My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7962 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7962 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:30:08 PM
Creation date
2/27/2025 1:14:43 PM
Metadata
Fields
Template:
Building Plans
Street #
7962
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1881
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: 6709EDC1-6676-4AA5-B704-214BFECE650F <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN, 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />F, <br />I ' ' <br />D ° D <br />D D EXISTING FOUNDATION. <br />D ° <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES - <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE, , <br />STRIP OF WWF FROM F.F.E. TO - <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ p ° D - p - - - o p <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D D EXISTING FOUNDATION <br />ID \ <br />l � � <br />• D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />° <br />- - - - - - (MAX 20" <br />a DEEP) <br />°- <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />--° a- - ° -- ° --- a <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWALLJ4MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />-< 1 <br />� O ° ° $ ° °° ° #4OR#5 <br />0 - ° REINFORCING PER <br />0 Q r 4 ° ° MONOLITHIC FOOTING <br />SECTION <br />° <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />'TEND MIN <br />IC FOOTING <br />CAL TO BE <br />ITION ZONE <br />LOCATE VERT16AL AND I IE IN 10 S I EMWALL FOOTING <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB h BLOCK W/ (1) #4 OR #5 CONT. <br />LU <br />Q =O <br />VAPOR BARRIER - //\\// LU Uj o x <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.\/\\ /\\/\\ <br />4 TO 5 COURSES: 48" 0.C.1�/� <br />/�� ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />ILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. rik <br />BE <br />(BEYOND) <br />FLOATING CONCRETE w <br />U-BLOCK W/ <br />SLAB W/ 6x6 W1 AxW1.4 Q <br />U (1) #4 OR #5 <br />WWF OR FIBERMESH > <br />Q Q u) CONT <br />oti <br />wW w <br />FINISH <br />O GRADE <br />#4 OR #5 VERT REINFORCING% <br />UP TO 3 COURSES: 72" O.C.\\//�\//� <br />/ <br />4 TO 5 COURSES: 48" O.C. p ° <br />° <br />o <br />° <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />- ADDITIONAL OR <br />E <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM <br />OPT BRICK LEDGE <br />N <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE <br />ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN <br />STEMWALL FOUNDATIONS. <br />OR #5 CONT. 3'/2' CONCRETE SLAB W/ 6x6 <br />(1) #4 W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />36" MAX VARIES PER <br />ARCH PLANS <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION b <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL W/ 2 <br />() <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE -- <br />16" UNDER 2 STORY WALL W/ (3) <br />�#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS., <br />HIS .,1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") 2 <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" Q, p <br />\ \ \ \ \ \ ALL OTHER EXTERIOR WALL O <br />\\ \\ \\ \ \ \\ ° o CLADDING - MIN 8", U.N.O. ON ARCH O O <br />/,.//, //, X;>/�// /// p <br />VAPOR BARRIER /� ° k 12" PEXMIN//AA//Aj���//AA/V� N U <br />00 <br />O q) <br />FOOTING TO BEAR ON <br />FIRM UNDISTURBED 6" OPT, EXTENSION IN BRICK �- <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ cN <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 J {, <br />BAR IN BRICK LEDGE U_ <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS W <br />J tds J-6 <br />� <br />true design studios <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 vi <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY O <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O <br />CONCRETE SLAB w/ 6x6 <br />W <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />� <br />FIBERMESH <br />11HOUION <br />--- -- ° Q <br />w <br />16" VAPOR BARRIER Q <br />0 <br />U Q <br />3 BEARING WALL FOOTING SECTION z <br />w <br />0 <br />w <br />CONCRETE SLAB W/ 6x6 ry <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />- - - 0' 0" A.F.F. O <br />SEE ARCH � <br />DETAILS>= <br />~ <br />ti <br />MIN 0 v J <br />Z Uj <br />8"x8" THICKENED 8" U) Q <br />FTG AT W I..i.� <br />STEP-DOWN, SEE VAPOR BARRIER � � � W <br />PLAN <br />j�/�', CURB STEP SECTION Z) ULI O CI) <br />- _ W <br />w <br />8" UNDER MASONRY WALL Z_ O <br />6" UNDER WOOD WALL Q <br />CONCRETE SLAB W/ Z Uj Q o - <br />-- <br />6x6 W1.4 x W1.4 WWF W _ W <br />OR FIBERMESH VARIES ° � SEE ARCH < <br />(MAX 16") E W <br />/�VV//��./V//V//V�/\/\ ILL <br />�- <br />a 12" MINAA Z <br />O Z <br />VAPOR BARRIER <br />>� Q 0 <br />\ / 6" OPT. EXTENSION IN BRICK 0 w <br />LOCATIONS ON FND PLAN a Z <br />12" UNDER 1 STORY WALL w/ 0 a <br />(2) #5 OR (2) #4 CONTINUOUS - ADDITIONAL NO. 4 OR NO. 5 U LL <br />BAR IN BRICK LEDGE <- <br />16" UNDER 2 STORY WALL w/ w <br />(2) #5 OR (3) #4 CONTINUOUS J <br />Abbott Park Q <br />_GARAGE EXT WALL CURB _j U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 011-01 0 <br />FOLLOWING OCCUR: w <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 0 Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (A <br />O PROJECT NO w <br />CONCRETE SLAB W/ 6x6 J 2021.003456 � <br />ILL <br />W1.4 x W1.4 WWF OR 0 0 <br />FIBERMESH Z DRAWN <br />A 0'-0" A.F.F. SEE ARCH = LDG o <br />- -- - ° (MAX 20" <br />O <br />a ° -� a DEEP) CHKD MJP <br />w w <br />4" EXTENSION x C) <br />UNDER BRICK VENEER Q -(�N Lq�,�U) <br />12" UNDER 1 STORY WALL N� <br />SF ' 0 <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m `� �,•�\G E N85166 <br />,3'- �Z <br />0 <br />16" UNDER 2 STORY WALL Z ` * N DocuSignidobl(: <br />w/ (3) #4 OR (2) #5 CONT J <br />0 ' � `ftAT '`' ' �. cn <br />6 BEARING CURB STEP SECTION w , <br />- - �(/ U, <br />P .• <br />z .,. 13P��7�p6 , ObEF435..- <br />U) `��1111111"tt� Q <br />TYPICAL REINFORCING <br />BARS AT THICKENED 0 03-19-2021 <br />FOOTING, SEE PLAN 1- w !!^ <br />V/ <br />MIN 24" LONG #4 OR #5 0 REVISIONS: w <br />BAR SET AT MID -DEPTH _ 2 <br />LL <br />OF SLAB, TYP ALL Q NO. Description Date ~ <br />RE-ENTRANT CORNERS W <br />L - <br />L-------- 0 -- - - ---- c) <br />--- - <br />------ --- OJ O <br />HOUSE SLAB 0 Z <br />Z 0 <br />RE-ENTRANT CORNER DETAIL w <br />w <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ALL W <br />ST=2mD <br />RE-ENTRANT CORNERS 0- <br />Q <br />rMIIIMFTAI rr)m i=rTIi1R FNIf;INIFFRINIf; <br />
The URL can be used to link to this page
Your browser does not support the video tag.