//\\\ p z <br />VAPOR BARRIER a/�\\\� <br />� O <br />Q <br />\ / 6" OPT. EXTENSION IN BRICK 0 W <br />d <br />z LOCATIONS ON FND PLAN <br />12" UNDER 1 STORY WALL w/ O a <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U ILL <br />BAR IN BRICK LEDGE — <br />16" UNDER 2 STORY WALL w/ Q <br />(2) #5 OR (3) #4 CONTINUOUS W <br />Abbott Park <br />of Q <br />5 U) <br />GARAGE EXT WALL CURB SECTION <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 006-03 w <br />FOLLOWING OCCUR: <br />. OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" Cj Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY (D <br />PER T-0" HORIZONTALL)TO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: L I <br />CONCRETE SLAB W/ 6x6 O 2021.003500 <br />W1.4 x WI A WWF OR Q li <br />FIBERMESH z DRAWN: O <br />0'-0" A.F.F. SEE ARCH U LDG o <br />--d o (MAX 20" W LO <br />\\ \\ \\ a ° DEEP) x CHKD: MJP cf) <br />° •d W J <br />4" EXTENSION a <br />U <br />UNDER BRICK VENEER W <br />�iN Lq''�i <br />12" UNDER 1 STORY WALL�J5 NSF '��� <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m `� •,••��C' E N SF'9 ��� Z <br />o <br />16" UNDER 2 STORY WALL W * ' • :• <br />Q <br />W/ (3) #4 OR (2) #5 CONT Z <br />6 BEARING CURB STEP SECTION w '••, " TAT\E OF ..�� <br />Q � S� •3y6,�Ct F435...Z <br />z �'�S/CNALE��`� <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />�I RE-ENTRANT CORNERS <br />I i <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />O_ 03-23-2021 p <br />W <br />U REVISIONS: <br />L <br />Q No. Description Date <br />W <br />U <br />O ~O <br />O z <br />= o <br />U <br />w <br />I- <br />x <br />W ST=2,D <br />w <br />CMUIMETAL CONNECTOR ENGINEERING <br />IF <br />
The URL can be used to link to this page
Your browser does not support the video tag.