My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8016 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8016 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:20:15 AM
Creation date
2/27/2025 1:15:45 PM
Metadata
Fields
Template:
Building Plans
Street #
8016
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
22777
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'I 1 1 1 1' I 'II 1 11 F 1 1 -111A = r 1 1 1 <br />_ 1 1 11 . Tr w� r. .r• _ <br />r- <br />Footer <br />Re -Bar (sized <br />according to j <br />foundation plan) ° <br />#4 awg CU bare w/ 10' stubbed j <br />outside of slab at service 1 a o <br />location. Connect to footer steel ' <br />w/ (2) ground clamps 5' apart _ <br />a --- ------.a i <br />LIFER GROUND DETAIL <br />N.T.S. — --- -- <br />GENERAL ELECTRICAL NOTES <br />ALL ELECTRICAL DESIGN AND WORK SHALL BE IN STRICT 1 <br />COMPLIANCE WITH THE 2014 NATIONAL ELECTRIC CODE <br />• PER NEC SECTION 210.12 (B) ALL 15A & 20A, 120V <br />BRANCH CIRCUITS SUPPLYING OUTLETS REQUIRE <br />AFCI PROTECTION <br />• CARBON MONOXIDE PROTECTION PER FLORIDA <br />STATUTES 553.885 (2). TO BE INSTALLED WITHIN 10' <br />OF EVERY SLEEPING ROOM <br />i <br />• ALL OUTLETS SHOULD BE AFCI PER NEC - U.N.O. <br />PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />RECEPTACLES INSTALLED OUTDOORS MUST BE <br />GFCI-PROTECTED <br />• PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />RECEPTACLES INSTALLED WITHIN 6' OF SINK (IN <br />NON -DWELLING OCCUPANCIES-i.e. OUTDOOR <br />SUMMER KITCHENS RECEPTACLES) MUST BE <br />GFCI-PROTECTED <br />ELECTRICAL RISER DIAGRAM <br />OPTIONAL OVERHEAD PER NEC SECTION 406.8(B)(1) 15A & 20A <br />SERVICE SAME AS RECEPTACLES IN A WET LOCATION MUST BE WITHIN <br />UNDERGROUND 150 OR 200 — 150 = #1 Copper or 2/ 0 Aluminum AN ENCLOSURE THAT IS WEATHERPROOF WHEN AN <br />AMP SERVICE 200 = 2 /0 Copper or 4 /0 Aluminum in 2" ATTACHMENT IS PLUGGED IN AN ALL NON -LOCKING <br />Conduit. A/C DISCONNECT RECEPTACLES SHALL BE LISTED AS WEATHER <br />RESISTANT <br />METER <br />MAIN . PER NEC SECTION 406.11 IN DWELLING UNITS, ALL <br />DISC. J_j �_ #12 COPPER TO APPLIANCES AND GFI <br />150 OR 15A & 20A, 15V RECEPTACLES SHALL BE LISTED AS <br />200 AMP TYPICAL TAMPER -RESISTANT <br />ELECTRICAL #14 COPPER TO LIGHTS AND OUTLETS <br />_.: PANEL . PER NEC SECTION 800.156 NO LESS THAN ONE <br />UNDGND — #10 COPPER TO WATER HEATER <br />SERV. BY - #8 COPPER TO RANGE COMMUNICATION OUTLET SHALL BE INSTALLED <br />POWER CO. — #6 COPPER TO HVAC WITHIN EACH DWELLING UNIT <br />N.T.S. _ #4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER: • PER NEC SECTION R314.3 AND R315.1 SMOKE <br />A) APPROVED GROUNDING ROD WITH MINIMUM 8' DEPTH DETECTORS TO BE INSTALLED INSIDE EACH <br />B) BONDED TO CONTINUOUS FOOTING STEEL SLEEPING AREA <br />-- INTERSYSTEM BONDING TERMINATION PER NEC 250.94 • ALL SMOKE ALARMS SHALL BE LISTED AND LABELED <br />IN ACCORDANCE WITH UL 217, PER FBC 314.1. GC TO <br />NOTE: INSTALL. KIDDE MODEL # 14618A SMOKE ALARM, OR <br />ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE APPROVED EQUAL <br />PROVISIONS OF THE NFPA 70, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />_- — _ • PROVIDE GAS DROPS AS PER COMMUNITY ONLY <br />• JUNCTION BOX AT WATER HEATER, RANGE AND/OR <br />DRYER TO BE 220V IN NON GAS COMMUNITIES, AND <br />110V IN COMMUNITIES THAT HAVE GAS OPTIONS <br />PROVIDE APPROPRIATE RECEPTACLE PER <br />APPLIANCE <br />• ALL LAMPS SHALL BE HIGH -EFFICACY TO COMPLY <br />WITH FBC-EC R404.1 - (LOW -VOLTAGE LAMPS <br />EXCLUDED). <br />• PER FBC-R M1305.1 A LEVEL WORKING SPACE NOT <br />LESS THAN 30" DEEP AND 30" WIDE SHALL BE <br />PROVIDED IN FRONT OF THE CONTROL SIDE OF ANY <br />APPLIANCE <br />ABBREVIATIONS LEGEND <br />ABV <br />ABOVE <br />AC <br />AIR CONDITIONER <br />AFF <br />ABOVE FINISHED FLOOR <br />AHU <br />AIR HANDLER UNIT <br />BILK <br />BLOCK <br />CABS <br />CABINETS <br />CLG <br />CEILING <br />CHR <br />CHAIR RAIL <br />COFF <br />COFFERED <br />COL <br />COLUMN <br />COND <br />CONDENSER <br />CRN <br />CROWN MOULDING <br />CVAC <br />CENTRAL VACUUM SYSTEM <br />DBL <br />DOUBLE <br />DIAG <br />DIAGONAL <br />DR <br />DOOR <br />DRY <br />DRYER <br />DW <br />DISHWASHER <br />EB <br />EYEBROW <br />FL <br />FLOOR LINE (MAT. CHANGE) <br />FLR <br />FLOOR <br />FP <br />FIREPLACE <br />FXD <br />FIXED <br />FXT <br />FIXTURE <br />GLS <br />GLASS <br />HB <br />HOSE BIB <br />KS <br />KNEE SPACE <br />LAV <br />LAVATORY <br />LT <br />LAUNDRY TUB <br />MRBL <br />MARBLE <br />MC <br />MEDICINE CABINET <br />MIR <br />MIRROR <br />MTL <br />METAL <br />OH <br />OVERHEAD <br />OPNG <br />OPENING <br />OPT <br />OPTIONAL <br />R & S <br />CLOTHES ROD and SHELF <br />REF <br />REFRIGERATOR <br />SD <br />SOAP DISH <br />SDLTS <br />SIDE LIGHTS <br />SGD <br />SLIDING GLASS DOOR <br />SH (2) <br />SHELVES (QUANTITY) <br />SHWR <br />SHOWER <br />TB <br />TOWEL BAR <br />TPH <br />TOILET PAPER HOLDER <br />T&S <br />TUB and SHOWER <br />TEMP <br />TEMPERED <br />TR <br />TRANSOM <br />VOL <br />VOLUME <br />WC <br />WATER CLOSET <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />WNCT <br />WAINSCOT <br />WS <br />WATER SOFTENER <br />WASH <br />WASHER <br />- ---- - ---- - - - - - -- - 0 <br />ROOF NOTES EXTERIOR ELEVATION GENERAL NOTES GENERAL NOTES <br />• INSTALL ROOF VENTING PER MFR WRITTEN 1 1 ALL CONSTRUCTION SHALL MEET THE LATESTCY <br />INSTRUCTIONS PER FBC R806 • FRONT ELEVATIONS TRIM, MOLDING, COLUMNS j p <br />TRIM SHALL RECEIVE A PAINTED FiNiSH PER EDITION OF CODES ADOPTED BY THE LOCAL O <br />• ALL OVERHANG DIMENSIONS ARE TO EDGE OF BLDR SPECS. SEE ELEVATION FOR DEPTH OR GOVERNING AGENCIES Z A-N-- <br />AND i <br />RAFTER. REFERENCE WALL SECTIONS/DETAILS RAISED TRIM I 0 <br />FOR ALL OVERHANGS NOT DIMENSIONED. PER FBC R302.5 NO OPENINGS FROM A PRIVATE w <br />• SIDE AND REAR ELEVATIONS TRIM AROUND <br />WINDOWS AND DOORS MAY BE OPTIONAL PER GARAGE ARE PERMITTED DIRECTLY INTO SLEEPING Z (D <br />• ALL UNDERLAYMENT MUST BE INSTALLED IN COMMUNITY SPECS - SEE COMMUNITY AREAS. ALL OPENINGS SHALL HAVE SOLID WOOD, <br />COMPLIANCE WITH FBC R501.1.1 <br />SPECIFICATIONS OR CONSULT THE INSULATED STEEL OR 20 MIN. FIRE RATED DOORS 00 <br />• CONSTRUCTION MANAGER. ALL TRIM SHALL i NOT LESS THAN 1-3/8 INCHES THICKNESS, EQUIPPED <br />EACH 4' OFF RIDGE VENT REQUIRES 1 <br />() 46" x 3" CUT RECEIVE A PAINTED FINISH PER BLDR SPECS WITH A SELF CLOSING DEVICE. ALL DUCTS IN THE Of <br />OUT IN ROOF SHEATHING PER MFR WRITTEN LU <br />INSTRUCTIONS ROOF COVERING SEE COMMUNITY GARAGE OR PENETRATING THE WALL OR CEILING w <br />• SPECIFICATIONS OR CONSULT THE SEPARATING THE GARAGE AND DWELLING SHALL BE Z <br />CONSTRUCTION MANAGER. SEE STRUCTURAL CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1 INCH (D <br />SHEETS FOR SHEATHING REQUIREMENTS MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD, OR W <br />OTHER APPROVED MATERIAL AND SHALL HAVE NO <br />true design studios <br />FLASHING SHALL BE INSTALLED AT WALL AND OPENINGS INTO THE GARAGE �j <br />ROOF INTERSECTIONS; DECK AND WALL <br />INTERSECTIONS. AT GUTTERS. AT ALL CHANGES IN • PER FBC TABLE R-302.6 GARAGE SHALL BE <br />ROOF SLOPE OR DIRECTION, AND AROUND ROOF O <br />OPENINGS SEPARATED FROM RESIDENCE AND IT'S ATTIC W/ J 9000 REGENCY SQUARE BLVD. a) <br />MIN. 1/2" GYP BOARD ATTACHED IN ACCORDANCE U- SUITE 100, JACKSONVILLE, FL 32211 <br />• WALL HEIGHTS VERIFY ALL BEARING WALL WITH TABLE R702.3.5. HABITABLE ROOMS SHALL BE O 904.821.5200 p <br />HEIGHTS WITH FINAL TRUSS LAYOUTS SEPARATED FROM ROOM ABOVE W/ MIN 5/8" TYPE — <br />"X" GYP BOARD, WHERE THE SEPARATION IS A <br />• WATER -RESISTIVE BARRIERS PER R703.7.3. FLOOR -CEILING ASSEMBLY. ANY STRUCTURE w <br />WATER -RESISTIVE BARRIERS SHALL BE INSTALLED SUPPORTING THE ASSEMBLY SHALL BE PROTECTED O CY <br />AS REQUIRED IN SECTION R703.2 AND, WHERE W/ MIN 1/2" GYP BOARD D- b <br />- -- -- - APPLIED OVER WOOD -BASED SHEATHING, SHALL O�,�� <br />ROOF VENT CALCULATION INCLUDE AWATER-RESISTIVE VAPOR -PERMEABLE • PER FBC R302.12 IN COMBUSTIBLE CONSTRUCTION 0 � <br />BARRIER WITH A PERFORMANCE AT LEAST s <br />- EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. WHERE THERE IS USEABLE SPACE BOTH ABOVE Q <br />FORMULA: THE INDIVIDUAL LAYERS SHALL BE INSTALLED AND BELOW THE CONCEALED SPACE OF A 0 <br />INDEPENDENTLY SUCH THAT EACH LAYER ! FLOOR/CEILING ASSEMBLY, DRAFT STOPS SHALL BE <br />1 SQUARE INCH VENT FOR EVERY 300 SQUARE INCHES PROVIDES A SEPARATE CONTINUOUS PLANE AND INSTALLED SO THAT THE AREA OF THE CONCEALED O <br />OF CEILING ANY FLASHING (INSTALLED IN ACCORDANCE WITH SPACE DOES NOT EXCEED 1,000 SQUARE FEET.LL <br />J <br />*144 SQ. IN. = 1 SQ. FT. SECTION R703.4) INTENDED TO DRAIN TO THE <br />BLDG. CEILING (SF) x 144 -BLDG (SQ. IN.) WATER -RESISTIVE BARRIER IS DIRECTED DRAFT STOPPING SHALL DIVIDE THE CONCEALED Q <br />BETWEEN THE LAYERS SPACE INTO O APPROXIMATELY EQUAL AREAS AND <br />BLDG. (SQ. IN.) 1300 = SQ. IN. OF VENT REQUIRED INSTALLED PER FBC R302.12 & R302.12.1 0 <br />SQ. IN. OF VENT REQUIRED / 2 = 50% AT HIGH AND 50% Z <br />AT LOW. <br />• PER FBC R-312. 1 PORCHES, BALCONIES OR RAISED PER FBC SECTION R806.2: 40% MIN, BUT NOT MORE FLOOR SURFACES LOCATED MORE THAN 30" ABOVE U' <br />THAN 50% OF VENTILATION MUST BE PROVIDED BY FINISHED FLOOR OR GRADE SHALL HAVE GUARDS 0 <br />VENTILATORS LOCATED NO MORE THAN 3'-0" BELOW NOT LESS THAN 36" IN HEIGHT. PER FBC R-312.1.2 O <br />THE RIDGE OR HIGHEST POINT OF THE SPACE OPEN SIDES OF STAIRS WITH A TOTAL RISE OF Z <br />MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE 2 <br />BASIS OF CALCULATION: ("OR EQUAL" ACCEPTABLE) SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT W <br />MEASURED VERTICALLY FROM THE NOSING OF THE <br />(a) OFF RIDGE VENTS - STAMPCO W/ 36 SQ IN (NFVA) 1 TREADS X <br />PER LINEAL FT w <br />(b) SOFFIT VENTS - GP T3-1/3" FULL VENT PERFORATED PER FBC ft-312.1.3 REQUIRED GUARDS ON OPEN Q U) <br />SIDES OF STAIRWAYS, RAISED FLOOR AREAS, W <br />W/ 9.19 SQ IN (NFVA) PER LINEAL FT X W <br />BALCONIES AND PORCHES SHALL HAVE <br />CALCULATED LINEAL FOOT OF SOFFIT VENT SHALL j INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES <br />NOT INCLUDE NON -VENTED FIRE RATED SOFFIT ! WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" <br />LOCATED LESS THAN 5' FROM PROPERTY LINE OR MORE IN DIAMETER m <br />z o = rWn <br />• PER FBC R-308.4.5 GLAZING IN WALLS, ENCLOSURES Z O v, <br />OR FENCES CONTAINING OR FACING HOT TUBS, �} <br />j SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, O <br />BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR w Q O <br />j SWIMMING POOLS WHERE THE BOTTOM EXPOSED <br />EDGE OF THE GLAZING IS LESS THAN 60 INCHES Z Q <br />MEASURED VERTICALLY ABOVE ANY STANDING OR W W <br />WALKING SURFACE, SHALL BE CONSIDERED A : J <br />HAZARDOUS LOCATION. G.C. TO VERIFY IF W <br />- - -- - - - HOMEOWNER SELECTS ANY OF THESE ITEMS � W QQ_ <br />LISTED. IF ANY OF THESE ITEMS LISTED IS <br />INSTALLED, SUCH GLAZING FACING THOSE ITEMS IS 0 LL w <br />TO BE TEMPERED <br />Q f� <br />• PER FBC R312.2, PROVIDE WINDOW FALL U) X <br />PROTECTION IN ACCORDANCE WITH R312.2.1 AND } <br />R312.2.2 <br />O ZO <br />• GAS OPT. PER COMMUNITY. VERIFY WITH BLDR O <br />Z <br />LLI <br />• C.J. = RECOMMENDED MASONRY CONTROL JOINT 2 <br />LOCATION U Z <br />Uj <br />Abbott Park <br />o ALL FINISHES, MATERIALS, HOUSEWRAP, WINDOW 11 <br />AND DOOR FLASHING, TAPING AND SEALANTS TO BE W U- <br />INSTALLED PER BUILDER PROVIDED Q LOT 006-01-A w <br />SPECIFICATIONS OR MFR WRITTEN INSTRUCTIONS — -- -j <br />U <br />ALL FINISH DETAILS & TYPICAL PLAN NOTES (� <br />PROVIDED BY BUILDER IN ACCORDANCE WITH p <br />TYPICAL BUILDER SPECIFICATIONS UJ <br />PROJECT NO: I- <br />• REFER TO STRUCTURAL ENGINEERING DRAWINGS 2020.001716 Z <br />FOR ALL EXTERIOR WALL STUD SPECIES, SIZES AND 0 <br />SPACING DRAWN: W <br />SLC w <br />CHKD: <br />JAC O <br />0 <br />0 <br />u7 <br />co <br />w <br />J <br />Q <br />U <br />fn <br />U) <br />(D <br />Z_ <br />Q <br />fn <br />02-25-2020 O <br />Z <br />REVISIONS: < <br />No. Description Date C1 <br />w <br />Uj <br />w <br />I J <br />Q <br />U <br />W <br />O <br />AOOO Z <br />O <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.