Laserfiche WebLink
)ocu5ign Envelope ID: 81B96B41-3A94477C-9B97-507180D95065 <br />Footer <br />Re -Bar (sized <br />according to <br />foundation plan) <br />s <br />#4 awg CU bare w/ 10' stubbed <br />outside of slab at service <br />location. Connect to footer steel <br />w/ (2) ground clamps 5' apart <br />a <br />UFER GROUND DETAIL <br />N.T.S. <br />ELECTRICAL RISER DIAGRAM <br />OPTIONAL OVERHEAD <br />SERVICE SAME AS 150 = #1 Copper or 2/ 0 Aluminum <br />UNDERGROUND 150 OR 200 200 = 2 /0 Copper or 4 /0 Aluminum in 2" <br />AMP SERVICE Conduit. <br />- A/C DISCONNECT <br />METER MAIN <br />Dlsc. #12 COPPER TO APPLIANCES AND GFI <br />-- �� 150 OR <br />200 AMP TYPICAL <br />ELECTRICAL #14 COPPER TO LIGHTS AND OUTLETS <br />PANEL #10 COPPER TO WATER HEATER <br />-- UNDGND #8 COPPER TO RANGE <br />SERV. BY <br />POWER CO. #6 COPPER TO HVAC <br />N.T.S. 0 #4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER: <br />A) APPROVED GROUNDING ROD WITH MINIMUM 8' DEPTH <br />B) BONDED TO CONTINUOUS FOOTING STEEL <br />INTERSYSTEM BONDING TERMINATION PER NEC 250.94 <br />NOTE: <br />ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />l� GENERAL ELECTRICAL NOTES <br />ABBREVIATIONS LEGEND <br />ALL ELECTRICAL DESIGN AND WORK SHALL BE /N STRICT <br />COMPLIANCE <br />WITH THE 2014 NATIONAL ELECTRIC CODE <br />ABV <br />ABOVE <br />AC <br />AIR CONDITIONER <br />• <br />PER NEC SECTION 210.12 (B) ALL 15A & 20A, 120V <br />AFF <br />ABOVE FINISHED FLOOR <br />BRANCH CIRCUITS SUPPLYING OUTLETS REQUIRE <br />AHU <br />AIR HANDLER UNIT <br />AFCI PROTECTION <br />BLK <br />BLOCK <br />CABS <br />CABINETS <br />• <br />CARBON MONOXIDE PROTECTION PER FLORIDA <br />CLG <br />CEILING <br />STATUTES 553.885 (2). TO BE INSTALLED WITHIN 10' <br />CHR <br />CHAIR RAIL <br />OF EVERY SLEEPING ROOM <br />COFF <br />COFFERED <br />COL <br />COLUMN <br />• <br />ALL OUTLETS SHOULD BE AFCI PER NEC - U.N.O. <br />COND <br />CONDENSER <br />CRN <br />CROWN MOULDING <br />• <br />PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />CVAC <br />CENTRAL VACUUM SYSTEM <br />RECEPTACLES INSTALLED OUTDOORS MUST BE <br />DBL <br />DOUBLE <br />GFCI-PROTECTED <br />DIAG <br />DIAGONAL <br />DR <br />DOOR <br />DRY <br />DRYER <br />• <br />PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />DW <br />DISHWASHEREB <br />RECEPTACLES INSTALLED WITHIN 6' OF SINK (IN <br />EYEBROW <br />NON -DWELLING OCCUPANCIES-i.e. OUTDOOR <br />FL <br />FLOOR LINE (MAT. CHANGE) <br />SUMMER KITCHENS RECEPTACLES) MUST BE <br />FLR <br />FLOOR <br />GFCI-PROTECTED <br />FP <br />FIREPLACE <br />FXD <br />FIXED <br />• <br />PER NEC SECTION 406.8(B)(1) 15A & 20A <br />FXT <br />FIXTURE <br />RECEPTACLES IN A WET LOCATION MUST BE WITHIN <br />GLS <br />GLASS <br />AN ENCLOSURE THAT IS WEATHERPROOF WHEN AN <br />HB <br />HOSE BIB <br />ATTACHMENT IS PLUGGED IN AN ALL NON -LOCKING <br />KS <br />KNEE SPACE <br />RECEPTACLES SHALL BE LISTED AS WEATHER <br />LAV <br />LAVATORY <br />RESISTANT <br />LT <br />LAUNDRY TUB <br />MRBL <br />MARBLE <br />• <br />PER NEC SECTION 406.11 IN DWELLING UNITS, ALL <br />MC <br />MEDICINE CABINET <br />15A & 20A, 15V RECEPTACLES SHALL BE LISTED AS <br />MIR <br />MIRROR <br />TAMPER -RESISTANT <br />MTL <br />METAL <br />OH <br />OVERHEAD <br />• <br />PER NEC SECTION 800.156 NO LESS THAN ONE <br />OPNG <br />OPENING <br />COMMUNICATION OUTLET SHALL BE INSTALLED <br />OPT <br />OPTIONAL <br />WITHIN EACH DWELLING UNIT <br />R & S <br />CLOTHES ROD and SHELF <br />REF <br />REFRIGERATOR <br />• <br />PER NEC SECTION R314.3 AND R315.1 SMOKE <br />SD <br />SOAP DISH <br />DETECTORS TO BE INSTALLED INSIDE EACH <br />SDLTS <br />SIDE LIGHTS <br />SLEEPING AREA <br />DOOR <br />SHD(2) <br />SHELVES <br />ELVES (QUANTITY) <br />• <br />ALL SMOKE ALARMS SHALL BE LISTED AND LABELED <br />SHWR <br />SHOWER <br />IN ACCORDANCE WITH UL 217, PER FBC 314.1. GC TO <br />TB <br />TOWEL BAR <br />INSTALL- KIDDE MODEL # 14618A SMOKE ALARM, OR <br />TPH <br />TOILET PAPER HOLDER <br />APPROVED EQUAL <br />T&S <br />TUB and SHOWER <br />TEMP <br />TEMPERED <br />• <br />PROVIDE GAS DROPS AS PER COMMUNITY ONLY <br />TR <br />TRANSOM <br />VOL <br />VOLUME <br />• <br />JUNCTION BOX AT WATER HEATER, RANGE AND/OR <br />WC <br />WATER CLOSET <br />DRYER TO BE 220V IN NON GAS COMMUNITIES, AND <br />WD <br />WOOD <br />110V IN COMMUNITIES THAT HAVE GAS OPTIONS <br />WH <br />WATER HEATER <br />PROVIDE APPROPRIATE RECEPTACLE PER <br />WNCT <br />WAINSCOT <br />APPLIANCE <br />WS <br />WATER SOFTENER <br />WASH <br />WASHER <br />• <br />ALL LAMPS SHALL BE HIGH -EFFICACY TO COMPLY <br />WITH FBC-EC R404.1 - (LOW -VOLTAGE LAMPS <br />EXCLUDED). <br />• <br />PER FBC-R M1305.1 A LEVEL WORKING SPACE NOT <br />LESS THAN 30" DEEP AND 30" WIDE SHALL BE <br />PROVIDED IN FRONT OF THE CONTROL SIDE OF ANY <br />APPLIANCE <br />ROOF NOTES <br />• INSTALL ROOF VENTING PER MFR WRITTEN <br />INSTRUCTIONS PER FBC R806 <br />• ALL OVERHANG DIMENSIONS ARE TO EDGE OF <br />RAFTER. REFERENCE WALL SECTIONS/DETAILS <br />FOR ALL OVERHANGS NOT DIMENSIONED. <br />• ALL UNDERLAYMENT MUST BE INSTALLED IN <br />COMPLIANCE WITH FBC R501.1.1 <br />• EACH 4' OFF RIDGE VENT REQUIRES (1) 46" x 3" CUT <br />OUT IN ROOF SHEATHING PER MFR WRITTEN <br />INSTRUCTIONS <br />ROOF VENT CALCULATION <br />FORMULA: <br />1 SQUARE INCH VENT FOR EVERY 300 SQUARE INCHES <br />OF CEILING <br />*144 SQ. IN. = 1 SQ, FT. <br />BLDG. CEILING (SF) x 144 = BLDG (SQ. IN.) <br />BLDG. (SQ. IN.) 1300 = SQ. IN. OF VENT REQUIRED <br />SQ. IN. OF VENT REQUIRED / 2 = 50% AT HIGH AND 50% <br />AT LOW. <br />PER FBC SECTION R806.2: 40% MIN, BUT NOT MORE <br />THAN 50% OF VENTILATION MUST BE PROVIDED BY <br />VENTILATORS LOCATED NO MORE THAN 3'-0" BELOW <br />THE RIDGE OR HIGHEST POINT OF THE SPACE <br />BASIS OF CALCULATION: ("OR EQUAL" ACCEPTABLE) <br />(a) OFF RIDGE VENTS - STAMPCO W/ 36 SQ IN (NFVA) <br />PER LINEAL FT <br />(b) SOFFIT VENTS - GP T3-1/3" FULL VENT PERFORATED <br />W/ 9.19 SQ IN (NFVA) PER LINEAL FT <br />CALCULATED LINEAL FOOT OF SOFFIT VENT SHALL <br />NOT INCLUDE NON -VENTED FIRE RATED SOFFIT <br />LOCATED LESS THAN 5' FROM PROPERTY LINE <br />EXTERIOR ELEVATION GENERAL NOTES <br />• FRONT ELEVATIONS BANDING, MOLDING, <br />COLUMNS AND TRIM SHALL RECEIVE A SAND <br />FINISH. SEE ELEVATION FOR DEPTH OR RAISED <br />BANDING <br />• SIDE AND REAR ELEVATIONS BANDING AROUND <br />WINDOWS AND DOORS MAY BE OPTIONAL PER <br />COMMUNITY SPECS - SEE COMMUNITY <br />SPECIFICATIONS OR CONSULT THE <br />CONSTRUCTION MANAGER. ALL BANDING SHALL <br />RECEIVE A SAND FINISH <br />• ROOF COVERING SEE COMMUNITY <br />SPECIFICATIONS OR CONSULT THE <br />CONSTRUCTION MANAGER. SEE STRUCTURAL <br />SHEETS FOR SHEATHING REQUIREMENTS <br />• FLASHING SHALL BE INSTALLED AT WALL AND <br />ROOF INTERSECTIONS, DECK AND WALL <br />INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN <br />ROOF SLOPE OR DIRECTION, AND AROUND ROOF <br />OPENINGS <br />I <br />• WINDOW PAN FLASHING SHALL BE IN <br />ACCORDANCE WITH FBC R703.8 <br />• WALL HEIGHTS VERIFY ALL BEARING WALL <br />HEIGHTS WITH FINAL TRUSS LAYOUTS <br />• LATH PER FBC R703.7.1, LATH AND LATH <br />ATTACHMENTS SHALL BE OF <br />CORROSION -RESISTANT MATERIALS. EXPANDED <br />METAL OR WOVEN WIRE LATH SHALL BE <br />ATTACHED WITH 11/2-INCH-LONG (38 MM), 11 GAGE <br />NAILS HAVING A 7/16-INCH (11.1 MM) HEAD, OR <br />7/8-INCHLONG (22.2 MM), 16 GAGE STAPLES, <br />SPACED NOT MORE THAN 6 INCHES (152 MM), OR <br />AS OTHERWISE APPROVED <br />• PLASTER PER R703.7.2, PLASTERING WITH <br />PORTLAND CEMENT PLASTER SHALL BE NOT LESS <br />THAN THREE COATS WHERE APPLIED OVER METAL <br />LATH OR WIRE LATH AND SHALL BE NOT LESS <br />THAN TWO COATS WHERE APPLIED OVER <br />MASONRY, CONCRETE, PRESSURE -PRESERVATIVE <br />TREATED WOOD OR DECAY -RESISTANT WOOD AS <br />SPECIFIED IN SECTION R317.1 OR GYPSUM <br />BACKING. IF THE PLASTER SURFACE IS <br />COMPLETELY COVERED BY VENEER OR OTHER <br />FACING MATERIAL OR IS COMPLETELY <br />CONCEALED, PLASTER APPLICATION NEED BE <br />ONLY TWO COATS, PROVIDED THE TOTAL j <br />THICKNESS IS AS SET FORTH IN TABLE R702.1(1). <br />ON WOOD -FRAME CONSTRUCTION WITH AN <br />ON -GRADE FLOOR SLAB SYSTEM, EXTERIOR <br />PLASTER SHALL BE APPLIED TO COVER, BUT NOT <br />EXTEND BELOW, LATH, PAPER AND SCREED. THE <br />PROPORTION OF AGGREGATE TO CEMENTITIOUS <br />MATERIALS SHALL BE AS SET FORTH IN TABLE <br />R702.1(3) <br />• WEEP SCREED PER R703.7.2.1 A MINIMUM <br />0.019-INCH (0.5 MM) (NO. 26 GALVANIZED SHEET <br />GAGE), CORROSION -RESISTANT WEEP SCREED OR <br />PLASTIC WEEP SCREED, WITH A MINIMUM <br />VERTICAL ATTACHMENT FLANGE OF 31/2 INCHES <br />(89 MM) SHALL BE PROVIDED AT OR BELOW THE <br />FOUNDATION PLATE LINE ON EXTERIOR STUD j <br />WALLS IN ACCORDANCE WITH ASTM C926. THE <br />WEEP SCREED SHALL BE PLACED NOT LESS THAN <br />4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES <br />(51 MM) ABOVE PAVED AREAS AND SHALL BE OF A <br />TYPE THAT WILL ALLOW TRAPPED WATER TO I <br />DRAIN TO THE EXTERIOR OF THE BUILDING. THE <br />WEATHER -RESISTANT BARRIER SHALL LAP THE <br />ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL <br />COVER AND TERMINATE ON THE ATTACHMENT <br />FLANGE OF THE WEEP SCREED <br />• WATER -RESISTIVE BARRIERS PER R703.7.3, <br />WATER -RESISTIVE BARRIERS SHALL BE INSTALLED <br />AS REQUIRED IN SECTION R703.2 AND, WHERE <br />APPLIED OVER WOOD -BASED SHEATHING, SHALL <br />INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE <br />BARRIER WITH A PERFORMANCE AT LEAST <br />EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. <br />THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />INDEPENDENTLY SUCH THAT EACH LAYER <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND <br />ANY FLASHING (INSTALLED IN ACCORDANCE WITH <br />SECTION R703.4) INTENDED TO DRAIN TO THE <br />WATER -RESISTIVE BARRIER IS DIRECTED <br />BETWEEN THE LAYERS <br />GENERAL NOTES <br />• ALL CONSTRUCTION SHALL MEET THE LATEST <br />EDITION OF CODES ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES <br />• PER FBC R302.5 NO OPENINGS FROM A PRIVATE <br />GARAGE ARE PERMITTED DIRECTLY INTO SLEEPING <br />AREAS. ALL OPENINGS SHALL HAVE SOLID WOOD, <br />INSULATED STEEL OR 20 MIN. FIRE RATED DOORS <br />NOT LESS THAN 1-3/8 INCHES THICKNESS, EQUIPPED <br />WITH A SELF CLOSING DEVICE. ALL DUCTS IN THE <br />GARAGE OR PENETRATING THE WALL OR CEILING <br />SEPARATING THE GARAGE AND DWELLING SHALL BE <br />CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1 INCH <br />MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD, OR <br />OTHER APPROVED MATERIAL AND SHALL HAVE NO <br />OPENINGS INTO THE GARAGE <br />• PER FBC TABLE R-302.6 GARAGE SHALL BE <br />SEPARATED FROM RESIDENCE AND IT'S ATTIC W/ <br />MIN. 1/2" GYP BOARD ATTACHED IN ACCORDANCE <br />WITH TABLE R702.3.5, HABITABLE ROOMS SHALL BE <br />SEPARATED FROM ROOM ABOVE W/ MIN 5/8" TYPE <br />"X" GYP BOARD, WHERE THE SEPARATION IS A <br />FLOOR -CEILING ASSEMBLY. ANY STRUCTURE <br />SUPPORTING THE ASSEMBLY SHALL BE PROTECTED <br />W/ MIN 1/2" GYP BOARD <br />• PER FBC R302.12 IN COMBUSTIBLE CONSTRUCTION <br />WHERE THERE IS USEABLE SPACE BOTH ABOVE <br />AND BELOW THE CONCEALED SPACE OF A <br />FLOOR/CEILING ASSEMBLY, DRAFT STOPS SHALL BE <br />INSTALLED SO THAT THE AREA OF THE CONCEALED <br />SPACE DOES NOT EXCEED 1,000 SQUARE FEET. <br />DRAFT STOPPING SHALL DIVIDE THE CONCEALED <br />SPACE INTO APPROXIMATELY EQUAL AREAS AND <br />INSTALLED PER FBC R302.12 & R302.12.1 <br />• PER FBC R-312.1 PORCHES, BALCONIES OR RAISED <br />FLOOR SURFACES LOCATED MORE THAN 30" ABOVE <br />FINISHED FLOOR OR GRADE SHALL HAVE GUARDS <br />NOT LESS THAN 36" IN HEIGHT, PER FBC R-312.1.2 <br />OPEN SIDES OF STAIRS WITH A TOTAL RISE OF <br />MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE <br />SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT <br />MEASURED VERTICALLY FROM THE NOSING OF THE <br />TREADS <br />• PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN <br />SIDES OF STAIRWAYS, RAISED FLOOR AREAS, <br />BALCONIES AND PORCHES SHALL HAVE <br />INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES <br />WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" <br />OR MORE IN DIAMETER <br />• PER FBC R-308.4.5 GLAZING IN WALLS, ENCLOSURES <br />OR FENCES CONTAINING OR FACING HOT TUBS, <br />SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR <br />SWIMMING POOLS WHERE THE BOTTOM EXPOSED <br />EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />MEASURED VERTICALLY ABOVE ANY STANDING OR <br />WALKING SURFACE, SHALL BE CONSIDERED A <br />HAZARDOUS LOCATION. G.C. TO VERIFY IF <br />HOMEOWNER SELECTS ANY OF THESE ITEMS <br />LISTED. IF ANY OF THESE ITEMS LISTED IS <br />INSTALLED, SUCH GLAZING FACING THOSE ITEMS IS <br />TO BE TEMPERED <br />• PER FBC R312.2, PROVIDE WINDOW FALL <br />PROTECTION IN ACCORDANCE WITH R312.2.1 AND <br />R312.2.2 <br />• GAS OPT. PER COMMUNITY. VERIFY WITH BLDR <br />• C.J. = RECOMMENDED MASONRY CONTROL JOINT <br />LOCATION <br />• ALL FINISHES, MATERIALS, HOUSEWRAP, WINDOW <br />AND DOOR FLASHING, TAPING AND SEALANTS TO BE <br />INSTALLED PER BUILDER PROVIDED <br />SPECIFICATIONS OR MFR WRITTEN INSTRUCTIONS <br />• ALL FINISH DETAILS & TYPICAL PLAN NOTES <br />PROVIDED BY BUILDER IN ACCORDANCE WITH <br />TYPICAL BUILDER SPECIFICATIONS <br />• REFER TO STRUCTURAL ENGINEERING DRAWINGS <br />FOR ALL EXTERIOR WALL STUD SPECIES, SIZES AND <br />SPACING <br />E <br />O <br />U <br />o ° <br />N 0 <br />APEX C_ <br />Cq 0 <br />r- <br />N <br />N <br />co <br />J <br />LL. -C <br />w tds J <br />J.6 <br />� <br />true design studios <br />O <br />co -� <br />U 9000 REGENCY SQUARE BLVD. c <br />SUITE 100, JACKSONVILLE, FL 32211 O <br />o <br />O <br />w nowsmommmaw <br />H- <br />N ' u7 <br />D#HOM <br />t <br />J i <br />llb <br />w <br />Q C1 <br />0 <br />U <br />Z <br />w <br />0 <br />w <br />Of <br />O <br />O <br />0 <br />O <br />I` <br />L <br />ti <br />O u� <br />Z w <br />MM <br />W <br />w <br />Z Z W <br />Uj O U)co <br />w <br />w Q <br />w O <br />Z_ <br />Z > 0 Q <br />m w o <br />o � J w <br />LL1 w <br />O �/ <br />ILL <br />LL <br />Z Q `- <br />O Z <br />F- O <br /><C 0 <br />0� w <br />F- <br />a Z <br />0 a <br />U LL <br />0 w <br />w Abbott Park <br />O U <br />-J U) <br />U- LOT 043-03 0 <br />Q w <br />H <br />U Q <br />Z_ Z <br />0 <br />0(1)O PROJECT NO: w <br />j 2020.005388 0 <br />LL. <br />Z O DRAWN: _ <br />v DO o <br />wCHKD, U-) <br />JAC x <br />w w <br />CL <br />Q U <br />Q <br />U) <br />�- C7 <br />m Z <br />0 <br />w <br />Z <br />O <br />w <br />� O <br />a Z <br />Z 3: <br />U) a <br />0 07-10-20 0 <br />w <br />U REVISIONS: Uj <br />U_ x <br />Q No. Description Date w <br />U) J <br />-- Q <br />>- U <br />O ~O <br />O Z <br />= 0 <br />U <br />w <br />x AOOO <br />w <br />D_ <br />Q <br />