Laserfiche WebLink
TRUSS TO TOP PLATE <br />W/ H2.5T OR R77AT <br />OR SDWC15600, UNO MOISTURE BARRIER-------/ <br />ON PLAN BETWEEN MASONRY AND <br />NON -PT LUMBER BY OTHERS <br />VERT. REINFORCING TO <br />HAVE 10" STANDARD <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 , <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />�7►6_nh1a&_Aff <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR <br />HTA16-18 W/ MIN (7) 10d x 1'/z" <br />IN TRUSS (NOTE: IF META12 <br />OR HTA16-18 IS IMPROPERLY <br />INSTALLED, ATTACH TRUSS <br />TO BOND BEAM W/ HTSM20 <br />OR HTWM20) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1 <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM <br />PLATE W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />%" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2' WEDGE BOLT W/ MIN 4Y2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />'EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 25" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />MOISTI <br />BARRIE <br />OTHER <br />(1) COl <br />CMU B <br />BEAM <br />CONTII <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN tV12' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x <br />1%" IN TRUSS (NOTE: IF META12 OR <br />HTA16-18 IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND BEAM W/ <br />HTSM20 OR HTWM20) <br />FOR MISLOCATIO <br />FASTEN 2x6 NO.2 <br />TO TRUSS W/ MIN I <br />FOR MISLOCATIO <br />INSTALL NEW MAC <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />T FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />(1)#f <br />CORNERS <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4" OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/ <br />3%4" <br />37/16 <br />5" <br />115/ 6 <br />33/4 , <br />3 3/4"6„ <br />---- 2 �4, <br />33/4 <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS '/<" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/ti' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1 x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />V <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED W) <br />— 1x_ PT NAILER <br />BUILT UP 2X_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />U <br />O <br />O <br />N <br />} <br />a <br />O <br />APEXco <br />s <br />4 <br />O <br />N <br />rn <br />a <br />ca <br />0 <br />N <br />zzz <br />co <br />J <br />6 <br />U_ <br />W <br />tds <br />i= <br />-6 <br />J <br />J <br />� <br />true design studios <br />O <br />U) <br />U <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />vy <br />O <br />O411 <br />_o <br />W <br />nwxwmuwxnm <br />C <br />011HOMON' <br />0) <br />o <br />w <br />W' <br />Q <br />0 <br />L7 <br />U <br />z <br />W <br />0 <br />w <br />w <br />O <br />O <br />O <br />O <br />ti z <br />ti <br />p w <br />Z w <br />U) M� W_ <br />W Um <br />W <br />Z <br />U) Z W <br />.1 0 U) <br />m <br />w <br />w <br />w <br />Z Q O <br />(D <br />z <br />o W L.LI <br />V _w/ <br />O W 0. <br />J LL <br />ILL <br />z <br />O <br />O <br />a <br />O <br />U <br />Q <br />Abbott Park <br />O <br />J <br />ILL. LOT 003-02-A <br />U <br />z <br />OPROJECT NO. <br />O 2020.001721 <br />DRAWN: <br />U KG <br />W CHKD: <br />~ EAF <br />X <br />w <br />IZ <br />Q <br />LA/V�� <br />w o 51 6 <br />• <br />Z <br />��� :X= <br />O %� ' ST E OF : 44/ <br />W <br />Rl <br />Z <br />O 02-25-2020 <br />H <br />v REVISIONS: <br />U_ <br />Q No. Description Date <br />C� <br />O <br />J <br />O <br />Z <br />U <br />w <br />F- <br />X <br />w ST=5 <br />a <br />2 1 <br />0 <br />ti <br />X <br />z <br />O <br />0 <br />z <br />LL <br />w <br />J <br />U <br />U) <br />0 <br />w <br />F- <br />a <br />z <br />0 <br />co <br />w <br />0 <br />ILL <br />O <br />0 <br />O <br />L0 <br />U) <br />w <br />J <br />Q <br />U <br />U) <br />CD <br />z <br />U) <br />Z <br />0 <br />w <br />U) <br />w <br />w <br />_I <br />a <br />U <br />U) <br />F- <br />O <br />z <br />O <br />0 <br />■! <br />E� <br />CMU/METAL CONNECTOR ENGINEERING <br />