My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8213 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8213 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:00:01 AM
Creation date
2/27/2025 1:18:56 PM
Metadata
Fields
Template:
Building Plans
Street #
8213
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
452
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: 81B96B41-3A94-477C-9B97-507180D95065 <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />-- -- -- -- --4 — <br />a —_ 4 <br />\\\/\\/\\ <br />\//\\ ° a \ <br />/. <br />16„ VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0' 0" A.F.F. SEE ARCH <br />— - a -- — — (MAX 20" <br />° 4 ° 111, <br />l— , a _ DEEP) <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL `— VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*fBEARING CURB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />TOP OF SLAB 0,L <br />VAPOR BARRIER <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />I n <br />D•p L� 0 3 <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT <br />TO HAVE 6" BEND AT BOTTOM <br />CAST -IN -PLACE FOOTING SPECS — — <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />— ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />U-0" A. F.F. <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 ¢ U J (1) #4 OR #5 <br />WWF OR FIBERMESH > j Q Q U) CONT <br />n I• w U j <br />Uj <br />cn Q- <br />FINISH <br />0 GRADE <br />\//\//\ <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. o ,_ <br />FOOTING TO BEAR ON FIRM — \ / <br />UNDISTURBED SOIL —ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO — 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />TI <br />TEMWALL CURB SECTION <br />. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />MINIMUM 24" <br />36" MAX VARIES PER <br />ARCH PLANS <br />— <br />e 4 a <br />\\//\7r <br />12' MIN <br />j` <br />a <br />41 <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />ADDITIONAL NO.4 OR NO. 5 <br />BAR IN BRICK LEDGE <br />— <br />1 Q1 MONOLOTHIC F <br />a <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90° BEND @ 48" O.C. <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />ION - 36" MAX DEPTH <br />"NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"I" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />Qp o __ <br />U <br />0 <br />ri <br />rn <br />0 <br />N <br />Aft\ <br />,/ APEX <br />VAPOR BARRIER /. \ !\�/\\. \�\/� <br />\/\� 12" M I N �/� �j��j ///\/\ 0 N <br />FOOTING TO BEAR ON 6 OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN IL N <br />04 <br />12" UNDER 1 STORY WALL w/ cM <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J L L <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ LL! <br />(2) #5 OR (3) #4 CONTINUOUS J <br />tds i� <br />J � <br />true design studios <br />MONOLITHIC FOOTING SECTION z <br />1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: w <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY < SUITE 100, JACKSONVILLE, FL 32211 O <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />CONCRETE SLAB w/ 6x6 W C <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH p <br />0 IH09ON <br />a c ° o ° Q L <br />16" VAPOR BARRIER Q +� <br />D <br />0 <br />U <br />3 BEARING WALL FOOTING SECTION Z <br />w <br />O <br />w <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />_ U-0" A. F. F. O <br />SEE ARCH <br />'d a DETAILS <br />LO <br />8" MIN <br />V ) <br />8"x8" THICKENED 8" U) W <br />FTG AT w <br />STEP-DOWN, SEE VAPOR BARRIER z <br />PLAN <br />4Of <br />CURB STEP SECTION m LU O U) <br />W Q <br />w Q O <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL Z I '> Q a <br />6x6 W1.4 x W1.4 WWF w �++ <br />OR FIBERMESHF a Q J 2 <br />1ARIES1— <br />SEE ARCH � Q <br />(MAX 16") w W <br />//\�� // LL �— <br />12" MIN%\\�\\�\\�\\�\� Z r- <br />\, O Z <br />Lij <br />/ \ / 6" OPT. EXTENSION IN BRICK 0 <br />LOCATIONS ON FND PLAN d Z_ <br />ADDITIONAL NO. 4 OR NO. 5 OU LL <br />a <br />BAR IN BRICK LEDGE <br />Q W <br />� J <br />Abbott Park Q <br />GARAGE EXT WALL CURB SECTION J — <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 043-03 — <br />LU <br />FOLLOWING OCCUR: --- - <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" d Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. co <br />PROJECT NO LLI <br />CONCRETE SLAB W/ 6x6 0 2020.005388 <br />W1.4 x W1.4 WWF OR O LL <br />FIBERMESH Z DRAWN. 0 <br />- l � 0'-0" A F.F. - -� SEE ARCH C) DO 0 <br />a — — — -- -- (MAX 20" w <br />i - v I DEEP) cHKo- EAF <br />p- J <br />4" EXTENSION X V <br />UNDER BRICK VENEER �•``��(�N LA��i cn <br />12" UNDER 1 STORY WALL ����J-' GE1V/�9,��i <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : .• �,� S�.••.• �i Z <br />®o*00god <br />16" UNDER 2 STORY WALL Z <br />W/ (3) #4 OR (2) #5 CONT ; <br />13 <br />Li <br />6 BEARING CURB STEP SECTION O <br />TTFF npFF , <br />i <br />z 1P <br />I TYPICAL REINFORCING D <br />BARS AT THICKENED O 07-10-20 Q <br />FOOTING, SEE PLAN W <br />-- MIN 24" LONG #4 OR #5 w <br />REVISIONS' W <br />BAR SET AT MID -DEPTH U — <br />OF SLAB, TYP ALL LL.F- <br />RE-ENTRANT CORNERS Q No. Description Date <br />II c <br />-- --- -- ---- -- O H <br />LHOUSE SLAB O Z <br />- - _ 0 <br />RE-ENTRANT CORNER DETAIL v <br />w <br />(RECOMMENDED) �- <br />PLAN VIEW, DETAIL TYPICAL @ ALL W STm2mD <br />RE-ENTRANT CORNERS <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />VAPOR BARRIER <br />
The URL can be used to link to this page
Your browser does not support the video tag.