Laserfiche WebLink
)ocuSign Envelope ID: FF938094-F8E1-45F2-846F-29196AA35ECF <br />t <br />TRUSS TO TOP PLATE, MOISTURE BARRIER <br />LINO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ HS OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />1 <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y " IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x— NO. SPF OR BETTER @ MAX 16" O.0 <br />%' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />%2' WEDGE BOLT W/ MIN 4'/z" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />//\ �\\` <br />BOTTOM PLATE ANCHO=NOTES <br />■ EACH SILL PLATE SHAOF (2) BOTTOM PLATE■ INSTALL ANCHORS WIEND OF SEGMENT (BU <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYF <br />ROOF -TO! <br />CONNE( <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN'%' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN I <br />FOR MISLOCATIO <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />a <br />J <br />in <br />N <br />Z <br />2 <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />#5 CONT. <br />CMU BOND BEAM <br />BOND BEAM REINFO FORCING <br />AT CORNERS <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x— NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/y <br />314" <br />37 6 <br />5„ <br />115/16 <br />3 3/ , <br />3 3/„ <br />6„ <br />2 %4, <br />33/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS Y<" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %6" DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED 'W) <br />1x_ PT NAILER <br />BUILT UP 2X_ATTACHED TO MASONRY, (1) PLY <br />1x_ OR 6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />~ <br />E <br />O <br />U <br />o <br />O <br />N <br />> <br />O <br />O <br />LO <br />N <br />C <br />APEX <br />s <br />U <br />N <br />O <br />O <br />N <br />N <br />N <br />co <br />�~ <br />J <br />ILL. <br />W <br />tds <br />L1 <br />J <br />J <br />true design studios <br />i-i <br />N <br />> <br />O <br />W <br />U <br />Q <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />co <br />o <br />O <br />cb <br />W <br />� <br />011HOMON' <br />c <br />cy' <br />cn <br />m <br />W�. <br />Q Q. <br />0 <br />W <br />� N <br />Z <br />W <br />0 <br />W <br />IY <br />O <br />O <br />O <br />O <br />LO <br />u7 <br />ti <br />o Q U) <br />Z w <br />W 0. <br />- z w <br />LIJ O U) <br />m <br />w <br />W Q <br />W <br />Z <br />w <br />z 0 Q <br />m <br />Q J w W <br />w w <br />O d• J X <br />LL LL <br />Z Z <br />O O <br />Q 0 <br />w w <br />F- <br />0- Z <br />0� w <br />O a <br />U U_ <br />p w <br />Abbott Park Q <br />O U <br />J (n <br />u' LOT 003-03 0 <br />Q w <br />U Q <br />Z_ Z <br />OPROJECT NO: w <br />J 2021.003493 0 <br />ILL. <br />Z DRAWN: O <br />0 LDG o <br />Iw" CHKD: � <br />X MJP U) <br />w w <br />Q U <br />Q�i������Itrr�i�i W <br />0 No 85166 •• <br />w <br />Q <br />Z �� < <br />O <br />STATE OF .' 44/ <br />w . O ••. w . <br />U) <br />iF•< p RI ,ZQ is <br />Z �11111111►1%j%`�0.1;s/ONAL' <br />U) <br />O 03-23-2021 0 <br />w <br />U_ REVISIONS: <br />W — I­_Q No. Description Date W <br />(n J <br />Q <br />O H <br />Z Z <br />= O <br />U 0 <br />LU <br />H ST=5 <br />w <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />A• <br />