Laserfiche WebLink
)ocuSign Envelope ID: 8912F9C8-E511-4OB6-8EAF-12FOECADCDD3 <br />} <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D ° <br />D <br />I D EXISTING FOUNDATION. <br />\ <br />D <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />— — — — (MAX 20" <br />d <br />DEEP) <br />a Q a <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL `— VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />a <br />16" <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />1 A Il JAG ^r%krr1h11 1`lU0 BAR AS <br />_AP AS SHOWN <br />L/VI\ 111\VVVV VVIYVI\L 1 L <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />DEGREE <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />LIJ <br />fn <br />Q o <br />VAPOR BARRIER ��\\� I w o LO <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM //� / ADDITIONAL #4 OR#5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. 1-6 <br />(BEYOND) <br />FLOATING CONCRETE w_ U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 U (1) #4 OR #5 <br />WWF OR FIBERMESH > Q ¢ CONT <br />>ti wW <br />U En <br />-- — a, ; • FINISH <br />0 GRADE <br />/, <br />#4 OR #5 VERT REINFORCING \\\\\\�\\%/\\�/ /\\/ <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />(f�TEMWALL CURB SECTION <br />. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL CMU STEMWALL MONO LITHIC SLAB 73'/2' CONCRETE SLAB W/ 6x6 <br />WHERE NEEDED 8" CMU CHAIR BLOCK W/ (1) #5 (1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH <br />CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP d a d <br />MIN. 3" EDGE DISTANCE I VARIES PER <br />36" MAX ARCH PLANS \ \ \ \ \ <br />4" CONCRETE SLAB W/ a a a /\ /\ <br />STRIP OF WWF FROM F.F.E. TO _ — — a - OR FIBER ME6x6 W1.4 x SH <br />TRIP \\ \/\\\\� <br />BOTTOM OF FTG. WWF TO �� //\//\//\ / \� <br />' VAPOR BARRIER <br />Wz------- —�— Qe <- �a----�--�—, \/\/\/ 12"MIN �. d e \ <br />\ \ \ \ FOOTING TO BEAR ON FIRM <br />EXISTING FOUNDATION FACE w/ ° p — — — — — — — D <br />#4 OR #5 UNDISTURBED SOIL <br />3 /\//\ //\/� / / <br />(2) ROWS OF /611 DIA. TAPCONS / \\�\ <br />OR CUT NAILS 24" O.C. COVER / D ° O co < . . REINFORCING PER <br />FLUSH w/ 3000psi CONCRETE. . e / \ <br />@ Q a , <br />d MONOLITHIC FOOTING '\ <br />d a SECTION 6" OPT. EXTENSION b <br />D EXISTING FOUNDATION Q ' IN BRICK LOCATIONS <br />• i °I I D D � -°e d �—e —<- a a e FOOTING TO BEAR ON FIRM ON FND PLAN <br />\\ e_ UNDISTURBED SOIL 12" UNDER 1 STORY WALL W/ (2) <br />ADDI da . MIN112" /\\/\\/\\/\\/\\/\\/\\ BAR I IN BRICK LEDGE <br />NO. 5 #4 OR (2) #5 CONT <br />�'\//\//\//\//\//\//\\ 16" UNDER 2 STORY WALL W/ (3) <br />D e #4 OR (2) #5 CONT <br />_ j\\ / <br />---= <--- <br />\\ \\ \\ \\ \\ \\ \\ /\//\//\//\//\//\//\// /\//\//\//\//\/,\ ,�\ 1 MONOLOTHIC FOOTING SECTION - 36" <br />MAX DEPTH <br />8�� CMU WALL OVERHANGS 2.5�� OR LESS STEMWALL /�\ \\�\\/ STEMWALL FOOTING TO EXTEND MIN <br />//\\ 12" BELOW MONOLITHIC FOOTING 'NOTE`': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />NOTES: \ \ \\/�\,� • ADDITIONAL #4 OR #5 VERTICAL TO BE <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, LOCATED WITHIN TRANSITION ZONE FTG DETAIL SPECIFIED ON THE FDN PLAN @ANY LOCATIONS THAT THE FTG <br />LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING DEPTH EXCEEDS 28". <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. TWO CHOICES: <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, 1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />CONTACT EOR. CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a) <br />CD E <br />ALL OTHER EXTERIOR WALL <br />\\ \\ O <br />\ \ \ \ o D CLADDING - MIN 8", U.N.O. ON ARCH <br />VAPOR BARRIER \%\\ ° p \\\\\\\\/\\/� O <br />�\ APES <br />/ 00 <br />(1) <br />O a)FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK 01 <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN m <br />SOIL �— <br />12" UNDER 1 STORY WALL w/ N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 co <br />BAR IN BRICK LEDGE <br />J 16" UNDER 2 STORY WALL w/ <br />LL <br />(2) #5 OR (3) #4 CONTINUOUS <br />W <br />J tds -6 <br />1 MONOLITHIC FOOTING SECTION j true design studies a <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z > <br />FOLLOWING OCCUR: O <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN 1'-O" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. 0 <br />O <br />CONCRETE SLAB w/ 6x6 O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR f <br />FIBERMESH W cy <br />~ CD <br />01,109ON" 'D <br />Q L <br />J <br />/ 16" VAPOR BARRIER w <br />zzz <br />Q � <br />cy <br />3 BEARING WALL FOOTING SECTION <br />z <br />w <br />CONCRETE SLAB W/ 6x6 0 <br />W1.4 x W1.4 WWF OR W <br />FIBERMESH w <br />0'-0" A.F.F. 0 <br />SEE ARCH 0 <br />DETAILS CF) <br />a <br />8" MIN <br />p <br />8"x8" THICKENED 8' ZFTG AT <br />w <br />STEP-DOWN, EE VAPOR BARRIER U) iiimm co /�/ <br />PLAN w w <br />CURB STEP SECTION ? Z W <br />4 000� <br />o cn <br />J _ <br />8" UNDER MASONRY WALL w <br />W <br />Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL <br />6x6 W1.4 x W1.4 WWF J�4 <br />z / <br />OR FIBERMESH VARIES SEE ARCH w W W Ly <br />(MAX 16) <br />— — — — — — d " <br />a <br />e � V w <br />w <br />/\/\ / / <br />�/\�// / /\ O x <br />12" MIN. \\�\\�\\�\\�\� LJLLL <br />X <br />VAPOR BARRIER \// a a /�. /i / O Z <br />H O <br />6" OPT. EXTENSION IN BRICK < 0 <br />LOCATIONS ON FND PLAN O w <br />12" UNDER 1 STORY WALL w/ CL Z <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 Ix <br />O d <br />BAR IN BRICK LEDGE U <br />16" UNDER 2 STORY WALL w/ LL <br />(2) #5 OR (3) #4 CONTINUOUS Q <br />� W <br />Abbott Park Q <br />5 GARAGE_EXT WALL CURB SECTION <br />O U <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE —1 (� <br />FOLLOWING OCCUR: Q LOT 008-01 0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U Q <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY Z Z <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. — 0 <br />} <br />CONCRETE SLAB W/ 6x6 0 PROJECT NO: w <br />W1.4 x W1.4 WWF OR 0 0 <br />FIBERMESH O 2021.003451 LL <br />0'-0" A.F.F. SEE ARCH Z DRAWN: O <br />--d — — — 20" <br />(MAX LDG <br />' a e d I DEEP) U cp <br />Q-4 o d 41: CHKD: MJP <br />X <br />W w <br />4" EXTENSION Q Q <br />UNDER BRICK VENEER X U <br />Q `�tttit�tttr��� cn <br />12" UNDER 1 STORY WALL NO <br />JN• LA&/ -' iO.- <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER <br />16" UNDER 2 STORY WALL 0 gg55 <br />w/ (3) #4 OR (2) #5 CONT W bti§Wned ' <br />- - — -- Z <br />CURB STEP SECTION 0 <br />*_B�RING �AF <br />w <br />— ---- - --- Z1� F43R.. <br />TYPICAL REINFORCING zONA� <br />BARS AT THICKENED QQ <br />FOOTING, SEE PLAN 0 04-10-2019 Q <br />MIN 24" LONG #4 OR #5 F- w <br />BAR SET AT MID -DEPTH I'- (1) <br />U OF SLAB, TYP ALL REVISIONS: w= <br />RE-ENTRANT CORNERS � <br />II Q No. Description Date W <br />L--— — — — — — — J <br />1------------- _ 0 <br />HOUSE SLAB 0 O <br />O Z <br />RE-ENTRANT CORNER DETAIL U 0 <br />(RECOMMENDED) w <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS W <br />ST=2D <br />11 <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />