DESIGN CRITERIA AND LOADS
<br />TABLE 7: METAL CONNECTOR SCHEDULE
<br />P
<br />Building Code
<br />Florida Building and Residential Codes ,
<br />6ch Edition (2017)
<br />Code for Desiqn Loads
<br />ANSI/ASCE 7
<br />ROOF LOADING ...............................................
<br />Cd = 1.25
<br />TOP CHORD LIVE LOAD..................................20
<br />PSF
<br />TOP CHORD DEAD LOAD................................7
<br />PSF (TILE = 15 PSF)
<br />BOTTOM CHORD LIVE LOAD
<br />ATTICS WITH LIMITED STORAGE ...............
<br />20 PSF
<br />ATTICS WITHOUT STORAGE .......................10
<br />PSF
<br />(NON -CONCURRENT)
<br />BOTTOM CHORD DEAD LOAD..........
<br />5 PSF
<br />WIND LOADING .................................................
<br />Cd= 1.60
<br />ASCE 7-10, 3S GUST,.. ..............................
<br />...... 139 MPH
<br />BASIC WIND SPEED
<br />EXPOSURE CATEGORY ..................................
<br />C
<br />BUILDING CATEGORY .....................................
<br />11
<br />ENCLOSURE CLASSIFICATION- ....................
<br />ENCLOSED
<br />INTERNAL PRESSURE COEFF........................
<br />0.18
<br />C&C DESIGN PRESSURES ..............................
<br />(SEE TABLE 1)
<br />FLOOR LOADING ............. .......... .......................
<br />Cd = 1.00
<br />TOP CHORD LIVE LOAD..................................40
<br />PSF
<br />TOP CHORD DEAD LOAD................................10
<br />PSF
<br />BOTTOM CHORD LIVE LOAD ..........................
<br />0 PSF
<br />BOTTOM CHORD DEAD LOAD........................5
<br />PSF
<br />SPECIAL FLOOR GAME ROOM LOADING .... Cd = 1.00
<br />TOP CHORD LIVE LOAD ..................................
<br />60 PSF
<br />TOP CHORD DEAD LOAD................................10
<br />PSF
<br />BOTTOM B TTLIVE LOAD ...........................0
<br />O
<br />PSF
<br />O BOTTOM CHORD DEAD LOAD ........................
<br />O C
<br />5 PSF
<br />00 MAXIMUM FLOOR TRUSS SPACING...............16"
<br />U
<br />O.C.
<br />DEFLECTION CRITERIA
<br />LL / 240
<br />ROOF TRUSSES ..............................................
<br />TL / 180
<br />TL MAX 1" UP TO 40' SPAN
<br />FLOOR JOIST OR TRUSS ...............................
<br />LL / 480
<br />TL / 360
<br />BEAMS'............................................................LL
<br />/ 360
<br />TL/240
<br />NOTES:
<br />1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL
<br />ABOVE SHALL NOT EXCEED 3/4" DEFLECTION
<br />TABLE 1: COMPONENT AND
<br />CLADDING DESIGN PRESSURES
<br />WINDOWS AND DOORS
<br />EFFECTIVE
<br />WIND AREA
<br />ZONE DESIGNATION
<br />IZ - Interior Zone (psf)
<br />EZ - End Zone (psf)
<br />0 - 20 ft2
<br />+28.54 -30.96
<br />+28.54 -38.22
<br />21 - 50 ft2
<br />+27.17 -29.59
<br />+27.17 -3&47
<br />51 - 100 ft2
<br />+25.52 -27.94
<br />+25.52 -32.17
<br />101 - 200 ft2
<br />+24.25 -26.67
<br />+24.25 -29.64
<br />VINYL SOFFIT MAX PRESSURE (psf) +28.6 38.3
<br />GARAGE DOOR WIDTH'
<br />PRESSURE (PSF)
<br />+25.4/-32
<br />8 FT
<br />10 FT
<br />+25.02/-30.4
<br />16 FT
<br />+24.1 /-28
<br />18 FT
<br />+23.9/-27.5
<br />`GARAGE DOOR HEIGHT MAY BE 6'-8" OR HIGHER
<br />END ZONE KEY MAP
<br />END ZONE: END ZONES SHALL BE TAKEN
<br />AS THE 1 ST 4.0' PER FIGURE R301.2 (7)
<br />-_=_
<br />771
<br />1 ST FLOOR (TYP>
<br />END ZONE
<br />DESIGNATION
<br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS
<br />KinTFC 14
<br />p z
<br />STUCCO AND DIRECTLY
<br />MIN 15/ " 32i16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (�/6" 24/16
<br />Cr zF
<br />ADHERED STONE
<br />INSTALLED HORIZONTALLY) W/ 8d COMMON 6" O.C. AT PANEL EDGES, 12" O.C. IN THE
<br />N
<br />(NOTE 6)
<br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES.
<br />xQw
<br />w
<br />--
<br />Li t-
<br />O
<br />U
<br />ALL O-HER VENEER
<br />MIN %� " 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL
<br />(NOTE 8)
<br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES);
<br />6" O.C. AT PANEL EDGES, 12" O C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES)
<br />MIN '/,2" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION
<br />Y O
<br />U z
<br />TILE ROOF
<br />(NOTE 7)
<br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 4" O.C. AT PANEL EDGES AND
<br />o = w
<br />8" O C. IN THE FIELD
<br />UOLU z
<br />SHINGLE AND METAL ROOF
<br />MIN %6" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION
<br />T_
<br />(NOTE 9)
<br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 6" O.C. AT PANEL EDGES, 12"
<br />0
<br />O C. IN THE FIELD.
<br />FLOOR DECK,-' HEATHING:
<br />2%.2" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE
<br />(NOT; 5)
<br />FIELD.
<br />MIN %8" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d
<br />PORCH CEILING BOARD SHEATHING:
<br />COMMON: 3" O C. AT PANEL EDGES, 12" O.C. IN THE FIELD OR MIN %2" EXTERIOR GYPSUM
<br />CEILING BOARD, FASTEN w/ 5d x 1 %8" COOLER NAIL OR NQ.6 x 1 %4" LONG SCREWS @
<br />4" O.C. EDGES, 8" O.C. FIELD
<br />NOTES:
<br />1. FOR SHEATHING THICKNESS GREATER THAN 1%2" CATEGORY (32/16 SPAN RATING). USE 10d RING SHANK NAILS IN LIEU OF 8d RING
<br />SHANK NAILS. (0.148" x 3" LONG).
<br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS.
<br />WOOD STRUCTURAL PANEL.
<br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED N O
<br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF
<br />CURRENT APPROVED APA.MANF. SPECIFICATIONS.
<br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO HELP
<br />REDUCE HANK NAILS OR 8d SCR
<br />EW NAILS ARE RECOMMENDED.
<br />SQUEAKING, 8d RING S
<br />6. '%32" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL
<br />BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDERSPECIFICATIONS ALLOW , MIN
<br />STRUCTURAL REQUIREMENTS ARE'16" 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL
<br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS.
<br />7. 15/32" PLYWOOD IS A WARRANT`( LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY
<br />AND INSTALLATICN REQUIREMENTS ALLOW. ' /2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF.
<br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES.
<br />9. MINIMUM STRUCTURAL ROOF SHEATHING REQUIREMENTS FOR METAL ROOF CLADDING IS SAME AS SHINGLE ROOF. SHOULD ROOF
<br />MANUFACTURER'S INSTALLATION DRAWINGS REQUIRE SPECIFIC ROOF SHEATHING EXCEEDING THE STRUCTURAL MINIMUM,
<br />CONTRACTOR SHALL PROVIDE ROOF SHEATHING IN ACCORDANCE WITH ROOFING SPECIFICATIONS.
<br />TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN
<br />NOTES 1, 2, 3, 4 PRESSURE TREATED LUMBER
<br />--
<br />DIAMETER
<br />LENGTH
<br />8d COMMON �F_
<br />0 131"
<br />2-'/2"
<br />8d RINGSHANK
<br />10d x 1-'12"
<br />0.113"
<br />0.148"
<br />2 3/8"
<br />1 -'/2°
<br />10d
<br />0.131"
<br />3"
<br />10d COMMON
<br />0.148"
<br />3"
<br />12d COMMON
<br />0.148"
<br />3-'Yn" -
<br />16d SINKER
<br />0.148"
<br />3-14"
<br />16d COMMON
<br />0.162"
<br />3-'/2"
<br />NOTES
<br />PRESERVATIVE
<br />FASTENER TYPE
<br />ACZA
<br />STANDARD CARBON STEEL
<br />STAINLESS CONNECTORS AND
<br />SODIUM BORATE (NOTE 1)
<br />FASTENERS REQUIRED.
<br />CONNECTORS MUST HAVE
<br />Z-MAX. G120 OR TRIPLE ZINC
<br />ALL OTHER PT
<br />COATED FINISH.
<br />(INCLUDING ACQ & MCQ)
<br />ALL FASTENERS MUST BE HOT
<br />DIPPED GALVANIZED.
<br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED.
<br />NOTES:
<br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS
<br />1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON
<br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM
<br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY
<br />F1667 NOMINAL DIAMETER SIZES APPLY TO FASTENERS
<br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN
<br />BEFORE APPLICATION OF PROTECTIVE COATING.
<br />TO BE NON-CORROSIVETO CARBON STEEL FASTENERS.
<br />3. WHEN A BORED L-OLE IS REQUIRED TO PREVENT SPLITTING OF
<br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE
<br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER.
<br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS
<br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4.
<br />CONCRETE AND FOUNDATION NOTES
<br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO).
<br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO).
<br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO).
<br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE
<br />INSTALLED AT ALL REENTRANT CORNERS.
<br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2' TO 2" IN LENGTH.
<br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S
<br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE
<br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL.
<br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE.
<br />7. EARTH AND EAFTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2.000 psf IN
<br />ACCORDANCE WITH TABLE R401 4 1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS.
<br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR
<br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS.
<br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH
<br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WIT H APPROVED CHEMICAL SOIL TREATMENT FOR
<br />PREVENTION OF SUBTERRANEAN TERMITES.
<br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER
<br />OF RECORD IF THIS CONDITION EXISTS
<br />10. TO CONTROL CRACKING. CUT 1" SAWCUTS IN THE SLAB IN A i5'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT.
<br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NCT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED
<br />WITH CONCRETE- WORK.
<br />11, DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION
<br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF
<br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD.
<br />PRE-ENGINEERED TRUSSES & I -JOISTS
<br />1. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE
<br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS
<br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO
<br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET TEMPORARY BRACING SHALL BE THE
<br />RESPONSIBILITY' OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE.
<br />2. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION. SPAN DIRECTION, SPACING. BEARING & LOCATION OF
<br />THE FRAMING P!_AN SHOWN HERE.
<br />3. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM
<br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS.
<br />4. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN
<br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS
<br />MAY BE DISREGARDED.
<br />5. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND
<br />SUBMITTED TO --HE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA,
<br />THIS SHEET.
<br />NOTES 2 14
<br />MITEK & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE
<br />EQUAL ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE
<br />SIMPSON
<br />SIMPSON FASTENERS
<br />MITEK
<br />MITEK FASTENERS
<br />SIMPSON
<br />SIMPSON
<br />FASTENERS
<br />MITEK
<br />MITEK FASTENERS
<br />(8)'/4 X 1 %" SDS SCREWS
<br />(8)%" x 1'/2" WS15-GC
<br />DTT2Z
<br />IN STUDY2" O X 4'/2"
<br />WOOD SCREWS IN STUD
<br />(9) 10d COMMON
<br />(9) 10d
<br />(NOTE 2)
<br />EMBED EPDXY OR
<br />DTB-TZ
<br />'/2 O x 4'/2" EMBED EPDXY
<br />CS18
<br />EACH END
<br />CS20
<br />COMMON
<br />SCREW ANCHOR
<br />OR SCREW ANCHOR
<br />EACH END
<br />(18)0.162"x2'/2"IN
<br />(18)0.162"x2'/2"IN
<br />HTT4
<br />STUD/BEAM/TRUSS
<br />"
<br />HTT45
<br />STUD/BEAM/TRUSS
<br />"
<br />MTS12
<br />(7) 1Od x 1 M
<br />MTW12
<br />(7) 10d x 1 '/2"
<br />NOTE 2
<br />( )
<br />4 8 0 x 6" EMBED ANCHOR
<br />4 a 0 x 6" EMBED ANCHOR
<br />EACH END
<br />EACH END
<br />IN CONCRETE
<br />IN CONCRETE
<br />(26) 0.162" x 2 '/2" IN
<br />(26) 0.162" x 2 '/2" IN
<br />HTT5
<br />STUD/BEAM/TRUSS
<br />STUD/BEAM/TRUSS
<br />(9) 10d COMMON
<br />(9) 10d COMMON
<br />(NOTE 2)
<br />48" 0 x 6" EMBED ANCHOR
<br />HTT45
<br />�8„ O x 6" EMBED ANCHOR
<br />MSTA24
<br />EACH END
<br />MSTA24
<br />EACH END
<br />IN CONCRETE
<br />IN CONCRETE
<br />(20)%" x 3" SIDS SCREWS
<br />(24) 3" WS IN STUD
<br />HDQ8-SDS3
<br />IN STUD GROUP
<br />PHD8
<br />GROUP 7i8" 0 x 12" EMBED
<br />MSTA36
<br />(13) 10d COMMON
<br />MSTA36
<br />(13) 10d COMMON
<br />7///8" O x 12" EMBED
<br />ANCHOR IN CONCRETE
<br />EACH END
<br />EACH END
<br />ANCHOR IN CONCRETE
<br />(7) 10d x 1 %" IN TRUSS
<br />(7) 10d x 1 '/V IN TRUSS
<br />(7) 10d COMMON IN
<br />(7) 10d COMMON IN
<br />META12
<br />4" WET EMBED IN
<br />HTA16-18
<br />4" WET EMBED IN
<br />MSTAM36
<br />WOOD FRAMING
<br />MSTAM36
<br />WOOD FRAMING
<br />GROUTED BLOCK WALL
<br />GROUTED BLOCK WALL
<br />(4) ,/<" x 2 '/4" TITEN
<br />(5) '/4" x 2 '/;' TAPCON IN
<br />SCREWS IN MASONRY
<br />(11) 1Od x 1 '/V IN
<br />MASONRY
<br />(11) 10d x 1 '/2" IN
<br />(8) 10d x 1 '/2" IN TRUSS
<br />(9) 10d x 1 Y2" IN TRUSS
<br />META20
<br />4" WET EMBED IN
<br />HTA20-18
<br />4" WET EMBED IN
<br />HTS20
<br />TRUSS/RAFTER
<br />HTW20
<br />TRUSS/RAFTER
<br />GROUTED BLOCK WALL
<br />GROUTED BLOCK WALL
<br />(11) 1Od x 1 '/2" IN
<br />(11) 10d x 1 '/2" IN
<br />STUD
<br />(12) 10d x 1 1/2" IN
<br />STUD
<br />(8)10dx1Y2"IN
<br />ABU44
<br />(12) 16d COMMON NAILS
<br />(12) 16d COMMON NAILS
<br />TRUSS/RAFTER
<br />NOTE 6
<br />4 " x 7" EMBED EPDXY
<br />8 Q
<br />PAU44
<br />� x 7" EMBED EPDXY
<br />8 O
<br />HTSM20
<br />12 10dx1 /2"IN
<br />( )
<br />HTWM20TRUSS/RAFTER
<br />(4)1/4" x 3" WEDGE BOLT
<br />STUD
<br />(5) 8d x 1'/2" IN
<br />OR EQUIVALENT IN STUD
<br />(5) 8d x 1'/2" IN
<br />(12) 16d COMMON NAILS
<br />(12) 16d COMMON NAILS
<br />ABU66
<br />48" O x 7" EMBED EPDXY
<br />PAU66
<br />§8 0 x 7" EMBED EPDXY
<br />H2.5T/
<br />TRUSS
<br />RT7/
<br />TRUSS
<br />(NOTE 6)
<br />(12" EMBED AT GARAGE
<br />(12 EMBED AT GARAGE
<br />HA8
<br />(5) 8d x 1 /2" IN
<br />RT7AT
<br />(5) 8d x 1 /2" IN
<br />DOOR RETURNS)
<br />DOOR RETURNS)
<br />TOP PLATE
<br />(5) 10d x 1'/2" IN
<br />TOP PLATE
<br />(5) 10d x 1'/2" IN
<br />HU48,
<br />(14) 16d COMMON IN
<br />HD48,
<br />(14) 16d COMMON IN
<br />HUC48,
<br />HEADER
<br />HD481F,
<br />HEADER
<br />H8
<br />TRUSS
<br />RT8A
<br />TRUSS
<br />HU28-2,
<br />(6) 10d COMMON IN BEAM
<br />HD28-2,
<br />(6) 10d COMMON IN BEAM
<br />(5) 10d x 1'/2" IN
<br />(5) 10d x 1'/2" IN
<br />HUC28-2
<br />HD28-21F
<br />TOP PLATE
<br />TOP PLATE
<br />(16) 1Od COMMON TO
<br />HU410,
<br />(18) 16d COMMON IN
<br />HD410,
<br />(18) 16d COMMON IN
<br />HUC410,
<br />HEADER
<br />HD4101F,
<br />HEADER
<br />TRUSS/RAFTER
<br />TRUSS/RAFTER
<br />HU210-2,
<br />(10) 10d COMMON IN
<br />HD210-2,
<br />(10) 10d COMMON IN
<br />LGT2
<br />(7) ,/4" x 2 'W' TITEN
<br />LUGT2
<br />(5)'0" x 3" WEDGE BOLT
<br />HUC210-2
<br />BEAM
<br />HD210-21F
<br />BEAM
<br />SCREWS IN MASONRY
<br />OR EQUIVALENT
<br />(22) 16d COMMON IN
<br />(22) 16d COMMON IN
<br />(26) 16d SINKER
<br />(28) 16d SINKER IN WALL
<br />HUC212-2
<br />HEADER
<br />HD212-21F
<br />HEADER
<br />LGT3
<br />WALL FRAMING
<br />LUGT3
<br />FRAMING
<br />10 10d COMMON IN BEAM
<br />10 10d COMMON IN BEAM
<br />(12) SDS '/4" x 2 '/2"
<br />(1
<br />(12) WS25 '/4" x 2 '/2"
<br />(4)'/4" x 1 '/2" SDS SCREW
<br />(4) '/4" x 1'/2" WS15 SCREWS
<br />IN TRUSS
<br />IN TRUSS
<br />IN TRUSS/RAFTER
<br />IN TRUSS/ RAFTER
<br />HGA10KT
<br />(4)%" x 3" SDS SCREWS
<br />HGA10
<br />(4) 'W x 3" WS3 SCREWS
<br />IN TOP PLATE
<br />IN TOP PLATE
<br />SDWC14500,
<br />SDWC15600
<br />NO
<br />MITEK EQUIVALENT
<br />(4) SIDS x 1 '/V SCREWS
<br />(4)' "
<br />HGAM10KT
<br />IN TRUSS/RAFTER
<br />HGAM10KT
<br />IN TRUSS/ RAFTEREWS
<br />3
<br />(4) /4 x 1 /4 WEDGE BOLT
<br />(4)'/4" x 23/4" TITEN SCREWS
<br />IN MASONRY
<br />OR EQUIVALENT IN
<br />ji
<br />MASONRY
<br />NOTES:
<br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS.
<br />2. PRODUCTS SELECTED USING SIMPSON 2017-2018 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES
<br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS.
<br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS.
<br />5. POSITIVE PLACEMENT GUN NAILS, 2 '/2" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR
<br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS.
<br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES
<br />%" 0 x 2 3/" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF %" O x 1 3/4" TITENS ILO 16d.
<br />MASONRY NOTES
<br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL
<br />BED.
<br />2. ENGINEER OF RECORD RECOMMENDS, BUT DOES NOT REQUIRE, ALL RUNNING BOND MASONRY WALLS TO BE EQUIPPED w/ 9
<br />GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT AT EVERY OTHER COURSE.
<br />3. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER
<br />TYPE HORIZONTAL JOINT REINFORCEMENT
<br />4. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 2,500 PSI.
<br />5. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR.
<br />6. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 25".
<br />7. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING .
<br />8. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET.
<br />9. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE.
<br />LEGEND
<br />OR
<br />"OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL
<br />ALTERNATIVE FOR THE APPLICATION SHOWN
<br />UNO
<br />UNLESS NOTE 071 -LIER1v1ASE ON PLAN OR DETAIL
<br />FOR
<br />ENGINEER OF RECORD
<br />EW
<br />EACH WAY
<br />OSB
<br />ORIENTED STRAND BOARD
<br />WSP
<br />WOOD STRUCTURAL PANEL
<br />SYP
<br />SOUTHERN YELLOW PINE
<br />SPF
<br />SPRUCE -PINE -FUR
<br />CONT
<br />CONTINUOUS
<br />O C
<br />ON CENTER
<br />LSL
<br />1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 3/4" WIDE, UNO.
<br />(3 'i2" AiIDE L.SL BEAMS ARE EQUIVALENT 1-0 2-PLY 1 3/4" BEAM)
<br />LVL
<br />2.0E MICROLLAM LVL ENGINEERED LUMBER 1 '/" WIDE
<br />PSL
<br />2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 %2" WIDE, UNO.
<br />SYS 42
<br />PROPERLY RATED OPEN WEB HEADER
<br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS
<br />OUTLINED :)N TYPICAL WALL SECTIONS; DETAIL SHEETS
<br />INTERIOR SEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM
<br />BOTTOM PLATE ANCHORAGE IS %2" ANCHOR @ 8'-0" Q.C. (UNO ON FRAMING PLAN OR
<br />SW SPECIFICATIONS)
<br />I I. _1 1 UR ;L IfJOQD BEAr1
<br />STUD COLUMN KEYNOTE
<br />-
<br />- NUMBER OF SuWC 15600 CONNECTING TOP PLATE TO STUDS.
<br />NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS
<br />� TO MATCH
<br />H WALL FRAMING SIZE AN
<br />D GRADE. UNO.
<br />I
<br />2 2 STUDS i C/) ��
<br />o - ADDITIONAL_ CLARITY FOR THE LOCATION OF THE STUD COLUMN
<br />2 ANCHOR 0
<br />BOTTOM OF STUD COLUMN CONNECTION
<br />------------- 1ST LEVEL STUD COLUMN HOLDDOWN REQUIRED AT BASE OF COLUMN
<br />2ND LEVEL S TUD COLUMN STRAPPING REQUIRED FROM 2ND LEVEL
<br />COLUMN TO 1 ST LEVEL STUDS,`HEADEWIBEAM
<br />L- - 'ANCHOR'REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN
<br />- NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE
<br />HEADER STRAPPING KEYNOTE
<br />r --- NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD
<br />-rASTA�4 - TYPE OF STRAP CONNECTING HEADER TO JACK STUD
<br />�� (1--- KLNG/JACK ')'R(.`,UP BOTTOM CONNECTION
<br />1 ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP
<br />-- 2ND LEVEL S TUC) COLUMN STRAPPING REQUIRED FROM 2ND LEVEL STUD
<br />GROUP 70 1 ST LEVEL STUDS/HEADER/BEAM.
<br />- NUMBER OF HOLDDOWNS'STRAPS AT BASE OF KING/JACK GROUP
<br />NON_BEARING_HEADER FRAMING KEYNOTE
<br />NO HDR - #-�---- NUMBER OF KING STUDS EACH SIDE OF OPENING
<br />- HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY
<br />LOADED CONDITIONS ABOVE
<br />_ #2 SYP HEADER FRAMING KEYNOTE
<br />12) 2x10 - 1 : 2--�!--- NUMBER C)I7 KING STUDS EACH SIDE OF OPENING
<br />-- NUMBER OF .TACK STUDS EACH SIDE OF OPENING
<br />- - DEPTH OF LCAD-BEARING #2 SYP HEADER
<br />---- NUMBER OFPLIES IN HEADER
<br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE
<br />I (2) 9'/-,." LSL- 1/ 241 -- NUMBER OF KING S7 UDS EACH SIDE OF OPENING
<br />---- NUMBER OF JACKSTJDS EACH SIDE JC PE
<br />NiNG
<br />-----HEADER MATERIAL (LSL, LVL, PSL, OR SYS42)
<br />-- DEPTH OF LOAD -BEARING EWP HEADER
<br />NUMBER OF PLIES IN HEADER (1 '/" WIDE UNO)
<br />HEADER FRAMING
<br />1 ALL HEADER JACK AND KING STU DS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C.
<br />STAGGERED.
<br />2 NON BEARING HEADERS DUE TO LIGHTLY LOADED CONDITIONS, 38" OR LESS CLEAR -OPENINGS IN AN
<br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN.
<br />3 FASTEN ALL MUL T 1-PLY HEADERS TOGETHER WITH '2) ROWS 1 Od @ 8" O.C.. STAGGERED ALONG EACH EDGE.
<br />4 FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS
<br />5 IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD.
<br />6 UNO ON PLAN, MIN (1) SDWC i5600 TOP PLT TO KING STUD AND (1) SDVVC15450 KING STUD TO BOTTOM PLATE
<br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST
<br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE.
<br />7 TOP PLATE TO HEADER v'ONNEC T ION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR
<br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE:
<br />• SDW'C15600 @ MAX 32' O.0 AS SHOWN, 'ALTERNATE SECTION (HEADERS) ST-5
<br />•SPH'.^'02i IOdx1-'.-z @ 16O
<br />•DSPw/(1411i)dx1-Y2"i^16' O.0 OR
<br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 1 Od x 1-/" (OR EQUAL APPROVED BY EOR).
<br />8 CRIPPLE BLOCKS BELOW LCAD-BEARING HEADERS MAYBE FRAMED AT 24" QC.
<br />FRAMING NOTES
<br />I-
<br />O
<br />z
<br />W
<br />z
<br />m
<br />W
<br />W
<br />z_
<br />O
<br />z
<br />W
<br />❑
<br />O
<br />J
<br />IL
<br />Z
<br />O
<br />O
<br />0-
<br />0
<br />❑
<br />O
<br />J
<br />L�
<br />Q
<br />z
<br />0
<br />O
<br />W
<br />1-
<br />W
<br />W
<br />X
<br />Lli
<br />z
<br />O
<br />W
<br />Q
<br />z
<br />U)
<br />Z)
<br />O
<br />H
<br />U
<br />LL
<br />0
<br />O
<br />J
<br />O
<br />z
<br />U
<br />W
<br />W
<br />Q
<br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS .
<br />ANCHOR BOLT THREADED ROD. OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN
<br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER).
<br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S
<br />SPECIFICATIONS MUST BE FOLLO`. %ED FOL: PROPER INSTALLATION.
<br />2 .ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY
<br />SYSTEMS ARE THE RESPONSIBILITY OL T HE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER.
<br />3. ALL. METAL CONNECTORS SPECIFIED ON PLAN ARE IN .ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN
<br />TABLE 2304.9.1.
<br />4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER.
<br />5 FASTEN ALL MULTI -PLY STUD COLUP"1NS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED.
<br />UPPER LEVEL MULTI -PLY 81 UD GROUPS BELOW .ALL. GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR
<br />SYSTEM TO FOUNDAT!ON. ("TJjT REQUIRED BEL-O'�N HEADER JACK,'K,ING STUD GROUPS)
<br />6. FASTEN ALL STUDS TO SOTTO!'A AND TC'P PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS.
<br />FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES'V'dITH (3)8d TOE NAILS.
<br />8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM
<br />THICKNESS AND MATCHING ! ✓.ALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN. UNO.
<br />9. EXTERIOR 'A%ALL DESIGN ASSUMF-S CONTiNUOUSLY SHEATHED V^JI -H OSB OR PLYWOOD
<br />�i
<br />tds
<br />true design studios �
<br />9000 REGENCY SQUARE BLVD.
<br />SUITE 100, JACKSONVILLE, FL 32211
<br />904.821.5200
<br />_p
<br />-
<br />�3
<br />� It
<br />1 MON
<br />�
<br />a J4-
<br />ha 5 , ,
<br />.Q
<br />N
<br />mi
<br />Uj
<br />�
<br />w
<br />�
<br />Z
<br />w
<br />Q
<br />O
<br />cn
<br />j
<br />O
<br />�
<br />w
<br />�
<br />�
<br />w
<br />�J
<br />III
<br />ti
<br />X
<br />z
<br />O
<br />z
<br />Abbott Park
<br />U_
<br />LOT 006-01-A w
<br />J
<br />U
<br />W
<br />PROJECT NO F-
<br />2020.001716 z
<br />DRAWN:
<br />SLC w
<br />❑
<br />CHKD. EAF U_
<br />O
<br />O
<br />W
<br />J
<br />% U
<br />U)
<br />0
<br />z
<br />Cn
<br />02-25-2020 O
<br />z
<br />REVISIONS: <
<br />No. Description Date ❑
<br />w
<br />w
<br />z
<br />w
<br />J
<br />Q
<br />U
<br />0
<br />STm1 1-
<br />O
<br />z
<br />O
<br />i MIIIMFTAI ('.ONNF(:TOR FN(,INFFRIN[,
<br />
|