Laserfiche WebLink
• <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />cli <br />16" 1 VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />--0'-0" A.F_F. <br />SUNDER 1ST( <br />16" UNDER 2 STORY WALL 11 <br />SEE ARCH <br />(MAX 20" <br />- DEEP) <br />j <br />IN, 4" EXTENSION <br />UNDER BRICK VENEER <br />6 BEARING CURB STEP SECTION <br />'OR BARRIER <br />CONCRETE SLAB W/ <br />64 W1.4 x WlA WWF <br />OR FIBER MESH <br />TOP OF SLAB h <br />VAPOR BARRIER - <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />w <br />_ U) <br />o: J O <br />wWU <br />un <br />UJ <br />UJ� Q <br />n <br />N. n L/ e --& <br />FOOTING TO BEAR ON FIRM /\�/. //�\\\' \\ #b W BIR CKLLEDGE <br />UNDISTURBED SOIL 4" OPT BRICK LEDGE <br />VERTICAL REINFORCEMENT -- NOTED ON FND PLAN <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS — <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALLPARTICULARLY WHEN IT IS OVER 4 , <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Ah_ <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 U (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q CONT <br />.ti ww w <br />---.--�---- � I � U) � • � FINISH <br />\//\\'\'\/, "x X /�\/ <br />\ <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. \//\\ <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO -- <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />-- FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />( CONCRETE SLAB W/ 6x6 <br />1) #4 OR #5 CONT. <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIMUM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />VARIES PER <br />36" MAX --- -- o— — -- -- �- v° --- - - <br />ARCH PLANS C <br />QI\//\\T/j12" MIN X.`'OR BARRIER <br />FOOTING BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO.4 OR NO. 5 (2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE - - <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />1 MONOLOTHIC FOOTING_SECTION - 36" MAX DEPTH <br />*NOTE`: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />' 9" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />U <br />0 <br />rn <br />� N <br />(MAX 16") O <br />A <br />PEX <br />u? <br />/V//V�/\/\/\ <br />VAPOR BARRIER /? ; k/, 12" MIN`/\� ��//\�/\\/\�000 <br />U <br />0 N <br />/\\ <br />/, <br />FOOTING TO BEAR ON ---- <br />FIRM UNDISTURBED 6" OPT, EXTENSION IN BRICK � <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J +, <br />BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL wl L <br />(2) #5 OR (3) #4 CONTINUOUS tds -6 <br />true design studios <br />MONOLITHIC FOOTIN_G_SEC_TION z <br />1 % CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />/ FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUIJD ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Q <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL, O <br />O <br />CONCRETE SLAB w/ 6x6 c <br />(2) #4 OR (2) #5 CONTINUOUS W1 4 x WlA WWF OR LU cy <br />cy <br />FIBERMESH <br />DoRsH019ON' <br />m <br />/t � 11 <br />16" VAPOR BARRIER Q <br />i� <br />U) <br />3 BEARING WALL FOOTING SECTION U <br />Z <br />ILL! <br />CD <br />LU <br />CONCRETE SLAB W/ 6x6 CK <br />W1 4 x W1.4 WWF OR <br />FIBERMESH O <br />0' 0" A.F.F. O <br />SEE ARCH � <br />DETAILS ti <br />�..... 8" MIN <br />O V ) <br />8"x8" THICKENED I 8" I CIO L Q <br />FTG AT-.---1 <br />STEP-DOWN, SEE VAPOR BARRIER LLI 1..` <br />PLAN U J Z W <br />\ /f LU o CURB STEP SECTION LUL.0 <br />Q <br />8" UNDER MASONRY WALL —I Z < O <br />CONCRETE SLAB W/ — —� 6" UNDER WOOD WALL - IZ M Q Q <br />6x6 W1.4 x WlA WWF W <br />OR FIBERMESI I I M LU <br />VARIES SEE ARCH 0 Q W 2 <br />-- <br />(MAX 16") <br />O <br />LL <br />12 MIN j AX \; <br />Z a <br />\iA ` <br />VAPOR BARRIER -- / <br />/ W <br />6" OPT. EXTENSION IN BRICK <br />_ LOCATIONS ON FND PLAN a Z_ <br />12" UNDER 1 STORY WALL w/ a <br />(2) #5 OR (2) #4 CONTINUOUS �— ADDITIONAL NO. 4 OR NO. 5 U LL <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ Q J <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park Q <br />- -� O U <br />GARAGE EXT WALL CURB SECTION <br />CONTACT FOR PRIOR 10 CONSTRUCTION IF ANY OF THE Q LOT 007-01-A 0 <br />\ _= FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" b <br />H <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ Z <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: LV <br />CONCRETE SLAB W/ 6x6 O 2020.001717 <br />W1.4 x W1.4 WWF OR O LL <br />FIBERMESH Z DRAWN: O <br />0'-0" A.F.F. SEE ARCH = SLC o <br />- ,- U o <br />- -- - - - - (MAX 20„ <br />a d d - ----- DEEP) CHKD. <br />��- -- W LU <br />4" EXTENSION <br />-�_ UNDER BRICK VENEER ,,,����N�LA;,;-,-,, <br />12" UNDER 1 STORY WALL %' �� JJ ��••��� • /� ,�� 0 <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m `�� . '� G, E N R ���� Z <br />-- o 51 •• <br />16" UNDER 2 STORY WALL LLl <br />w/ (3) #4 OR (2) #5 CONT Z <br />0 <br />BEARING CURB STEP SECTION 0�.,• ST E OF •:�w� (� <br />Al <br />�0 N A� <br />- TYPICAL REINFORCING <br />BARS AT THICKENED O 02/2512020 0 <br />FOOTING, SEE PLAN <br />E— LU <br />MIN 24" LONG #4 OR #5 ~ <br />\ BAR SET AT MID -DEPTH U REVISIONS: _ <br />< <br />OF SLAB, TYP ALL Q p No. Description Date ~ <br />I\ RE-ENTRANT CORNERS w <br />\� -- - --- -- --- cn -j <br />- -- - <br />- - -- - - -- - O --- <br />O <br />HOUSE SLAB O Z <br />Z O- - -- — -- - - _ _ <br />RE-ENTRANT CORNER DETAIL U <br />LU <br />(RECOMMENDED) (- <br />PLAN VIEW, DETAIL TYPICAL @ ALL W <br />ST=2,D <br />RE-ENTRANT CORNERS a- <br />(`Ml11MFTAI [:01KINIPCTOR FN[.INFFRINr. <br />