My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8160 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8160 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:18:31 PM
Creation date
2/27/2025 1:18:03 PM
Metadata
Fields
Template:
Building Plans
Street #
8160
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
456
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:�ocusign envelope ID. BA90027F-306F-48B1-A537-1FF164EA6312 <br />4 ° <br />4 ° <br />16" <br />n <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° 4 <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4xW1.4VVWFOR <br />FIBERMESH <br />° 4 <br />12" UNDER 1 STORY WALL <br />16" UNDER 2 STORY WALL <br />0'-0" A.F.F. SEE ARCH <br />(MAX 20" <br />DEEP) <br />4 <br />- 4„ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />VAPOR BARRIER <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />TOP OF SLAB <br />r b77- �rr -cam r - <br />Lu <br />/\\\%\\\/\ j Q o <br />VAPOR BARRIER/\\/ LLJ w wo <br />/ <br />cn <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. x <br />t� <br />L e V <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />AEIVA2a <br />(BEYOND) <br />FLOATING CONCRETE w_ <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES' 48" O C <br />- U-BLOCK W/ <br />U J (1)#4OR#5 <br />a w CONT <br />n y W W uJ w <br />J w FINISH <br />0 GRADE <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CONCRETE SLAB W/ 6x6 <br />(1) #4 OR #5 CONT. <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIMUM 24" (1) #4 OR #5 90' BEND @ 48" O.C. <br />36" MAX VARIES PER <br />ARCH PLANS <br />a as <br />a 4 4A <br />7/ <br />\12" <br />MIN <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS -- <br />ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO.4 OR NO. 5 <br />(2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE <br />- <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />1 <br />MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"1" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK <br />GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />U <br />0 <br />co <br />�. SEE ARCH N \ O <br />(MAX 16") U <br />\/ p <br />Z.MIN/\ PEX <br />-C <br />• �/� '\\r\\i\\ \\ \\ \\ \\ c� c� <br />•Yi r.//i.// /// 00 N <br />�a) <br />FOOTING TO BEAR ON r / 0 N <br />FIRM UNDISTURBED 6" OPT. EXTENSION IN BRICK <br />SOIL LOCATIONS ON FND PLAN <br />12" UNDER 1 STORY WALL w/ N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />BAR IN BRICK LEDGE J <br />16" UNDER 2 STORY WALL w/ LL <br />(2) #5 OR (3) #4 CONTINUOUS LLI <br />J tds <br />(PFOONOLITHIC FOOTING SECTION true design studios DONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z <br />LLOWING OCCUR: Q <br />*OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" CA <br />. GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />ch <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. O <br />t3 <br />CONCRETE SLAB w/ 6x6 O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR � <br />FIBERMESH W <br />~ CD <br />° 4 ° a 4 <br />4 >\ UsHOMON' <br />m <br />/ 16" VAPOR BARRIER Lu ZZ: <br />C� <br />3 BEARING WALL FOOTING SECTION } <br />z <br />W <br />CONCRETE SLAB W/ 6x6 (D <br />W1.4 x W1.4 WWF OR W <br />FIBERMESH 0f <br />0'-0" A.F.F. 0 <br />4 - SEE ARCH p <br />\ a \4 ° 1 DETAILS <br />\�\//�. \ 4 --- -' <br />8" MIN LO <br />° /. <br />a O O <br />8"x8" THICKENED 8" Z U) w <br />FTG AT <br />STEP-DOWN, EE VAPOR BARRIER co V J ��/ <br />PLAN W W ly <br />CURB STEP 4 z um <br />SECTION U Z LV <br />m O � <br />J _ <br />8" UNDER MASONRY WALL W G <br />W <br />z QCONCRETE SLAB W/ 6" UNDER WOOD O WALL _ i � <br />6x6 W1.4 x W1.4 WWF Q <br />OR FIBERMESH VARIES 4 SEE ARCH W <br />-- - -- (MAX 16") Q W W uj <br />- - _ o _!LLJ <br />/ w <br />4 \/ 12" MIN\�/\\/\��\\/\� J <br />\\ ° � j r \\ \\\/\//\\\ z <br />VAPOR BARRIER \// ° 4 Z <br />r;\ \ �. O <br />\ / 6" OPT. EXTENSION IN BRICK < 0 <br />LOCATIONS ON FND PLAN <br />12" UNDER 1 STORY WALL w/ d Z <br />(2) #5 OR (2) #4 CONTINUOUS j ADDITIONAL NO. 4 OR NO. 5 <br />_ BAR IN BRICK LEDGE 0 a <br />16" UNDER 2 STORY WALL w! LL <br />(2) #5 OR (3) #4 CONTINUOUS <br />—� Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION <br />O U <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE -� - - (A <br />FOLLOWING OCCUR: LOT 008-02 Q <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" Q - - - - w <br />. GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY V Q <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Z Z <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. - (D <br />} U) <br />CONCRETE SLAB W/ 6x6 PROJECT NO: w <br />W1.4 x W1.4 WWF OR 0 0 <br />FIBERMESH Q 2020.004112 LL <br />0'-0" A.F.F. SEE ARCH Z - - _ O <br />---- --- - DRAWN: <br />—4 - - - -- - - -(MAX 20" <br />r \ \ a 4 — DEEP) ° 4° ° 4 ° 4 ' I=UI I KG <br />LO <br />d — CHKD: <br />w EAF W <br />4" EXTENSION <br />UNDER BRICK VENEER X ,`tttt���B �nR���I,U <br />� . � . U� <br />12" UNDER 1 STORY WALL ,��� �{", S 9 ���,cn <br />VAPOR BARRIER ��: ��. •'•E N ••�.' <br />w/ (2) #4 OR (2) #5 CONT } <br />om Po kgn&jd IYU: z <br />16" UNDER 2 STORY WALL Qft <br />w/ (3) #4 OR (2) #5 CONT Z- Q <br />-- - <br />BEARING CURB STEP SECTION ;,� s`raT of .•� o <br />OW .,� '�4437.rn <br />TYPICAL REINFORCING Z <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />O 06/02/2020 p <br />MIN 24" LONG #4 OR #5 �_ W <br />\ I BAR SET AT MID -DEPTH I- (n <br />OF SLAB, TYP ALL U_ REVISIONS: <br />RE-ENTRANT CORNERS LL - m <br />Q No. Description Date <br />I� -- ---- - - w <br />- -- - -- -- -- U' <br />- -- G7 <br />HOUSE SLAB O - - - Q <br />— -- - Z -- —.! Z <br />RE-ENTRANT CORNER DETAIL = O <br />(RECOMMENDED) w <br />PLAN VIEW, DETAIL TYPICAL @ ALL I— <br />RE -ENTRANT CORNERS X <br />W ST=2D <br />CMU/METAL CONNECTOR ENGINEERING¢ <br />CONCRETE SLAB W/ 64 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />/ <br />VAPOR BARRIER <br />
The URL can be used to link to this page
Your browser does not support the video tag.