- 11 1 ' - I -- I I I 11 1 1 11 11 'W I I "I I !q^! 1 I I II III I-J—f111 I, III II I I I I I I - -t I I I I I I ' II11111f ,I v I <br />— L <br />\\//\ a a <br />a <br />on <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />� V a <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />—� - <br />(MAX 20" <br />DEEP) <br />a _ <br />a d. <br />N <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL <br />VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*_BEARINGWRB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />— — — — — — — UJ <br />o <br />VAPOR BARRIER �\UJ <br />� o x <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />L <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM #5 . //�\ /\' #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. ri <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 U J (1) #4 OR #5 <br />WF OR FIBERMESH > ¢ Q U)CONT <br />W <br />o s LUUj <br />cn <br />— - — — - U W_ FINISH <br />4.> nt a. °- <br />O GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />i � I <br />_D <br />o <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL OR <br />#5 IN BRICK LEDGE <br />E <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CONCRETE SLAB W/ 6x6 <br />(1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH <br />MINIMUM 24" (1) #4 OR #5 90' BEND @ 48" O.C. <br />36" MAX VARIES PER — — — — — - -o a — <br />ARCH PLANS .\ ..\ .\ :\ ..\ <br />VAPOR BARRIER <br />IN d \ <br />/ FOOTING TO BEAR ON FIRM <br />/�/\ //\�// a• / UNDISTURBED SOIL <br />/\ �\\/%//% \ <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO. 4 OR NO. 5 (2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ <br />�-� (2) #5 OR (3) #4 CONTINUOUS <br />o1 A� MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />"NOTE": IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"1" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />U <br />W1.4 x W1.4 WWF OR d <br />FIBERMESH <br />_rn <br />— D SEE ARCH <br />(MAX 16") O <br />cy <br />C14 A 0 <br />0 <br />U? <br />VAPOR BARRIER \//\\�\\\/\\/� PEX <br />12" MIN /\/\\/\� 00 U <br />0 <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J +, <br />BAR IN BRICK LEDGE LI- <br />16" UNDER 2 STORY WALL w/ wtds <br />(2) #5 OR (3) #4 CONTINUOUS J <br />true design studios N <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLYWO PREVENT EROSION OF SOIL. G <br />CONCRETE SLAB w/ 6x6 LV <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH j <br />--a--�--- —� -- - a— --d -- — 011H09ON" <br />\/\\ 4 /\ mwi it <br />W <br />16" VAPOR BARRIER Q ±; <br />Z <br />0 <br />rn <br />3 BEARING WALL FOOTING SECTION v <br />Z <br />W <br />W <br />CONCRETE SLAB W/ 6x6 Of <br />W1.4 x W1.4 WWF OR c:) <br />FIBERMESH p <br />0'-0" A.F.F. <br />° SEE ARCH <br />a a \d DETAILS>= <br />I� <br />8" MIN Z ♦ ^ <br />W <br />8"x8" THICKENED 8" U) <br />FTG AT U) <br />STEP-DOWN, SEE VAPOR BARRIER W 7 <br />U) PLAN J Z LV <br />4 CURB STEP SECTION 00 Uj O U) <br />W QW <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL Z Q Q <br />6x6 W1.4 x W1.4 WWF Ui W p <br />LILI <br />OR FIBERMESH VARIES ° SEE ARCH Q Q J W <br />- ° a - <br />(MAX 16") � LL,I LLI <br />LL <br />12" MIN %\\/\\/\\/\\/\� Z <br />Z <br />VAPOR BARRIER <br />/ 6" OPT. EXTENSION IN BRICK I ­_LOCATIONS ON FND PLAN a Z_ <br />w <br />12" UNDER 1 STORY WALL w/ <br />W <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL. <br />BAR IN BRICK LEDGE — <br />16" UNDER 2 STORY WALL w/ Q LLI <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park J <br />O U <br />5 GARAGE EXT WALL CURB SECTION J U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 003-01-A p <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY _ <br />PER S-0" HORIZONTALLYWO PREVENT EROSION OF SOIL. w <br />O PROJECT NO: <br />CONCRETE SLAB W/ 6x6 -j 2019.007595 <br />O IL <br />W1.4 x W1.4 WWF OR <br />FIBERMESH Z DRAWN: -- 0 <br />0'-0"A.F.F' SEE ARCH U JMM o <br />--d — — a — (MAX 20" W 0 <br />\\ \\ \\ 4 a a a DEEP) X cHKD: EAF <br />r�\�� W W <br />4" EXTENSION X , � <br />UNDER BRICK VENEER ♦,�� �'(%N LAND ♦� <br />` I <br />12" UNDER 1 STORY WALL } �♦ J ••�G E N S c) <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m F Z <br />p o 851 <br />16" UNDER 2 STORY WALL LI-I * k Q <br />Z <br />BEARING CURB STEP SECTION •:• ST E OF 4tj u) <br />LLI <br />z' S ••....•• j <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />III _ <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />O 09-23-2019 p <br />�— W <br />cn <br />U_ REVISIONS: LU <br />U- <br />Q No. Description Dat� W <br />� � J <br />} U <br />U) <br />O I— <br />Z Z <br />= O <br />U p <br />W <br />X W ST=2mD <br />n <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />