8249 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8249 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:30:22 AM
Creation date
2/27/2025 1:19:33 PM
Metadata
Fields
Template:
Building Plans
Street #
8249
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2645
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 804C66C7-1A16-44B1-A7C7-0002ED72E2B6 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER) <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --/ <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y2" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/#5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />%" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2' WEDGE BOLT W/ MIN 4'/2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />I� <br />a ° <br />a <br />\\/\\ d \ <br />/\ I <br />a <br />7-7 <br />EXTERIOR WALL <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYI <br />ROOF -TO' <br />CONNE( <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 12" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />FOR MISLOCATION <br />FASTEN 2x6 NO. 2 S <br />TO TRUSS W/ MIN (1 <br />FOR MISLOCATION <br />INSTALL NEW MAS( <br />STRAP TO INSIDE F <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />#5 CONT. <br />a <br />Q <br />D (1) #4 OR #5 BAR AT CORNERS <br />N WITH MIN. 25" LAP <br />z_ <br />#5 CONT. <br />-o <br />D <br />0 <br />o o <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />3, ALL INTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7, FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />(1) #c <br />STEP DOWN TIE -BEAM <br />U <br />0 <br />N <br />N <br />N <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 11/4" <br />PER MANUF, <br />3" <br />5" <br />11/2' <br />3 �4' <br />37 6 <br />5„ <br />111116 <br />33/4, <br />3 3/4, <br />6„ <br />2 j4, <br />33/4„ il <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS W DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %s' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED 'W) <br />1x_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS. UNO) <br />AM1,11\ <br />0 <br />U <br />O <br />O <br />Cr <br />APEX <br />0 <br />0 <br />N <br />(D <br />N <br />i <br />(i5 <br />CV <br />co <br />J <br />S� <br />``� <br />LL <br />t <br />_C <br />S <br />J <br />� <br />true des, n studios <br />> <br />O <br />U) <br />U <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />p <br />o <br />O <br />W <br />�a� �o ���a�a � �� <br />co <br />I` <br />Cr. <br />U)04RHO190N, <br />N <br />3 f. Q ' =�$ <br />t <br />e <br />w <br />Q Q. <br />U Q <br />U <br />Z <br />W <br />0 <br />W <br />w <br />O <br />O <br />O <br />a) <br />>= <br />ti <br />d <br />O Q U)z LL] <br />U <br />U) < L.1_.J <br />w <br />W <br />z z -J w <br />120 Lu O u) <br />w Q <br />W <br />W <br />Z_ <br />> Q Q <br />W m w <br />o � W W <br />Liw <br />O <br />J X <br />ILL <br />Z Z <br />O O <br />Q 0 <br />rY w <br />m _z <br />0 <br />O a <br />U LL <br />ABBOTT PARK Q <br />O U <br />LL LOT 040-03 0 <br />Q w <br />I- <br />C) a <br />z z <br />O U) <br />O PROJECT NO w <br />J 2021.006629 <br />O ILL <br />Z O <br />DRAWN: <br />U KME o <br />w U0 <br />CHKD: <br />MJP <br />x <br />w w <br />� J <br />Q U <br />('• \N LgNf, .,�. U <br />m �••� `C•E•N SF'.9 z <br />0 No 85166 <br />W Q <br />Zr <br />= Dm,S,,gned by: = <br />LU O'•• DA`E:'[1EF435•'•/,�` U) <br />Al <br />z �i�SS /0 N A E� .�`�� 3: <br />Q <br />O 05-18-2021 p <br />1— w <br />U REVISIONS: <br />Q No. Description Date W <br />O 1— <br />J <br />Z Z <br />= 0 <br />U <br />W <br />H <br />X <br />W ST=5 <br />n <br />CMUIMETAL CONNECTOR ENGINEERING <br />