Laserfiche WebLink
1 _ <br />DocuSign Envelope ID: 5249DB1B-6FC9-4BE9-9C1C-72AA2579EC�2 <br />DESIGN CRITERIA AND LOADS <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />NOTES 2, 3, 4 <br />N <br />Buildinq Code <br />Florida Building and Residential Codes 6` Edlt,on i2'i' <br />Code for Design Loads <br />ANSI/ASCE 7 <br />ROOF LOADING'..... ..... <br />TOP CHORD LIVE LOAD <br />TOP CHORD DEAD LOAD <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE: <br />ATTICS WITHOUT STORAGE <br />BOTTOM CHORD DEAD LOAD <br />WIND LOADING .......... _ <br />ASCE 7-10, 3S GUST <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY - <br />BUILDING CATEGORY... ... <br />ENCLOSURE CLASSIFICATION <br />INTERNAL PRESSURE COEFF. <br />C&C DESIGN PRESSURES.. _ <br />FLOOR LOADING.... ..... _. . . <br />TOP CHORD LIVE LOAD - <br />TOP CHORD DEAD LOAD..... <br />BOTTOM CHORD LIVE LOAD... <br />BOTTOM CHORD DEAD LOAD. <br />1 2� <br />-? PSF <br />PSF .i, <br />PSF <br />PSF <br />NON-C <br />PSF <br />= 1 6G <br />MPH <br />ENCLOSE[ <br />0 18 <br />(SEE TABL I <br />C,, <br />40 PSF <br />10 PSF <br />0 PSF <br />5 PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING <br />C, - 1 _uJ <br />TOP CHORD LIVE LOAD..... <br />60 PSF <br />TOP CHORD DEAD LOAD.... <br />10 PSF <br />BOTTOM CHORD LIVE LOAD. <br />0 PSF <br />BOTTOM CHORD DEAD LOAD <br />5 PSF <br />MAXIMUM FLOOR TRUSS SPACING <br />1r" c� <br />DEFLECTION CRITERIA <br />ROOF TRUSSES ................... <br />TL ' 8C <br />_L MAX 1 <br />LL1480 <br />TL i 360 <br />OPEN WEB FLOOR TRUSSES <br />LL 480 <br />TL 240 <br />WOOD I JOISTS..... _.._... - _ <br />TL MAX ' <br />LL ' 360 <br />BEAMS. ............................_- - <br />TL ' 240 <br />NOTES: <br />1. PORCH BEAMS AND BEAMS SUPP ''TIN <br />[_ xT[Rl;;t. <br />ABOVE SHALL NOT EXCEED /. DE_ I ECTI <br />_)tv <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURE <br />WINDOWS AND DOORS <br />EFFECTIVE T )NE DESIGNATION <br />WIND AREA IZ - Intent [ t I:n: <br />0 - 20 ft2 +28 54 :S0 96 1 +28 54 <br />21 - 50 ft2 +27 17 29 59 +27 17 <br />51 - 100 ft2 +25 52 9c -25 5 <br />101 - 200 ft2 +24.25 t; 6; +24 2' - <br />VINYL SOFFIT MAX PRESSURE tpsf +28 I_ <br />GARAGE DOOR PRESSURE +21 <br />END ZONE KEY MAP <br />END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1ST 4.0' PER FIGURE R301 2 (7, <br />Ii <br />1STFIAOR <br />4.0 FT <br />(TYP) <br />� END l <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />^.c )TFS 3 4 <br />U' <br />STUCCO AND DIRECTLY <br />MIN'%32" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (%,"24/16 <br />w = <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.0 IN THE <br />^ <br />� I- N <br />Q <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />w� <br />0 <br />Z <br />ALL OTHER VENEER <br />MIN %6 " 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />�Q <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES), <br />6" O.C. AT PANEL EDGES, 12" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />TILE ROOF <br />MIN'Y32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />Y c� <br />z <br />(NOTE 7) <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 4" O.0 AT PANEL EDGES AND <br />u <br />Uj <br />8" O.C. IN THE FIELD <br />LL Q O <br />0 w z <br />SHINGLE AND METAL ROOF <br />/5 MIN 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED VVITH LONG DIMENSION <br />0 T_ <br />(NOTE 9) <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS 6" O.C. AT PANEL EDGES, 12" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />23/32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN Y8' OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />ORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN %2" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 •/" COOLER NAIL OR NO.6 x 1 %4" LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES <br />FOR SHEATHING THICKNESS GREATER THAN 1%2" CATEGORY (32/16 SPAN RATING), USE 10d RING SHANK NAILS IN LIEU OF 8d RING <br />SHANK NAILS. (0.148" x 3" LONG). <br />COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />= ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS. <br />FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO HELP <br />REDUCE SQUEAKING, 8d RING SHANK NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />'V32" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />C BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD. SHOULD BUILDER SPECIFICATIONS ALLOW MIN <br />STRUCTURAL REQUIREMENTS ARE 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />%2' PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW. t%2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />MINIMUM STRUCTURAL ROOF SHEATHING REQUIREMENTS FOR METAL ROOF CLADDING IS SAME AS SHINGLE ROOF. SHOULD ROOF <br />MANUFACTURER'S INSTALLATION DRAWINGS REQUIRE SPECIFIC ROOF SHEATHING EXCEEDING THE STRUCTURAL MINIMUM, <br />CONTRACTOR SHALL PROVIDE ROOF SHEATHING IN ACCORDANCE WITH ROOFING SPECIFICATIONS. <br />TABLE 4: NAIL SIZE LEGEND <br />NOTES 1, 2, 3, 4 <br />DIAMETER <br />LENGTH <br />8d COMMON <br />0,131" <br />2-1,!" <br />8d RINGSHANK <br />0.113" <br />2 %" <br />10d x 1-'Yz" <br />0.148" <br />1-1/2" <br />10d <br />0.131" <br />3" <br />1 10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3-'/4" <br />16d SINKER <br />0.148" <br />3-Y4" <br />16d COMMON <br />0.162" <br />3-Y2" <br />TABLE 5: FASTENERS IN <br />PRESSURE TREATED LUMBER <br />IV PRESERVATE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />STAINLESS CONNECTORS AND <br />SODIUM BORATE (NOTE 1) <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />Z-MAX, G120 OR TRIPLE ZINC <br />ALL OTHER PT <br />COATED FINISH. <br />(INCLUDING ACQ & MCQ) <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />NOTES: <br />2 COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />1 SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE <br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. <br />4 THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2.500 PSI Al- 28 DAYS (UNO). <br />2 CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). <br />3 ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO) <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5 FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF FIBER LENGTHS SHALL BE '/2' TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6 MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7 EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf IN <br />ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8 CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH APPROVED CHEMICAL SOIL TREATMENT FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9 STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10 TO CONTROL CRACKING, CUT V SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />y' WITH CONCRETE WORK. <br />11 DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION. SPAN DIRECTION, SPACING. BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />4 TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />5 I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION SEE DESIGN CRITERIA, <br />THIS SHEET. <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />MITEK <br />USP FASTENERS <br />SIMPSON <br />SIMPSON <br />MITEK <br />USP FASTENERS <br />FASTENERS <br />(8)'/4 X 1 YP SDS SCREWS <br />DTT2Z <br />IN STUD /2" 0 X 4 /2 <br />WOOD SCREWS INSTUD <br />9 10d COMMON <br />(9) 10d <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />'/2 0 x 4'/2" EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />EACH END <br />----- <br />(18)0.162"x2'/2"IN <br />(18)0.162"x2 Y2"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MTS12 <br />(7) 10d x 1 Y2" <br />MTW12 <br />(7 1) 1od x 1 <br />(NOTE 2) <br />46" 0 x 6" EMBED ANCHOR <br />4a" 0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 Y2" IN <br />(26) 0.162" x 2 Y2" IN <br />HTTS <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MSTA24 <br />(9) 10d COMMON <br />MSTA24 <br />(9) 10d COMMON <br />(NOTE 2) <br />46" 0 x 6" EMBED ANCHOR <br />�6„ O x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(20)Y4' x 3" SDS SCREWS <br />(24) 3" WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP 7 " 0 x 12" EMBED <br />a <br />MSTA36 <br />(13) 10d COMMON <br />MSTA36 <br />(13) 10d CCMM'_)N <br />7/$" O x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />( <br />10d COMMOI I N <br />(7) , <br />„ <br />(7) 10d x 1 /2 IN TRUSS <br />(7) 10d x 1 /2 IN TRUSS <br />META12 <br />4" WET EMBED IN <br />HTA16 18 <br />4" WET EMBED IN <br />MSTAM36 <br />WOOD FRAMING <br />MSTAM36 <br />WOOD FRAMING <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(4) 'Y," x 2 ''/4" TITEN <br />(5) %' x 2 i3' TAPCON IN <br />SCREWS IN MASONRY <br />(11) 10d x 1 '/2" IN <br />MASONRY <br />(11) 10d x 1 Y.. IN <br />(8) 10d x 1 Y2" IN TRUSS <br />(9) 10d x 1 '/2" IN TRUSS <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(11) 10d x 1 1/2" IN <br />(11) 10d x 1 '!" IN <br />STUD <br />(12) 10d x 1 '/2" IN <br />STUD__ _ <br />(8) 10d x 1'/2" IN <br />ABU44 <br />(12) 16d COMMON NAILS <br />„ „ <br />U44 <br />(12) 16d COMMON NAILS <br />HTSM20 <br />TRUSS/RAFTER <br />HTWM20 <br />TRUSS/RAFTERPA <br />(NOTE 6) <br />48 O x 7 EMBED EPDXY <br />48 0 x 7 EMBED EPDXY <br />(12) 10d x 1 '/2" IN <br />�: � <br />(4) Y4 x 3 WEDGE 80L- <br />STUD <br />(5)8dx1Yz"IN <br />OR EQUIVALENT IN S T UG+'i <br />- <br />(5)8dx11/2"I^d <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />I' A BU66 <br />4"0x7"EM BED EPDXY <br />6 <br />PAU66 <br />4 " x 7" EMBED EPDXY <br />6 !Zj O <br />H2.5T/ <br />T <br />TRUSS <br />RT7/ <br />1 <br />TRUSS <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />(12" EMBED AT GARAGE <br />HA8 <br />(5) 8d x 11/2" IN <br />RT7AT <br />(5) 8d x 1 <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />(5) 10d x 11/2" IN <br />TOP PLATE <br />(5) 10d x 1'h" IN <br />HU48, <br />(14) 16d COMMON IN <br />HD48, <br />(14) 16d COMMON IN <br />HUC48, <br />HEADER <br />HD481F, <br />HEADER <br />H8 <br />TRUSS <br />RTBA <br />TRUSS <br />HU28-2, <br />HUC28-2 <br />(6) 10d COMMON IN BEAM <br />HD28-2, <br />HD28-21F <br />(6) 101 COMMON IN BEAM <br />(5) 10d x 1" IN <br />(5) 10d x 1 r IN <br />TOP PLATE <br />TOP PLATE <br />(16) 10d COMMON TO <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />LGT2 <br />(7) 'W" x 2 Y4' TITEN <br />G 2 <br />(5) 0" x 3" WEDGE BOLT <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />(26) 16d SINKER <br />OR EQUIVALENT <br />- <br />(28) 16d SINKER IN WALL <br />HUC212-2 <br />(22) 16d COMMON IN <br />HEADER <br />HD212-21F <br />(22) 16d COMMON IN <br />HEADER <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />LGT3 <br />IN WALL FRAMING <br />(12) SDS '/4" x 2 Y2" <br />LUGT3 <br />FRAMING <br />(12) WS25 %° x i <br />(4)%" x 1 '/2" SDS SCREW <br />(4)'/4" x 1'/z" WS15 SCREWS <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGA10KT <br />(4)%" x 3" SDS SCREWS <br />HGA10 <br />(4) ''/4" x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, <br />SDWC15600 <br />NO <br />USP EQUIV,ALEtN-F <br />(4) SDSY4" x 1 '/2' SCREWS <br />(4)'/4' x 1'/2" WS15 SCREWS <br />HGAM10KT <br />IN TRUSS/RAFTER <br />HGAM10KT <br />Y4 TRUSS/ RAFTER <br />(4) /4 x 1 /4 WEDGE BOLT <br />(4)'/4" x 2/4" TITEN SCREWS <br />IN MASONRY <br />OR EQUIVALENT IN <br />MASONRY <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALT"IEP.NF- ! ;-z <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2'/2" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />''/4" 0 x 2 3/4" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF %" 0 x 1 3/" TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL. <br />BED. <br />2. ENGINEER OF RECORD RECOMMENDS, BUT DOES NOT REQUIRE, ALL RUNNING BOND MASONRY WALLS TO BE EQUIPPED w/ 9 <br />GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT AT EVERY OTHER COURSE. <br />3. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />4. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 2,500 PSI. <br />5. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />6. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 25". <br />7. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING. <br />8. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />9. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />AM\ <br />O <br />I t: <br />O Q <br />1 <br />04 0 <br />APEX <br />,IT N U <br />00 N <br />ENGINEERED JEERED LUMBER, /4 WIDE, UNO. <br />it ! L LSi. BEAMS ARE EQUIVALENT TO 2-PLY 1 3/4" BEAM) 1 M <br />?_•F Pt ;! , MIL JL ENGINEERED LUMBER 1 3/4" WIDE <br />_ ,,! ! . R_ D L.JP., B R O/IDE. ONO. N <br />PR L I -)r—E_ ) ,NEB HEADER N <br />IN FERIOI . P JOF i_0AD BARING WALL, SPECIFICATIONS LL <br />! OUTLINI'_: WALL SECTIONS, DETAIL SHEETS L1�tds -6 <br />-� <br />. !N'TE 1 L��i" +' l AJa H id0 L1Pi_Ii=T. NO UPLIFT ANCHORS REQUIRED. MINIMUM J <br />J Bnr rr _. ., _ °dCFiOR ^, O.0 (U^. `,J ; RAMING PLAP! OR true design studios > . <br />z <br />_ O <br />Y 9000 REGENCY SQUARE BLVD. v <br />37 <br />--- - - -" Q SUITE 100, JACKSONVILLE, FL 32211 C6 <br />TlNi; TI V Plfi!C iOSiUL,J. —,j 0 <br />C <br />- - - ---- <br />Nt1 STUDS + <br />T <br />-1 <br />F 4,ND GRADF !!NO <br />W 1 <br />- -- hiD.JI + . ._. � .. ai � ii','v ��F if -'IF j-, i t; i' j! ' JR I <br />c :D t13 <br />cofifff"UMON <br />zi <br />t;.;: <br />v <br />N <br />DDOV'/N PEOUIRED AT BASE OF COLUMN I <br />lt•IU, n : -)I :t-,I Ni `-,`4APPING REQUIRED FROP.4 2ND LEVEL .>_I <br />_ '-- 37UIDS'HE.ADER/BEAM 00VIVO <br />-r�::< n- L„ <br />STUD f I' <br />�I � _ A 1 •�• b �F S :D COLUMN LLJS <br />--- - -- --- ONNIF T' f, ST E, h� E <br />,._C . INS, ;�.5 TO BOTTO 4+ PL T- <br />---_ . -- Nl ..: + �, _)F F :' i�� . !"yQ HEADER FO.J.t�CK TUD <br />n� - - ,YF'; O� I �A.t' `�,� vECrING HEADER C, TIl i - <br />-- — JACKS L U <br />z <br />r. <br />- i KI J.,. ",r N vE i ION W <br />r,-)L,)[.CIVJN REQt11REP BASE OF STUD GROUP 0 <br />[ 1PP'•iVG R=: Ui[?:. ,FROM 2ND LE'✓EI_ S I UD w <br />GP , l : t S HEADER;BFAM. <br />- --- - NUfv'!b L i i<,,1Ps AT BASE OF K;NG/ JACK GROUP <br />O <br />NCt•:= - I-----<._7i�iir:v KEYNO'_E 0') <br />SIDE OF OPENINGi <br />AS NC)"v BEARING HEADER DUE TO LIGHTLY <br />O <br />#2 SYF I {---JA . h.A' h K (NOTE w <br />— -- — NUI'',GcR )[= r N1' , ? _)2:S EACH SIDE OF OPENING U)Q + ) N <br />--- W 0J <br />���'_„ .SIDE. OF OPE!Jlr`Jv z 7 <br />W <br />uj <br />O u� <br />-- --- -- NU�rt EN ;( I c C„DL_ m <br />-, FNGiN [ _ + i _ I- Li -ADEP FRAMING KEYNOTE w <br />- _ _ Ch S:__ ._ OF PciNIN" z Q O <br />Ntla;,i(� EAC SIDE OF OPENING Z > Q <br />-i _,:'_ --SL OR, SYS4''1 W W 0 <br />_j W <br />bVDE UNO) — W Uj <br />LL <br />m LL <br />TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. z <br />O z: <br />r tiD G CONDITIONS 49' OR LESS CLEAR -OPENINGS IN AN 0 . <br />-:EADE_R . SEE PLAN. Q r <br />u _ .VNI 7i i "2) ROWS 1 % ;C 8 O.C.; S T AGGERED ALONG EACH EDGE. w <br />., raF it-K N... JYC C',iE"ILL+ _ "! + �.:t +tdL .=i� OI' I'l cl�O Rl�'. 1..L z <br />i , Kif.IG S I UD AND ( i SDVVC15450 KING STUD TO BOTTOM PLATE <br />r P�`+'•!''O CONNECTION REOUIRED FOR OPENINGS AT FIRS? O a <br />`' =tN, L :.;. S`IS L.i:1 IS ABO' E. U LL <br />i LL 3. f-I'` FOL;- ,`,dli�-'Fy,'� ' r' `� Q <br />t` NECTION REQUIRED FOR <br />WHEN' ! ND t.E� r_L F LO01, SYS E t,1 iS ABOVE. w . <br />J , <br />E SE:.'TICN IHE;'.DLRS) S!-Abbott Park S � �Q1 <br />``- LOT 011-02 0 <br />• _ ! J.>5 RL . ? HTS .vl (1Z, 11,J x: ,-i ' (OR EQUAL APPROVED BY FOR). Q W <br />CK BELOW NGPEADERS MAY BE FRAMED .AT 24" O.C. <br />U Q <br />z /z/D ' <br />I" '`AM I N G NOTES <br />V cn <br />— - O PROJECT NO. w <br />C I i'"LE BE USED IN ALL L)RI:I_ED .AND EPDXIED ANCHOR APPLICATIONS . 0 <br />2020.004115 <br />C'Nt 'ARCING S I Ei L t it Y Sc EMBEDDED TO THE SPECIFIED DEPTH, IN O LL <br />-i1JIt 7 GREATER T I LAIN 'SPECIFED ANCHOR DIAMETER,). z O <br />rr <br />d r'E : E AND VVU(DD b0: OM PLATE. MANUFACTURER'S = DRAWN <br />iL L f o . <br />;rI'. I I� -:ILi r! i _r _ -" <br />U DO 0 <br />!1_IS . I : r.�•. r: IJ i ALLAT�OINi <br />LU F 1 1 IFn _)ry I)r J!' G END=D FOR DRY USE ONLY UNO. ALL WATERPROOFING AND FIRE SAFETY CHKD: U) <br />E L I tE F ESP !r -t' T NTR.ACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. X EAF U) <br />I t1F T,,! CONNECTORS � r.. ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN <br />W w <br />CL J <br />N +- i\, ,�i J B Nl `, 'II ^ 'F TO EE PROVIDED BY TRUSS MANUFACTURER. Q Q <br />i ('i ri FLY :. i, 1) tN ,`.i C `.'�RrJEi�5 TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. X U <br />li- PLY , 'v ; L GIRDER LOCAL IONS -1-13 BE CONTINUOUS THROUGH FLOOR Q ��♦I11i11/U/!' (/) <br />E I' IC i; C_.C!r,, E FADER JAC;!4h:ING S' UD GROUPS) <br />rs'(N LA&/, i,� to <br />4 do TOENAI! S OR n (� <br />6d COMMON END NAILS. <br />i- ♦ G• i <br />)•'c r�- _ ti , ,LrTcc hrITS (3)8d iOE t t NG,EI m ♦ z <br />— <br />C iD S'i If Gt, :, GIRDER OR BEAM NO 85166 Q <br />j D_ If 1 V"JS A S tVC L.! (3k. J .. ! JRAL Pt_A,P;, UNO W (—DocuSigned by: .•.k �/ <br />�V HF_:=11 FILL: .'4� C B OR PLYWOOD <br />O 435 <br />_.�• :Ma 0 <br />�. 3�4��tD �Q �F tiL 1 <br />i� HI C ALJr-...•; <br />Q <br />O 05-22-2020 0 <br />�- w <br />U REVISIONS: <br />Q rNo. Description Date <br />w <br />CO I J <br />- - U <br />C7 - -- - co <br />O <br />J O <br />O z <br />= 0 <br />U <br />w <br />I- <br />X <br />W STm1 <br />a_ <br />Q <br />CMUNETAL CONNECTOR ENGINEERING <br />f'­2�j`J -ITHF7 tPTiOty PRO'✓IDEU 1S eNn1 EOUAL <br />rION 5H01Vtd <br />PL4,14 OF,', 1) AIL <br />