DocuSign Envelope ID: FF938094-F8E1-45F2-846F-29196AA35ECF <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ (2) ROWS OF 3/6" DIA. TAPCONS / <br />OR CUT NAILS @ 24" O.C. COVER D ° <br />FLUSH w/ 3000psi CONCRETE. <br />D EXISTING FOUNDATION. <br />D ° <br />° D <br />D \ <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE U <br />.I <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ I ° p ° D - -D D - - o p -� - ° ; <br />(2) ROWS OF 3/s' DIA. TAPCONS / <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D EXISTING FOUNDATION <br />D \ <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />jk 0'-0" A.F.F. SEE ARCH <br />-, - - e- - - - - (MAX 20" <br />° a ° ° DEEP) <br />\//\\/\\\/\\ ° ° <br />/ 4„ <br />a e <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />4 ° <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />' An =` ^^"'T'"" If-%UO BAR AS <br />AP AS SHOWN <br />LIWIYIIIYIJV VV VVIYVI\L I" <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMUIr <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />U)O <br />OU) <br />UZ <br />�(a) <br />) DEGREE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4 OR #5 <br />REINFORCING PER <br />MONOLITHIC FOOTING <br />SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />+ STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCA VERTICAL / AND TIE INTO STEMWALL FOOTING <br />REINF RCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />- - - - - - - w <br />(n <br />a Q o <br />VAPOR BARRIER /\\� I W wo X <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.\/\\ <br />4 TO 5 COURSES: 48" O.C.\�/�/ /\/ j�/// , <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM ADDI <br />\/ . //�\ \' #5 DI BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. lei <br />(BEYOND) <br />FLOATING CONCRETE w_ <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />U-BLOCK W/ <br />U U)(1)#4OR#5 <br />w LU LU <br />w CONT <br />- <br />(1) w <br />FINISH <br />/ O GRADE <br />\/\\/\\ \\ \ \ \\ \\\ <br />\\\\ a <br />l <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT: <br />36" MAX VARIES PER <br />___\ ARCH PLANS <br />12" MIN` <br />,. \ . <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3 %" CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM <br />24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />° <br />VAPOR BARRIER <br />/ <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />b <br />12" UNDER 1 STORY WALL W/ <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ <br />I#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1.1 <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />D <br />VAPOR BARRIER <br />o ° <br />Z) <br />SEE NOTES (MAX 16") U <br />0 <br />STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH -MIN 6" <br />N <br />ALL OTHER EXTERIOR WALL <br />CLADDING - MIN 8", U.N.O. ON ARCH O O <br />\%� APEX <br />�\ 12 M IN00 <br />c:) {D <br />FOOTING TO BEAR ON T. <br />6"OPEXTENSION IN BRICK <br />FIRM UNDISTURBED <br />SOIL LOCATIONS ON FND PLAN <br />N <br />12" UNDER 1 STORY WALL w/ <br />M <br />~` <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />J <br />f, <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/tds <br />LL <br />w <br />(2) #5 OR (3) #4 CONTINUOUS <br />J <br />z <br />true design studios <br />� <br />1 MONOLITHIC FOOTING SECTION <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />O <br />FOLLOWING OCCUR: <br />U) <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />U <br />9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211cb <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY <br />O <br />PER S-0" HORIZONTALLWO PREVENT EROSION OF SOIL, <br />O <br />O <br />w <br />CONCRETE SLAB w/ 6x6 <br />w <br />N <br />cy <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH <br />~ <br />cy <br />cn <br />01HURION <br />W <br />zzz <br />VAPOR BARRIER Q <br />n <br />0 <br />r <br />3 BEARING WALL FOOTING SECTION Z <br />w <br />0 <br />w <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR c:) <br />FIBERMESH O <br />0'-0" A.F.F. C) <br />SEE ARCH <br />\ DETAILS <br />LO <br />8" MIN O U) <br />\\, Z W <br />8"x8" THICKENED 8" <br />FTG AT U) <br />STEP-DOWN, SEE VAPOR BARRIER w <br />PLAN z z I..0 <br />40CURB STEP SECTION m W O Cn--- IY <br />w Q <br />w Q O <br />8" UNDER MASONRY WALL I Z <br />6" UNDER WOOD WALL Z Q Q <br />CONCRETE SLAB W/ i <br />6x6 W1.4 x W1.4 WWF w Uj W � <br />OR FIBERMESH VARIES�� ° SEE ARCH Q ILLI <br />Q ' , ' 2 <br />° -- (MAX 16") W - <br />LL <br />MIN %/\\//\\//\\//\\\� Z <br />/�/%�/\\/\\\ <br />VAPOR BARRIER �// ° a /i / O <br />6" OPT. EXTENSION IN BRICK 0 w <br />a LOCATIONS ON FND PLAN Z_ <br />12" UNDER 1 STORY WALL w/ 0 � <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 O IL <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL w/ �Q w <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park Q <br />5 GARAGE_EXT WALL CURB SECTION <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 003-03 W <br />FOLLOWING OCCUR: *OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />O PROJECT NO: w <br />CONCRETE SLAB W/ 6x6 1 2021.003493 U- �- <br />O <br />FIBERMESH Z DRAWN: O <br />W1.4 x W1.4 WWF OR <br />0'-0" A.F.F. SEE ARCH U LDG o <br />- -z­ - - - (MAX 20" <br />a ° DEEP) CHKD: <br />° a - Q4 X MJ P <br />4 w w <br />/ n- <br />\\\� 4" EXTENSION X U <br />UNDER BRICK VENEER L'A,�� w <br />12" UNDER 1 STORY WALL �' ��JJ�' G E N N/�'4'��i <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m i ; '�,� s�'•,• �� Z <br />16" UNDER 2 STORY WALL W = * NO 85166 •:: * Q <br />W/ (3) #4 OR (2) #5 CONT Z _ <br />6 BEARING CURB STEP SECTION STATE OF :�4U <br />-- - - T '•� , U' <br />z <br />i I I <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />I �I RE-ENTRANT CORNERS <br />L_ - - _ - - _ _ - - - - <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />U) '111111111110% Q <br />_O 03-23-2021 p <br />H 'W'^^ <br />VJ <br />U_ REVISIONS: _ <br />LL H <br />Q No. Description Date w <br />U) J <br />Q <br />U) <br />O <br />Z Z <br />= O <br />U 0 <br />w <br />I- <br />X <br />W ST=2mD <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />