My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8132 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8132 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:38:40 AM
Creation date
2/27/2025 1:17:36 PM
Metadata
Fields
Template:
Building Plans
Street #
8132
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
357
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />� ° d <br />° - <br />-\\ <br />/x`/ <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0"A.F.F. SEE ARCH <br />(MAX 20" <br />DEEP) <br />d /x/ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*gEARING CURB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB <br />BLOCK W/ (1) #4 OR #5 CONT. <br />— — — — — — <br />— <br />Q <br />LU <br />Q o <br />VAPOR BARRIER - //\\\/ <br />w <br />� <br />0 <br />o <br />#4 OR #5 VERT REINFORCING / <br />UP TO 3 COURSES: 72" O.C. <br />//\\//\// <br />X <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM\/ <br />ADDITIONAL #4 OR <br />//�\ �' <br />#5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT <br />4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 )STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, <br />PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS <br />CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 U U) (1) #4 OR #5 <br />WWF OR FIBERMESH > e Q ~ cn w CONT <br />0 FINISH <br />O GRADE <br />LO <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. p o o <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL OR <br />#5 IN BRICK LEDGE <br />E <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />1 #4 OR #5 CONT. CONCRETE SLAB W/ 6x6 <br />() W1.4 x W1.4 WWF OR FIBERMESH <br />MINIMUM 24" (1) #4 OR #5 90' BEND @ 48" O.C. <br />VARIES PER <br />36" MAX <br />ARCH PLANS <br />° d ° /\ 1 / <br />/ / \\ / /` ° \ <br />r \12" MIN VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO. 4 OR NO. 5 (2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />(ol A1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />"NOTE": IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"1" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB Wi 6x6 <br />W1AxW1.4WWFOR <br />FIBERMESH <br />c �\ <br />VAPOR BARRIER <br />U <br />0 <br />> E <br />O <br />SEE ARCH C3 <br />(MAX 16")O <br />_ o <br />— - N I O <br />04 <br />N <br />cl <br />FOOTING TO BEAR ON <br />FIRM UNDISTURBED OPT. EXTENSION IN BRICK L SOIL LOCATIONS ON FND PLAN N <br />N <br />12" UNDER 1 STORY WALL wi M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE U_ <br />16" UNDER 2 STORY WALL wi Ic <br />(2) #5 OR (3) #4 CONTINUOUS W <br />J tds J-6 <br />true design studios <br />MONOLITHIC FOOTING SECTION z <br />1CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 Vi <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER S-0" HORIZONTALLWO PREVENT EROSION OF SOIL. 00 <br />CONCRETE SLAB w/ 6x6 w cy <br />c <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR w <br />FIBERMESH j 0 <br />--- ---- - - -- -_ - - s— --�co sHOMON' <br />16" ) VAPOR BARRIER Q <br />0 <br />U) <br />3 BEARING WALL FOOTING SECTION U <br />z <br />w <br />0 <br />w <br />CONCRETE SLAB W/ 6x6 -� x <br />W1.4 x W1.4 WWF OR <br />FIBERMESH o <br />-- - 0' 0" A.F.F. cy) <br />SEE ARCH <br />DETAILS �} <br />d <br />° <br />8" MIN <br />o Cn <br />z LLI <br />8"x8" THICKENED 8" W W W <br />FTG ATI VAPOR BARRIER L.L <br />STEP-DOWN, SEE � <br />PLAN_ <br />�4 CURB STEP SECTION m Uj O w <br />w <br />8" UNDER MASONRY WALL Z_ <br />- 1 6UNDER WOOD WALL 5 > O Q <br />CONCRETE SLAB W/�-`--� " � IZ � � Q Q <br />6x6 W1.4 x W1.4 WWI` <br />OR FIBERMESH - --_--_- - VARIES Q w <br />SEE ARCH Q <br />G LL X <br />- -- _ <br />LLLL <br />/\/ Z< z <br />• / / \\/� \/\\/\\\��\/%\//�\/�\\//\\ 0 O <br />LU <br />6" OPT. EXTENSION IN BRICK O E- <br />_I 1 LOCATIONS ON FND PLAN a z <br />1-._..- ADDITIONAL NO. 4 OR NO. 5 U <br />BAR IN BRICK LEDGE <br />Q W <br />� Abbott Park JQ <br />5 GARAGE_ E__XT WALL CURB SECTION U) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE w LOT 004-02-A 0 <br />FOLLOWING OCCUR: Q Fw- <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ Z <br />FROM STRUCTURE STEEPER THAN 1'4' VERTICALLY _0 <br />PER 3-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. (n <br />O PROJECT NO: W <br />CONCRETE SLAB W/ 6x6 J 2020.001722 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH Z DRAWN: O <br />-----_ - - A.F.F_ SEE ARCH U KG o <br />(MAX 20„ <br />° d ° ° a DEEP) CHKD: U) <br />X EAF <br />W W <br />4" EXTENSION X U <br />UNDER BRICK VENEER <��`''iN' Lq ���,�♦ <br />------------ ,, <br />12" UNDER 1 STORY WALL ••••N •� ♦ 0 <br />Z <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m `� •'�,\�� E N S'� ♦�♦' <br />' Q i <br />i <br />16" UNDER 2 STORY WALL Z * NO $5 66 <br />w/ (3) #4 OR (2) #5 CONT <br />6BEARING -CURB STEP_ SECTION �:,. S ATE OF ••:� U) <br />/ <br />Q ♦♦ �cs • O R , • • C? ��` z <br />TYPICAL REINFORCING <br />i BARS AT THICKENED Q 02-25-2020 <br />FOOTING, SEE PLAN <br />F_ w <br />j -- MIN 24" LONG #4 OR #5 U REVISIONS: <br />BAR SET AT MID -DEPTH _ <br />OF SLAB, TYP ALL U_ I— <br />j No. Description Date <br />RE-ENTRANT CORNERS Q W <br />�I -— — — — ---- (A J <br />HOUSE SLAB 0 <br />O <br />i <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />VAPOR BARRIER <br />z O <br />2 � <br />U <br />w <br />I— <br />x W ST=2mD <br />d <br />CMU/METAL CONNECTOR ENGINEERINGa <br />
The URL can be used to link to this page
Your browser does not support the video tag.