Laserfiche WebLink
)ocuSign Envelope ID: 38716031-B749-4FD2-9507-FCC2C574C8F1 <br />Is <br />TRUSS TO TOP PLATE, MOISTURE BARRIER <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --- <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y2" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/#5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 Fil <br />2x_ NO. SPF OR BETTER @ MAX 16" O.0 <br />BOTTOM PLT ANCHOR Q <br />THREADED ROD ANCHOR W/ MIN 4" -' <br />EMBED W/ NUT & WASHER IN SIMPSON o <br />co <br />ACRYLIC -TIE OR EQUIVALENT z_ <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2" WEDGE BOLT W/ MIN 4'/" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />< a. <br />< <br />77777 <br />• < • \\�\/\ \ \ I \\/ <br />xx <br />BOTTOM PLATE ANCHOR NOTES \\ • • 41 \\� <br />- EACH SILL PLATE SHALL HAVE A MIN. \ \ <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />/ <br />TYf <br />ROOF -TO' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 Y2" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />FOR MISLOCATION <br />FASTEN 2x6 NO. 2 S <br />TO TRUSS W/ MIN (1 <br />FOR MISLOCATION <br />INSTALL NEW MAS( <br />STRAP TO INSIDE F <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />FCORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />D <br />13 <br />U <br />0 <br />N <br />N <br />N <br />TEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB MIN. SCREW DIST. FROM DOORJAMB MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH / WINDOW TO BLOCK LENGTH <br />%4" OR 11/4" <br />PER MANUF. <br />3" <br />5" <br />11/2' <br />3 �4 , <br />3 7/16 <br />5„ <br />11;,1 6 <br />3 3/4 , <br />3 3/ , <br />61, <br />2 %4" <br />3 3/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS ''/;' DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %s' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED '/4") <br />1x_ PT NAILER <br />BUILT UP 2x ATTACHED TO MASONRY, (1) PLY <br />1x_OR�6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORAMNDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />O <br />N <br />LO <br />r <br />N <br />00 <br />d' <br />O <br />O-) <br />N <br />N <br />c'7 <br />J <br />LL <br />W <br />J <br />J <br />z <br />O <br />0 <br />U <br />Q <br />0 <br />CD <br />T_ <br />W <br />F__ <br />U) <br />J <br />m <br />w <br />0 <br />W <br />z <br />W <br />(D <br />W <br />O <br />O <br />O <br />m <br />ti <br />d' <br />z <br />co <br />cn <br />W <br />z <br />m <br />W <br />W <br />z <br />z <br />W <br />O <br />LL <br />z <br />O <br />i= <br />¢ <br />Oa <br />O <br />U <br />¢ <br />O <br />.J <br />LL <br />U <br />z <br />} <br />C� <br />O <br />.J <br />O <br />z <br />_ <br />U <br />w <br />x <br />w <br />W <br />X <br />m <br />0 <br />z <br />0 <br />w <br />Q <br />z <br />co <br />O <br />H <br />F— <br />U <br />LL <br />0 <br />C7 <br />O <br />J <br />O <br />z <br />_ <br />U <br />W <br />F— <br />X <br />w <br />0- <br />tdb <br />true design studios <br />� <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />Am <br />cn <br />VKHONN' <br />"� <br />\01 <br />o, a <br />N <br />c <br />W <br />¢ <br />0 <br />'t' <br />J <br />LLI <br />® <br />WW <br />W <br />X <br />X <br />LL <br />z <br />O <br />0 <br />w <br />I- <br />z <br />w <br />W <br />LL <br />w <br />Abbott Park -� <br />¢ <br />U <br />LOT 006-03 0 <br />w <br />z <br />(D <br />W <br />PROJECT NO: W <br />2021.003500 cl <br />LL <br />O <br />DRAWN: o <br />LDG <br />0 <br />CHKD: L0 <br />MJP <br />w <br />J <br />¢ <br />U <br />, STATE OF <br />..35y 5:7C1b G 1=435.. z <br />¢ <br />03-23-2021 p <br />w <br />REVISIONS: w <br />2 <br />No. Description Date ~ <br />w <br />J <br />U <br />--- W <br />O <br />z <br />O <br />0 <br />ST=5 <br />CMUIMETAL CONNECTOR ENGINEERING <br />