My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7975 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7975 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:02:07 AM
Creation date
2/27/2025 1:14:52 PM
Metadata
Fields
Template:
Building Plans
Street #
7975
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1925
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: A8963624-09DD-415B-9F80-E752BDB957DB <br />i <br />I% <br />TRUSS TO TOP PLATE, <br />MOISTURE BARRIER----/ <br />UNO: <br />BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT <br />NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT <br />VERT. REINFORCING TO —/ <br />W/ H2.5T OR RT7AT OR <br />HAVE 10" STANDARD <br />SDWC15600 <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />C <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 12" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM WI #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x- NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />'/7' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W! NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />Yz' WEDGE BOLT W/ MIN 4%" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />-EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />° <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN. <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOVTHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYI <br />ROOF -TO-' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 7V32" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 1�" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W1 HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN ( <br />FOR MISLOCATIOI <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />FCORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (LINO). MINIMUM 48" LAP Wl MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4, ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />C? <br />0 <br />N <br />0 <br />N <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4" OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/2, <br />31/4 ' <br />3 7/I 6 <br />5„ <br />115/ d <br />3 3/4 , <br />3 3/4 " <br />6" <br />2 %4" 3 3/4 <br />IL <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH <br />• (2) ROWS t/4" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %E" DIA. @ 24" O.0 STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB. DO NOT EXCEED Y.") <br />1x_ PT NAILER <br />BUILT UP 2x_ ATTACHED TO MASONRY: (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />- 8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />U <br />O <br />O <br />CV <br />C3 <br />a <br />O <br />APEX <br />N <br />O <br />U <br />N <br />114. <br />O <br />O <br />t0 <br />Q <br />co <br />N <br />N <br />tM` <br />J <br />i2 <br />W <br />tds <br />J <br />J <br />true design studios <br />a) <br />O <br />U) <br />Y <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />N <br />O <br />o <br />O <br />r- <br />W <br />F_ <br />j <br />DoRsHOMON' <br />o <br />J <br />Q <br />AU44& <br />m <br />w .. <br />Q <br />U) <br />U <br />z <br />w <br />W <br />Cif <br />O <br />O <br />O <br />LO <br />r- <br />a <br />z w <br />W <br />Z J Z Uj <br />U)� rwn <br />v tb _ <br />LU <br />W QW <br />z_ `'� <br />3 /" <br />W w Q Q <br />t� 0 <br />o � j�� W <br />�' r.i+ I� <br />J X <br />LL. <br />LL <br />z a <br />z <br />O z <br />O <br />Q � <br />w <br />d z <br />O a <br />U U- <br />`L W <br />J <br />Abbott Park <br />O U <br />_I (n <br />U- LOT 005-03 <br />d w <br />F- <br />z Z <br />0 <br />0U)O PROJECT NO: LLJ <br />j 2021.003499 <br />w <br />DRAWN: <br />U LDG o <br />CHKD � <br />x MJP <br />w w <br />U <br />Q �t��t�Itll�itr�� U)� S�CiN Lq� ��i�� CO <br />lG•E•N S � Z <br />o D8cLt6igpeda%y 86 <br />w = Q <br />=' t t. 7t o <br />•,3 <br />ti, 13 STATE OF <br />i VJ <br />LL1 c .. O •• ,�c ' <tr� '^ <br />�sS.�``� <br />Q <br />p 03-26-2021 p <br />1=I W <br />U REVISIONS: <br />LL <br />No. Description tion Date <br />- - --- �- <br />----------- - -------------------------------....... <br />;w <br />Lo J <br />o- - - - F- <br />JU-------.-_L. - -..... O <br />Z..................!................ -.....-..................----------------.._......-i..... - .. z <br />= O <br />U 0 <br />w <br />I- <br />X <br />W ST=5 <br />CMU/METAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.