My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7962 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7962 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:30:08 PM
Creation date
2/27/2025 1:14:43 PM
Metadata
Fields
Template:
Building Plans
Street #
7962
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1881
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1_ I l__ _ <br />Doou5,9n Envelope 10. 6709EDC1-6676-4AA5-B704-214BFECE650F <br />TRUSS TO TOP PLATE, MOISTURE BARRIER <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />I <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y2" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/#5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />Y2" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />W WEDGE BOLT W/ MIN 4'/2" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />'EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />ROOF-7 <br />COW <br />U <br />0 <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />CD <br />EACH END, BLOCKING MAY BE OMITTED <br />N <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATION Y8 <X<1'r�" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />FASTEN 2x6 NO. 2 SYP SHIM <br />#5 CONT. <br />AND CENTER OF FASTENERS. <br />TO TRUSS W/ MIN (10) 10d <br />- <br />(1) #5 BAR CONT. <br />MIN 19/2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />FOR MISLOCATION 1k" <X <br />HEEL TRUSSES INSTALLED WITH LONG <br />INSTALL NEW MASONRY TWIST <br />DIMENSION PERPENDICULAR TO TRUSS END <br />STRAP TO INSIDE FACE <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />#5 CONT. <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />O <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />' ' O <br />APEX <br />N (} <br />0 <br />0 <br />d) p. <br />� N <br />N <br />N <br />co <br />_1 <br />LL � <br />W t S <br />J <br />J � <br />true design studios <br />Z <br />O <br />U 9000 REGENCY SQUARE BLVD. <br />Q SUITE 100, JACKSONVILLE, FL 32211 <br />co <br />o <br />O <br />W U. <br />H <br />U) <br />041HOMON' <br />co �0 <br />a <br />w <br />Q CL <br />U <br />Z <br />W <br />U <br />W <br />ry <br />O <br />O <br />O <br />>= <br />ti <br />O a U) <br />Z w <br />Cn 0. <br />W <br />J z w <br />LLJ O U) <br />m <br />� cl <br />W <br />W <br />Z_ <br />0 > Q Q <br />w ca w <br />Uj w <br />Df 0 W w <br />x <br />O <br />J <br />z a LL� <br />z <br />O z <br />F- O <br />Q 0 <br />0� w <br />CL z <br />w <br />O D_ <br />0 <br />0 LU <br />Abbott Park Q <br />O U <br />J U) <br />LL LOT 011-01 0 <br />Q w <br />z Z <br />O <br />PROJECT NO: W <br />O 2021.003456 0 <br />O LL <br />Z DRAWN: - — -- - — O <br />U LDG o <br />w CHKD L0 <br />MJP <br />x <br />w w <br />Q U <br />Q`1����rirrrr�,� to <br />�•E N*,3 q <br />00 ••�\ �•• 1 Z <br />' w No 85166 r Q <br />z = * DocuSigne*"b : < <br />;w. <br />•,• • �: <br />I z '�7���bEF435..§ <br />cn ��rr►rrr><>`��` Q <br />F O 03-19-2021 p <br />1= w <br />U REVISIONS: LU <br />Q No. Description Date w <br />w <br />U J <br />Q <br />} — -- U <br />C7 - U) <br />O I— <br />O OZ <br />} = O <br />U 0 <br />w <br />H <br />X <br />W ST=5 <br />W <br />CMU/METAL CONNECTOR ENGINEERING <br />co �0 <br />a <br />w <br />Q CL <br />U <br />Z <br />W <br />U <br />W <br />ry <br />O <br />O <br />O <br />>= <br />ti <br />O a U) <br />Z w <br />Cn 0. <br />W <br />J z w <br />LLJ O U) <br />m <br />� cl <br />W <br />W <br />Z_ <br />0 > Q Q <br />w ca w <br />Uj w <br />Df 0 W w <br />x <br />O <br />J <br />z a LL� <br />z <br />O z <br />F- O <br />Q 0 <br />0� w <br />CL z <br />w <br />O D_ <br />0 <br />0 LU <br />Abbott Park Q <br />O U <br />J U) <br />LL LOT 011-01 0 <br />Q w <br />z Z <br />O <br />PROJECT NO: W <br />O 2021.003456 0 <br />O LL <br />Z DRAWN: - — -- - — O <br />U LDG o <br />w CHKD L0 <br />MJP <br />x <br />w w <br />Q U <br />Q`1����rirrrr�,� to <br />�•E N*,3 q <br />00 ••�\ �•• 1 Z <br />' w No 85166 r Q <br />z = * DocuSigne*"b : < <br />;w. <br />•,• • �: <br />I z '�7���bEF435..§ <br />cn ��rr►rrr><>`��` Q <br />F O 03-19-2021 p <br />1= w <br />U REVISIONS: LU <br />Q No. Description Date w <br />w <br />U J <br />Q <br />} — -- U <br />C7 - U) <br />O I— <br />O OZ <br />} = O <br />U 0 <br />w <br />H <br />X <br />W ST=5 <br />W <br />CMU/METAL CONNECTOR ENGINEERING <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST- FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4" OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/2, <br />3%4" <br />37 6 <br />5„ <br />115/6 <br />33/" <br />33/" <br />6„ <br />2 j4, <br />33/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS 'W DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6" DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED ''/<") <br />lx_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOOR/WINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />
The URL can be used to link to this page
Your browser does not support the video tag.