Search
8235 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8235 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:17:23 AM
Creation date
2/27/2025 1:19:19 PM
Metadata
Fields
Template:
Building Plans
Street #
8235
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2647
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)ocuSign Envelope ID: F282BDE9-B3A3-4C42-AAFB-342FED633458 <br />• EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D D <br />D EXISTING FOUNDATION. <br />I p e <br />I <br />D \ � <br />• D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDC <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE wl <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVET <br />FLUSH w/ 3000psi CONCRETE. <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />-° - °- - - - - (MAX 20" <br />° 4 ° ° e ° e DEEP) <br />4 <br />" <br />EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*-BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° 4 a <br />16" <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />L <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWALL MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 2 <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />I a/-6x6 W1.4 x W1.4 WWF <br />- - - - - - -� - - - - -°- OR FIBER MESH <br />U)O ° •I ° ° g ° °° #4OR#5 <br />REINFORCING PER <br />Z • • ° ° ° MONOLITHIC FOOTING <br />SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />MINI 12" <br />LOCATE VERTICAL <br />REINFORCEMENT IN LAST <br />STEMWALL CELL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />*ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />t\ FIBERMESH <br />'V <br />VAPOR BARRIER <br />SEE NOTES (MAX 16") v <br />0 <br />STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a, p <br />ALL OTHER EXTERIOR WALL `li O <br />CLADDING - MIN 8", U.N.O. ON ARCH O p <br />� APES ° <br />\/� <br />12' MIN \\/\\/\\/\\/\\/\� N U <br />00 <br />%\//\\\ O N <br />O CU <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED <br />SOIL LOCATIONS ON FND PLAN <br />� <br />N <br />M <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />J/00.�\ <br />BAR IN BRICK LEDGE <br />LIL <br />16" UNDER 2 STORY WALL w/ <br />Ld <br />tds <br />(2) #5 OR (3) #4 CONTINUOUS <br />J <br />-6 <br />z <br />true design studios <br />M_ ONOLITHIC FOOTING SECTION <br />1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />0 <br />FOLLOWING OCCUR: <br />Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />U <br />9000 REGENCY SQUARE BLVD. <br />CD <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />ui <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />O <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />O <br />O <br />CONCRETE SLAB w/ 6x6 <br />W <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH <br />~ <br />® <br />_ <br />N <br />N <br />J r <br />r <br />m Amf <br />W <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />0 <br />W <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0'-0" A.F.F. O <br />4 -ly SEE ARCH <br />DETAILSlip 4 LO <br />FLOATING CONCRETE --- w U-BLOCK W/ \, \ \ ,� 8" MIN <br />SLAB W/ 6x6 W1.4xW1.4 PLUW<u <br />J (1) #4 OR #5 //U V J <br />WWF OR FIBERMESH ¢ CONT \\ /, Z W <br />,- �� o 8"x8" THICKENED 8" w <br />FINISH FTG AT VAPOR BARRIER LU LL <br />O GRADE STEP-DOWN, SEE Z <br />\/\/� \ \\ PLAN U ` W <br />CURB STEP SECTION M w <br />#4 OR #5 VERT REINFORCING /\\/\\/\\/\\/ \ Q <br />UP TO 3 COURSES: 72" O.C. �" I \//\\//\\// /// / -- W <br />4 TO 5 COURSES: 48" O.C. \ p o ,`` 8" UNDER MASONRY WALL Z > O <br />-- Q <br />\\ L • -o 6" UNDER WOOD WALL `Z M W Q <br />CONCRETE SLAB W/ W <br />6x6 W1.4 x W1.4 WWF ° W <br />OR FIBERMESH VARIES SEE ARCH Q J <br />FOOTING TO BEAR ON FIRM - - - - - - <br />UNDISTURBED SOIL - ADDITIONAL #4 OR - - ° ° 4$ (MAX 16") IY W [ <br />#5 IN BRICK LEDGE ° X <br />/\\//\\//\\//�// //\//\//\/��/7^' O <br />VERT REINFORCEMENT TO /\\/\\/\�\/\/ \ \ \�\/\/\/\/\/\ LL <br />HAVE 6" BEND @BOTTOM - 4" OPT BRICK LEDGE \\/ \ ° �,/ 12" MIN\\/\\/\\/\\/\� Z <br />NOTED ON FND PLAN \// a \//�/\\\//\\\ Z <br />\\ ° 4\\\/�\//�\///\\ U O <br />CAST -IN -PLACE FOOTING SPECS VAPOR BARRIER <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT / / / LLJ 6" OPT. EXTENSION IN BRICK Q <br />LOCATIONS ON FND PLAN a Z <br />7 STEMWALL CURB SECTION 12" UNDER 1 STORY WALL w/ O <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK (2) #5 OR (2) #4 CONTINUOUS ADDITIONAL LEDO. 4 E NO. 5 U LJL <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ 0 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS J <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. (2) #5 OR (3) #4 CONTINUOUS OfABBOTT PARK Q <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY 0 _ 0 <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. GARAGE EXT WALL CURB SECTION Q LOT 041-03 W <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE LIL <br />FOLLOWING OCCUR: <br />H <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. CD PROJECT NO W <br />CONCRETE SLAB W/ 6x6 O 2021.006630 0 <br />LIL <br />W1.4 x W1.4 WWF OR O 0 <br />FIBERMESH Z - -. - - <br />0'-0" A.F.F. SEE ARCH U DRAWN: KME Q <br />(MAX 20" W CHKD: LO <br />3 YZ' CONCRETE SLAB W/ 6x6 \ a -° _ , DEEP) F- imp <br />(1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH x - <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. \\% j\ o • ° T a Q <br />4" EXTENSION Xa U <br />36" MAX VARIES PER o - - - - - - - - - UNDER BRICK VENEER ¢ �%%%t11IN 1 Lq 111,,E W <br />ARCH PLANS \ \ \ ; _ _ %% S� N/ �� <br />/ T \ \ /\\//�/ 12" UNDER 1 STORY WALL VAPOR BARRIER m ,�� •.••��G E Ns�...• i� Z <br />\\/\\ \\ \/\\ �� / \ w/ (2) #4 OR (2) #5 CONT <br />\/\ -- - � N o 8 5166 ,� <br />/. ° VAPOR BARRIER 16" UNDER 2 STORY WALL = yt <br />12" MIN ° \ <br />UNDISTURBED SOIL ON FIRM Z * :• DoeuSigned by: <br />w/ (3) #4 OR (2) #5 CONT <br />\\ �' BEARING CURB STEP SECTION O :� 3f'G67WACOf,435. = ' <br />6" OPT. EXTENSION - <br />dO <br />w . � . <br />IN BRICK LOCATIONS b �����'< O R 10 P \�,�� Z <br />ON FND PLAN 12" UNDER 1 STORY WALL W/ (2) - Z ON A`��G <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT (A �'rrrr111>i10 <br />BAR IN BRICK LEDGE TYPICAL REINFORCING w <br />16" UNDER 2 STORY WALL W! (3) <br />BARS AT THICKENED Q 05-17-2021 Q <br />I SEE PLAN <br />#4 OR (2) #5 CONT FOOTING, F- W <br />MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH MIN S LONG ID -E #5 ~ w <br />1 I U REVISIONS: <br />BAR SET AT MID -DEPTH � - 1:OF SLAB, TYP ALL Q NO. Description Date ~ <br />`NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" I RE-ENTRANT CORNERS J <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG - - - - - <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS I- - - - <br />TWO CHOICES: - O O <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION HOUSE SLAB O Z <br />OF SOIL. <br />2. USE STEMWALL FOOTING U Q <br />RE-ENTRANT CORNER DETAIL W <br />(RECOMMENDED) ~ <br />PLAN VIEW, DETAIL TYPICAL @ ALL W ST=2mD <br />RE-ENTRANT CORNERS i1 <br />CMU/METAL CONNECTOR ENGINEERING¢ <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />U) <br />a) <br />Q:¢ o <br />VAPOR BARRIER /�\/�\\uJ <br />W o "' <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM #5 . //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />