1n <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />a ° - <br />---- -- a -----a- --d -- <br />\ \ \ ° <br />i i\yam\ <br />in <br />VAPOR BARRIER <br />3 * <br />BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />a <br />0'-0" A.F.F. SEE ARCH <br />(MAX 20" <br />° DEEP) <br />d a ° <br />a <br />EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL - VAPOR BARRIER <br />16" UNDER 2 STORY WALL I <br />BEARING CURB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />U) <br />Q O <br />VAPOR BARRIER �\\� � woLo <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />\\ t, L .- a \/X <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR <br />#5 . //�\ j #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Ilk <br />(BEYOND) <br />FLOATING CONCRETE w ! U-BLOCK W/ <br />SLAB W/ 6x6 Wl AxW1.4 U J (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q U) CONT <br />,. w w uJ <br />-, , • s -,. ;En cr � FINISH <br />//\//\///\/\ \ \ O GRADE <br />\\/\\//\\/, //\\//\//\ <br />Ox <br />#4 OR #5 VERT REINFORCING \\ % \%\\%\\%\ \\\/ <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. Y o o <br />i � I <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM 4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />(VTEMWALL CURB SECTION <br />SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CONCRETE SLAB W/ 6x6 <br />(1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH <br />MINIMUM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />VARIES PER <br />- - - - - - - <br />36" MAX <br />ARCH PLANS <br />a a\�/\\� <br />\/\\�\\ <br />///\N//\/// <br />12" MIN <br />�` <br />° VAPOR BARRIER <br />/�\//%//%\ <br />\\�//� <br />�' / UNDISTURBED OI FOOTING TO BEAR ON FIRM <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO. 4 OR NO. 5 (2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />rlA MONOLOTHIC FOOTING SECTION - 36" MDEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"1" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER S-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />0 <br />CONCRETE SLAB W; 6x6 - U <br />W1.4 x W1.4'AVJF OR o <br />FIBERMESH <br />E <br />SEE ARCH N O <br />l'7/-7 �,, T� 7/ - - (MAX 16") U <br />O O <br />/\ N <br />VAPOR BARRIER--/i���J <br />\�' o l% ' 12" MIN%\\/\\/\\/\\/\U')0 <br />//•� I �\/\ \ r\\j�\ \\ \\\\ \ N _c <br />U <br />/00(U <br />c:) <br />FOOTING TO BEAR ON ---- 6" OPT. EXTENSION IN BRICK O <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN ' (B <br />SOIL �- <br />12" UNDER 1 STORY WALL w/ N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 M <br />BAR IN BRICK LEDGE <br />J <br />16" UNDER 2 STORY WALL w/ LL <br />(2) #5 OR (3) #4 CONTINUOUS LLI <br />J tds J-6 r_MONOLITHI-C_FOOTING SECTION _ j trace design studios 4)4) <br />Ul CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z <br />FOLLOWING OCCUR: 0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />CONCRETE SLAB w/ 6x6 O O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR CO)FIBERMESH w <br />y ° <br />d Al DR&HOMON' <br />�-cs <br />co <br />16" VAPOR BARRIER U <br />Q <br />3 BEARING WALL FOOTING SECTION <br />U <br />U <br />Z <br />W <br />CONCRETE SLAB W/ 6x6 0 <br />W1.4 x W1.4 WWF OR W <br />FIBERMESH Q� <br />0'-0" A.F.F. C) <br />SEE ARCH O <br />a \ <br />DETAILS d? <br />8„ MIN <br />/ <br />b 0 <br />8'x8"THICKENED - I 8" ZFTG AT LV <br />STEP-DOWN, EE VAPOR BARRIER W <br />PLAN <br />r1\ Z <br />LL CURB STEP SECTION U)Z LV <br />DO <br />JU) <br />\ - w <br />- - - ---_-- w V <br />8" UNDER MASONRY WALL w <br />Z <br />Q <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL I O <br />6x6 W1.4 x W1.4 WWF Z > Q Q <br />OR FIBERMESH j SEE ARCH w 0 <br />_ --- VARIES Q LIJ Uj <br />�- -�- -- V-- - ` -- (MAX 16") <br />W_ a <br />>, ° a j �j/ 12' MIN j�\\ <br />LL <br />' \/�\/�/\//\ 0 Z <br />VAPOR BARRIER '%\\\ c -\\\ F.i \ / / : /, <br />O <br />6" OPT. EXTENSION IN BRICK 10 1 LOCATIONS ON FND PLAN O F_ <br />12" UNDER 1 STORY WALL w/ 1 D' Z <br />(2) #5 OR (2) #4 CONTINUOUS — ADDITIONAL NO. 4 OR NO. 5 <br />---- BAR IN BRICK LEDGE 0 a <br />16" UNDER 2 STORY WALL w/ ILL <br />(2) #5 OR (3) #4 CONTINUOUS <br />GARAGE EXT WALL CURB SECTION Abbott Park Q <br />5 _ O U <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE -j U) <br />LL <br />FOLLOWING OCCUR: Q LOT 003-02-A p <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28"LLI <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY ~ <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Z Z <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. - 0 <br />>- cl) <br />CONCRETE SLAB W/ 6x6 O PROJECT NO: LU <br />.4 W W1.4 x W11NF OR J 2020.001721 0 <br />FIBERMESH 1 ILL0'-0" A.F.F. 0 <br />- --- -- -- ---a - ----- - -- SEE ARCH Z DRAWN: <br />-� - -- -- -- - - - 20„ <br />(MAX U KG o <br />` <br />a I - DEEP) <br />° I �_—a O <br />CHKD <br />EAF to <br />4" EXTENSION <br />J <br />UNDER BRICK VENEER X U <br />4 tttttt��� <br />12" UNDER 1 STORY WALL j ��SIN LqN <br />w/ (2) #4 OR (2) #5 CONT �� VAPOR BARRIER } ��� , �F,9 <br />m �• �E N S ' .� Z <br />16" UNDER 2 STORY WALL •• O 85 66 ••• > <br />W/ (3) #4 OR (2) #5 CONT I W <br />i <br />6'BEARING CURB STEP SECTION :-o <br />/ % S ATE OF .' 4t/Z ' <br />i <br />TYPICAL REINFORCI <br />% BARS AT THICKENE <br />FOOTING, SEE PLAN <br />l <br />r MIN 24" LONG #4 O <br />BAR SET AT MID -DE <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORN <br />HOUSE_SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />R <br />• (A <br />0 <br />NG 1 Z is O N A%E %0 <br />D <br />O 02-25-2020 <br />#5 w <br />PTH i co <br />U REVISIONS: w <br />ERs Q No. Description Date W <br />----i � <br />-� Q <br />0 � <br />O ~O <br />- J O z <br />m Q <br />U <br />w <br />X <br />W ST 2D <br />W <br />CMU/METAL CONNECTOR ENGINEERING <br />■� <br />