Laserfiche WebLink
,e <br />DocuSign Envelope ID: A8963624-09DD-415B-9F80-E752BDB957DB <br />O 0 <br />O <br />N <br />V- p <br />'OR <br />t PEX <br />0 <br />x <br />r 0 <br />r ii <br />N <br />N <br />M <br />,J <br />W <br />U, <br />J <br />J <br />Z tds <br />-Q <br />0 true design studios <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. <br />o SUITE 100, JACKSONVILLE, FL 32211 c <br />o ui <br />O <br />Wi <br />U) <br />RRHOMON' <br />/ \ ELECTRIC METER co <br />J <br />ELECTRIC METER FIELD VERIFY LOCATIONLIJ <br />a <br />FIELD VERIFY <br />PRE -FORMED CONTROL 'I \ LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) <br />JOINT W/ STRIP LATH 518" CEMENT PLASTER r LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC <br />- - -- <br />12" WIDE SELF-ADHESIVE METER <br />--------- FLASHING CENTERED UNDER - <br />4 � CONTROL JOINT (CLEAN CAVITY TO BE FILLED U <br />E - MASONRY BEFORE APPLYING) I WITH RIGID POLYMERIC W <br />f ISOCYANOTE-POLYBLEN U, <br />FOAM ("GREAT STUFF" OR W <br />- --- SIMILAR) <br />-- --..- - <br />V CD <br />APPLY A SILICON BASE <br />a <br />_ STUCCO FINISH I SEALANT AT POINT THAT C) <br />--------- - - - ----..._ 1 ELEC WIRE PENETRATES j <br />1 5/8"CEMENT PLASTER / <br />/ 6" SELF ADHESIVE <br />12" WIDE SELF-ADHESIVE OVER TOP & SIDES ti <br />FLASHING CENTERED UNDER i _ r--_--/_/I <br />CONTROL JOINT (CLEAN \ SELF FLASHING z <br />MASONRY BEFORE APPLYING) / UNIT - - <br />-� PROVIDE STUCCO U) <br />PRE -FORMED CONTROL <br />uJ <br />Sw <br />JOINT W/ STRIP LATH SCRATCH COAT LARGER <br />THE ELECTRIC <br />- - z W <br />M PREMANUR METER CAN OR METER — <br />\ DRYER VENT CAP <br />CAN COMBO OR METER n/ <br />! (SET IN CONT. AREA TO RECEIVE CAN AND DISCONNECT ca (.L <br />—!' SEALANT) STUCCO SCRATCH COAT W <br />8" CMU SEALANT at & 1 COAT OF PAINT W/ W <br />TOP & SIDES BACK -ROLL PRIOR TO W <br />------ - -- <br />Z <br />ELECTRIC METER <br />INSTALLATION Z C <br />w O <br />a <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION o 0 <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. � W <br />Z W <br />o LL <br />H Q <br />0 <br />LU <br />WOOD CONST BEYOND j FIBERCEMENT -OR- VINYL LAP d L <br />WOOD SHEATHING «a SIDING OVER APPROVED <br />+; HOUSEWRAP INSTALLED PER O r <br />6" SELF -ADHERING WEATHER RESISTIVE �'1 FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS X <br />FLASHING BARRIER #1 13..{ %— U <br />THREE COAT STUCCO FINISH Q r <br />EXTEND HOUSEWRAP <br />WEATHER RESISTIVE {" `i� ( NOM) OVER GALV MTL LATH OVER NAILING FLANGE r <br />r WEATHER RESISTIVE WD SHEATHING 0 <br />BARRIER #1 OVER 15# FELT OVER APPROVED _ Z <br />\ BARRIER #2 (RE: STRUCT) d d <br />VINYL ANGLED Q\ HOUSEWRAP WD SHEATHING <br />WEATHER RESISTIVE \ \ I' O <br />(� 10 Xj (RE: STRUCT] <br />CASING BEAD BARRIER #2 E� <br />{AM66-ANGLED-1250) _ \ 5/16" X 7 1/4" LAP TO WD STRUCT RAL tL t. FASTEN U W <br />\ SIDING W/ 6 REVEAL kt MEMBER at 7" O.C. MAX fF MTL DRIP FLASHING W/ cC Abbott Park z_ <br />' -- - <br />STARTER STRIP 'r " TO 4 " MID -WALL HEMMED EDGE SET IN CONT <br />2 1 ` s s BEAD OF SEALANT <br />WEEP SCREED � p., <br />CORNER BEAD �. �. / DO NOT CAULK OR I TRIM (RE: ELEVATION Z <br />8" CMU _ LOT 005-03 — <br />(FASTENER & 6" SELF -ADHERING <br />d.. �" C- SEAL OPENING <br />x� I!- <br />x - <br />o z SPACING at 7"O.C.) FLASHING J <br />- SELF -ADHERING <br />z o EXTEND 12" SELF AD <br />...., FLASHING OVER <br />m F N GALV'D METAL °• • d AL Z - TIN CONT d '� <br />I <br />GALV'D MET WINDOW FLANGE SE �1 <br />= w N "Z' FLASHING <br />Cr) .: FLASHING 6" WIDE STRIP SELF ADHESIVE <br />_ BEAD OF SEALANT {� <br />w w - / FLASHING, CLEAN MASONRY <br />�, <br />> I DO NOT CAULK OR f 1 1/4" X 6" SIMULATED BEFORE APPLYING VINYL FLANGE CASING BEAD = PROJECT NO 0 <br />UJ m_w i <br />Q - - SEAL OPENING -_ _ WOOD TRIM MEMBER _-_ - I INSTALLED PER MFR U W <br />{ WRITTEN SPECS (TYP) W 2021.003499 1/2" (MIN) STUCCO FINISH ~ <br />/ STUCCO TEXTURED PER COMMUNITY <br />_ CMU 1 1/4" X 6" SIMULATED 1/2" (MIN) STUCCO FINISH Z <br />. . <br />- .__-.- VINYL CASING WOOD TRIM MEMBER ;'� ` . CASING BEAD SPECIFCATIONS DRAWN LDG <br />d ' <br />TEXTURED PER COMMUNITY W _ <br />1/2" {MIN} STUCCO FINISH �'---------- <br />' SPECIFCATIONS fn <br />BEAD (AM66-1250) Q cHKr W <br />TEXTURED PER COMMUNITY SEAL GAP W! CAULKING — \t 0 <br />1/2" (MIN) TEXTURED SPECIFCATIONS X TSD <br />FINISH at MASONRY OR APPROVED SEALANT / , �+ (� Q <br />STUCCO CASING BEAD �i' STUCCO SIDING } o <br />LO <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) LU <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. w <br />SCALE: N.T.S. O Q <br />W U <br />Q U) <br />Z 0 <br />Z <br />C SELF ADHESIVE -OR- FLUID I- <br />1!2" (MIN) STUCCO APPLIED PAN FLASHING (CLEAN WISH ~ <br />CMU WALL W! � �, CMU WALL W/ <br />FINISH TEXTURED 4s" STUCCO FINISH ! , : _ MASONRY BEFORE APPLYING) CMU LINTEL 1/2" (MIN) STUCCO F U , <br />PER COMMUNITY y RE: STRUCTURAL) EXTEND UP AT JAMBS (4" MIN) 1z" GYP BIRD OVER ( E. STRUCTURAL) y�" GYP BIRD OVEP, { E. STRUCTURA) LL Ci3 26 2021 <br />PRE -SHAPED STUCCO BAND:. <br />PER <br />"�"GYP BRD OVER GYP BRD OVER - - <br />/ AL R L <br />1x2 TREATED - ND <br />�-- 1x2 TREATED <C <br />1x2 TREATED '' PRE SHAPED STUCCO B I � _ � =- -- A i � .. 1x2 TREATED , <br />W/ SLP TOP INSTALLED PER ( W/ INSTALLED PER MFR <br />- — <br />FURRING STRIPS -� MFR WRITTEN SPECS (RE: FURRING STRIPS - FURRING STRIPS CONTINUOUS BEAD MU WALLRiPS - CONTINUOUS BEAD WRITTEN SPECS (RE: ELEV} <br />' .r. ELEV at CMU WALL TYP '� � ' .. PRECAST CONCRETE SILL at CMU WALL (TYP) at C FURRING {TYP) F SEALANT <br />} REVISIONS: � <br />FLANGE CASING — at CMU WALL (TYP) ) (TYP) OF SEALANT O SEALA Q <br />SELF ADHESIVE -OR- FLUID 4! SELF ADHESIVE -OR-FLUID PT 1x4 ! Ci <br />BEAD WOOD BLOCKIN :.! 4 " BACKER ROD W/ SEALANT <br />y' APPLIED FLASHING (CLEAN APPLIED FLASHING (CLEAN ! s PT 1x4 SELF ADHESIVE -OR- SELF ADHESIVE -OR O NO. Description Date r� <br />=1� MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) i VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED <br />GYP BRD OVER j INSTALLED PER MFR PT 2x4 FRAME ANCHOR r! FLASHING (CLEAN ANCHOR FLASHING {CLEAN z r_ <br />PT 1x WOOD BUCK PT 1x WOOD BUCK _ <br />VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD 1x2 TREATED -- i WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE MASONRY BEFORE - W <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR gpp�ylN SHIM AS NEEDED - gppLYl <br />j WRITTEN SPECS (TYP) i WRITTEN SPECS (TYP) FURRING STRIPS CMU STEMWALL W! METAL D OR FRAME METAL WOR FRAME U -� <br />! at CMU WALL (TYP) 58' STUCCO FINISH W <br />W <br />I- <br />4 " BACKER ROD W/ SEALANT 4 " BACKER ROD W/ SEALANT INTERIOR EXTERIOR INTERIOR EXTERIOR I- - <br />s e (RE: STRUCTURAL) <br />1 - - Uj <br />3: <br />91 <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR W <br />U <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU _ Q <br />SCALE: N.T.S. SCALE: 11/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" z <br />A501 O <br />0 <br />