Laserfiche WebLink
DESIGN CRITERIA AND LOADS <br />Building Code <br />Florida Building and Residential Codes , <br />6th Edition (2017) <br />Code for Design Loads <br />ANSI/ASCE 7 <br />ROOF LOADING ............................................... <br />Cd = 1.25 <br />TOP CHORD LIVE LOAD..................................20 <br />PSF <br />TOP CHORD DEAD LOAD................................7 <br />PSF (TILE = 15 PSF) <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE ............... <br />20 PSF (PER FRC) <br />ATTICS WITHOUT STORAGE .......................10 <br />PSF <br />(NON -CONCURRENT) <br />BOTTOM CHORD DEAD LOAD.......... <br />5 PSF <br />WIND LOADING ................................................. <br />Cd 1.60 <br />ASCE 7-10, 3S GUST........................................139 <br />MPH <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY..................................0 <br />BUILDING CATEGORY.....................................II <br />ENCLOSURE CLASSIFICATION ...................... <br />ENCLOSED <br />INTERNAL PRESSURE COEFF.......................0 <br />18 <br />C&C DESIGN PRESSURES..............................(SEE <br />TABLE 1) <br />FLOOR LOADING..............................................Cd <br />= 1.00 <br />TOP CHORD LIVE LOAD..................................40 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD..........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING .... Cd = 1.00 <br />TOP CHORD LIVE LOAD.... .............................60 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD ...........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD ........................ <br />5 PSF <br />MAXIMUM FLOOR TRUSS SPACING...............16" <br />O.C. <br />DEFLECTION CRITERIA <br />LL / 240 <br />ROOF TRUSSES .............................................. <br />TL / 180 <br />TL MAX 1" UP TO 40' SPAN <br />LL / 480 <br />TL / 360 <br />OPEN WEB FLOOR TRUSSES ....................... <br />LL/480 <br />TL/240 <br />WOOD I JOISTS ............................................... <br />TL MAX ''/z„ <br />ILL / 360 <br />BEAMS1.............................................................TL <br />/ 240 <br />-NOTES: <br />1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL <br />ABOVE SHALL NOT EXCEED 34" DEFLECTION <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />ZONE DESIGNATION <br />IZ - Interior Zone (psf) <br />EZ - End Zone (psf) <br />0 - 20 ft2 <br />+28.54 -30.96 <br />+28.54 <br />-38.22 <br />21 - 50 ft2 <br />+27.17 -29.59 <br />+27.17 <br />-35.47 <br />51 - 100 ft2 <br />+25.52 -27.94 <br />+25.52 <br />-32.17 <br />101 - 200 ft2 <br />+24.25 -26.67 <br />+24.25 <br />-29.64 <br />VINYL SOFFIT MAX PRESSURE (psf) <br />+28.6 <br />-38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24.6 <br />END ZONE KEY MAP <br />END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1ST 4.0' PER FIGURE R301.2 (7) <br />1 ST FLOOR cNP> <br />-END ZONE <br />DESIGNATION <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />AUITCC 4 A <br />0 0 <br />STUCCO AND DIRECTLY <br />MIN'%32" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR ('/s' 24/16 <br />w = <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE <br />^ <br />Q w <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />w <br />LU <br />U J ? <br />ALL OTHER VENEER <br />MIN %6 " 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); <br />6" O.C. AT PANEL EDGES, 12" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />x C� <br />TILE ROOF <br />MIN'%32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />wz ;z-(NOTE <br />7) <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 4" O.C. AT PANEL EDGES AND <br />U_ = w <br />8" O.C. IN THE FIELD <br />F- I•- <br />Oz <br />SHINGLE AND METAL ROOF <br />MIN %6" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />0 = <br />O <br />(NOTE 9) <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 6" O.C. AT PANEL EDGES, 12" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />2%2" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O,C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN %" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN %2" EXTERIOR GYPSUM <br />CEILING BOARD. FASTEN w/ 5d x 1 " COOLER NAIL OR NO.6 x 1'/4" LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES: <br />1. FOR SHEATHING THICKNESS GREATER THAN 15/32" CATEGORY (32/16 SPAN RATING), USE 10d RING SHANK NAILS IN LIEU OF 8d RING <br />SHANK NAILS. (0.148" x 3" LONG). <br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS. <br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO HELP <br />REDUCE SQUEAKING, 8d RING SHANK NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />1 c s ,� <br />6. /3z 32/16 SPAN RATED OMB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />I DERSPECIFICATIONS ALLOW MIN <br />P D.. SHOULD BU L <br />D DIRECTLY TO OSB OR PLYWOOD.. , <br />N STUCCO LATH IS ATTACHE EC <br />BULLETIN 370 WHEN S Q <br />STRUCTURAL REQUIREMENTS ARE /6 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />7. 15/32" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, 15/2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />9. MINIMUM STRUCTURAL ROOF SHEATHING REQUIREMENTS FOR METAL ROOF CLADDING IS SAME AS SHINGLE ROOF. SHOULD ROOF <br />MANUFACTURER'S INSTALLATION DRAWINGS REQUIRE SPECIFIC ROOF SHEATHING EXCEEDING THE STRUCTURAL MINIMUM, <br />CONTRACTOR SHALL PROVIDE ROOF SHEATHING IN ACCORDANCE WITH ROOFING SPECIFICATIONS. <br />TABLE 4: NAIL SIZE LEGEND <br />NOTES 1 9 'i 4 <br />DIAMETER <br />LENGTH <br />8d COMMON <br />0.131" <br />2-'/2" <br />8d RINGSHANK <br />0.113" <br />2-%" <br />10d x 1- 1/2" <br />0.148" <br />1-'/1" <br />10d <br />0.131" <br />3" <br />10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3-'/4" <br />16d SINKER <br />0.148" <br />3-'/V <br />16d COMMON <br />0.162" <br />3-'/z" <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE <br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />TABLE 5: FASTENERS IN <br />PRESSURE TREATED LUMBER <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />Z-MAX, G120 OR TRIPLE ZINC <br />ALL OTHER PT <br />COATED FINISH. <br />(INCLUDING ACQ & MCQ) <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2.500 PSI AT 28 DAYS (UNO). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2" TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS, SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf IN <br />ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH APPROVED CHEMICAL SOIL TREATMENT FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10. TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 16x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED FLORIDA PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />2. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />3. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />4. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />5. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, <br />THIS SHEET. <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />NC)TF.S 9 3 4 <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />USP <br />USP FASTENERS <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />USP <br />USP FASTENERS <br />(8)%. X 1 W SDS SCREWS <br />(8)'Y." x 1'/z' WS15-GC <br />DTT2Z <br />IN STUDY2" 0 X 4'/2' <br />WOOD SCREWS IN STUD <br />(9) 10d COMMON <br />(9) 10d <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />'/Z 0 x 4'/i' EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />EACH END <br />(18)0.162"x2'/z"IN <br />(18)0.162"x2'/z"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MTS12 <br />(7) 10d x 1 1/-2" <br />MTW12 <br />(7) 10d x 1 1/2"(NOTE <br />2) <br />§8" 0 x 6" EMBED ANCHOR <br />fie„ 0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 WIN <br />(26) 0.162" x 2 '/2" IN <br />HTT5 <br />II <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />" <br />MSTA24 <br />(9) 10d COMMON <br />MSTA24 <br />(9) 10d COMMON <br />NOTE 2 <br />( ) <br />§" 0 x 6' EMBED ANCHOR <br />8 <br />4 8 0 x 6" EMBED ANCHOR <br />EACH END <br />EACH E ND <br />IN CONCRETE <br />IN CONCRETE <br />(20)'/." x 3" SDS SCREWS <br />(24) Y WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP 7//8" 0 x 12" EMBED <br />MSTA36 <br />(13) 10d COMMON <br />MSTA36 <br />(13) 10d COMMON <br />38" 0 x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />(7) 10d x 1 '/V IN TRUSS <br />(7) 10d x 1 '/i' IN TRUSS <br />(7) 10d COMMON IN <br />(7) 10d COMMON IN <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />MSTAM36 <br />WOOD FRAMING <br />(4) W x 2 'Y4" TITEN <br />MSTAM36 <br />WOOD FRAMING <br />(5) %" x 2 %" TAPCON IN <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />SCREWS IN MASONRY <br />MASONRY <br />(8) 10d x 1 W IN TRUSS <br />(9) 10d x 1 Y2" IN TRUSS <br />(11) 10d x 1 '/V IN <br />(11) 10d x 1 '/z" IN <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />(11) 10d x 1 1/2" IN <br />HTW20 <br />TRUSS/RAFTER <br />(11) 10d x 1 '/2" IN <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />STUD <br />STUD <br />(12) 10d x 1 /2 IN <br />, <br />(8 ) 10dx1/�„ IN <br />ABU44 <br />(12) 16d COMMON NAILS <br />PAU44 <br />(12) 16d COMMON NAILS <br />HTSM20 <br />TRUSS/RAFTER <br />HTWM20 <br />TRUSS/RAFTER <br />(NOTE 6) <br />48' 0 x 7" EMBED EPDXY <br />48' 0 x 7" EMBED EPDXY <br />, <br />(12) 10d x 1 /2„ IN <br />(4) /: x 3 WEDGE BOLT <br />STUD <br />OR EQUIVALENT IN STUD <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />(5) 8d x 1'/i' IN <br />(5) 8d x 1'/z" IN <br />ABU66 <br />%" 0 x 7" EMBED EPDXY <br />PAU66 <br />4 " 0 x 7" EMBED EPDXY <br />H2.5T/ <br />TRUSS <br />RT7/ <br />TRUSS <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />(12 EMBED AT GARAGE <br />HA8 <br />(5) 8d x 1 /2 IN <br />RT7AT <br />(5) 8d x 1 /Z IN <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />TOP PLATE <br />HU48, <br />(14) 16d COMMON IN <br />HD48, <br />(14) 16d COMMON IN <br />(5) 10d x 1'/2" IN <br />(5) 10d x 1'/2" IN <br />HUC48, <br />HU28-2 <br />HEADER <br />HD481F, <br />HD28-2, <br />HEADER <br />H8 <br />TRUSS <br />(5) 10d x 111/2" IN <br />RT8A <br />TRUSS <br />(5) 10d x 1 WIN <br />, <br />HUC28-2 <br />6 <br />() 10d COMMON IN BEAM <br />HD28-21F <br />(6) 10d COMMON IN BEAM <br />TOP PLATE <br />TOP PLATE <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />ITK <br />(16) 10d COMMON TO <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />LGT2 <br />TRUSS/RAFTER <br />LUGT2 <br />TRUSS/RAFTER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />(7) W x 2 W TITEN <br />(5)O" x 3" WEDGE BOLT <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />OR EQUIVALENT <br />(22) 16d COMMON IN <br />(22) 16d COMMON IN <br />(26) 16d SINKER <br />(28) 16d SINKER IN WALL <br />HUC212-2 <br />HEADER <br />HD212-21F <br />HEADER <br />LGT3 <br />WALL FRAMING <br />LUGT3 <br />FRAMING <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />(12) SDS '/:' x 2 '/:" <br />(1 <br />(12) WS25 '/;' x 2 '/z" <br />(4)%" x 1 '/2" SDS SCREW <br />(4) W x 1'Y2" WS15 SCREWS <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGAIOKT <br />(4)%" x 3" SDS SCREWS <br />HGA10 <br />(4) % x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, <br />SDWC15600 <br />NO <br />USP EQUIVALENT <br />(4) SDS %" x 1 '/2" SCREWS <br />(4) W x 1'/z" WS15 SCREWS <br />HGAM10KTA <br />IN TRUSS/RAFTER <br />HGAM10KT <br />IN TRUSS/ RAFTER <br />(4) Y," x 13/4" WEDGE BOLT <br />(4) W x 2W TITEN SCREWS <br />OR EQUIVALENT IN <br />L_ <br />IN MASONRY <br />MASONRY <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2017-2018 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2 Mz' LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />W 0 x 2 W TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF %" 0 x 1 %" TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. ENGINEER OF RECORD RECOMMENDS, BUT DOES NOT REQUIRE, ALL RUNNING BOND MASONRY WALLS TO BE EQUIPPED w/ 9 <br />GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT AT EVERY OTHER COURSE. <br />3. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />4. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 2,500 PSI. <br />5. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />6. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 25". <br />7. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING. <br />8. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />9. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />LEGEND o <br />OR "OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL <br />ALTERNATIVE FOR THE APPLICATION SHOWN E <br />LINO UNLESS NOTED OTHERWISE ON PLAN OR DETAIL O <br />FOR ENGINEER OF RECORD <br />EW EACH WAY O CY <br />OSB ORIENTED STRAND BOARD N O <br />WSP WOOD STRUCTURAL PANEL CN p <br />SYP SOUTHERN YELLOW PINE <br />E 04 APES <br />SPF SPRUCE -PINE -FUR <br />04 <br />U <br />CUNT CONTINUOUS 00 N <br />O.0 ON CENTER <br />LSL 1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 3/4" WIDE, UNO. 0) O0. <br />(3'/2" WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 3/4" BEAM) R? <br />LVL 2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 3/." WIDE <br />PSL 2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 ''/a" WIDE, UNO. <br />N <br />SYS 42 PROPERLY RATED OPEN WEB HEADER co <br />zzz <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS LL -C <br />�- OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETS LLI <br />INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM J td s uQ <br />BOTTOM PLATE ANCHORAGE IS ''/z" ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR true design studios 3: <br />SW SPECIFICATIONS) Z <br />STRUCTURAL WOOD BEAM O <br />STUD COLUMN KEYNOTE U 9000 REGENCY SQUARE BLVD. <br />Q SUITE 100, JACKSONVILLE, FL 32211 <br />-- ------ NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. _O <br />O <br />- - NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS <br />- TO MATCH WALL FRAMING SIZE AND GRADE, UNO, LU <br />12ANCHOR <br />STUDS U) wADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN co <br />N <br />T BOTTOM OF STUD COLUMN CONNECTION UsKeHOMN' <br />� <br />1ST LEVEL STUD COLUMN: HOLDDOWN REQUIRED AT BASE OF COLUMN <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL J r <br />COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. 00 <br />"ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN W � <br />NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE <br />Q <br />HEADER STRAPPING KEYNOTEC <br />NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD U) <br />C11 MSTA24 -- TYPE OF STRAP CONNECTING HEADER TO JACK STUD <br />D_TT2Z z <br />KING/JACK GROUP BOTTOM CONNECTION <br />W <br />1 ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP <br />- 2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD W <br />GROUP TO 1 ST LEVEL STUDS/HEADER/BEAM 0Y <br />-- NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP O <br />O <br />CD <br />NON -BEARING HEADER FRAMING KEYNOTE <br />NO C R_-4-- NUMBER OF KING STUDS EACH SIDE OF OPENING ~ <br />LA <br />- HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY r1_ <br />LOADED CONDITIONS ABOVE b U) <br />#2 SYP HEADER FRAMING KEYNOTE z w <br />(2) 2x10 - 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING W 9 Q N <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING Z <br />J Z 6L <br />w <br />DEPTH OF LOAD -BEARING #2 SYP HEADER O <br />NUMBER OF PLIES IN HEADER m Uj w <br />Qf <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE W Q <br />(2) 9%" LSI_- 1 / 2 --- NUMBER OF KING STUDS EACH SIDE OF OPENING w a <br />_Z <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING > Q Q <br />-- -HEADER MATERIAL (LSL, LVL, PSL, OR SYS42) w w <br />--- --- LLI <br />DEPTtI OF LOAD -BEARING EWP HEADER 0 Q W 2 <br />----- --- NUMBER OF PLIES IN HEADER (1 3/." WIDE UNO) 0 w w <br />HEADER FRAMING ° x <br />U. <br />1 ALL HEADER JACK AND KING STU DS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. <br />STAGGERED. 0 Z <br />2. NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN �. O <br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. Q <br />3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. W <br />4. FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS O 1-- <br />5. IF HEADER NOT SPECIFIED. CONTACT ENGINEER OF RECORD. z <br />6 LINO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE O a <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST U <br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. t=- <br />7. TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR Q <br />OPENINGS 39" OR LESS OR Al FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: J <br />� Abbott Park <br />• SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 O U <br />• SPH w/ (12) 10d x @ 16" O.C. OR J ---- -- - � <br />• DSP w/ (14) 10d x 1-'/2" @ 16" O C. OR LI_ LOT 007-01-A I:) <br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1-'/7' (OR EQUAL APPROVED BY EOR). Q __ W <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O.C. C� Q <br />z z <br />0 <br />FRAMING NOTES O PROJECT NO: LU <br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. J 2020.001717 <br />ANCHOR BOLT, THREADED ROD OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN O LI_ <br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). Z DRAWN'. O <br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S = SLC <br />SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. _ <br />O <br />2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFET H CHKD: <br />SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. EAF <br />3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN w w <br />TABLE 2304.9.1. a. J <br />4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER. Q U <br />5 FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. X ,,�������,I, 0 <br />SYSTEM TO FOUNDATIONUPPER LEVEL MULTI -PLY S (NOT REQUIRED BELOW HEADER JACK/KING TUD GROUPS BELOW ALL GIRDER NS TO BE ST D GROUPS) CONTINUOUS THROUGH FLOOR ``,��%�� IN LAME ���� <br />6 FASTEN ALL STUDS TO BOTTOM AND -TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. %" �� , .•• ••E N 9 �i 0 <br />7 FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. m `� ,• •�.� `SF• •• '�� Z <br />8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM 0% NO 51 6 <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, ONO. W <br />9 EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD z <br />r � , <br />ST E OF 441 <br />g '�'n • •'c P,. C� <br />O 02/25/2020 <br />i= w <br />U co <br />REVISIONS: <br />- - - <br />No. _Description Date w <br />J <br />>- U <br />O I-- <br />JO - z <br />z - -- - O <br />= o <br />U <br />w <br />I- <br />X <br />W STm1 <br />a. <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />