Laserfiche WebLink
)ocuSign Envelope ID: 2879FFE4-64D7-4056-8E51-057CBF46E1EB <br />TRUSS TO TOP PLATE, <br />MOISTURE BARRIER <br />UNO: <br />BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT <br />NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT <br />VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR <br />HAVE 10" STANDARD <br />SDWC15600 <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />.•P►01ral:11:4i. ' <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y2" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />I , ARCHITECTURAL) <br />_ PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />\\_(1) COURSE CMU BOND <br />BEAM W/#5 CONTINUOUS <br />7 <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />'/2' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />Y2" WEDGE BOLT W/ MIN 4'/2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYF <br />ROOF -TO' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 12" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN 1 <br />FOR MISLOCATIO <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />-CORNERS <br />'CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />(1)#E <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4' OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/2, <br />3 �4' <br />37 s <br />51, <br />115/16 <br />3 3/4 <br />3 3/4" <br />6" <br />2 %4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS '/4' DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED '/<") <br />1x_ PT NAILER <br />BUILT UP 2x_ ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />U <br />O <br />O O <br />APES <br />co N <br />CD <br />4 <br />r <br />N <br />co <br />i <br />J <br />U_ <br />W tds J <br />J-6 <br />a)trut', design studios <br />Z <br />O <br />U) <br />9000 REGENCY SQUARE BLVD. (V <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 r!, <br />p': <br />OI <br />Chi <br />W r` <br />F— <br />w, <br />wi <br />IHOUMN' zi <br />J°' `� <br />p A...,: �y:z \ <br />LU <br />Q - <br />W <br />U <br />Z <br />W <br />0 <br />W <br />ir <br />O <br />O <br />O <br />O <br />ti <br />d' <br />o Q � <br />Z 1i1 <br />W < W <br />w 0. <br />W <br />J z w <br />ULI O cn <br />m <br />w <br />w Q <br />w Q <br />z <br />3 > Q Q <br />w w 0 <br />Q J W W <br />w ti <br />OJ �' X <br />LL <br />LL <br />Z Z <br />O O <br />a 0 <br />Iz w <br />O I ­_a z <br />o <br />U LL <br />W <br />ABBOTT PARK Q <br />O U <br />J U) <br />"- LOT 038-03 0 <br />Q w <br />U Q <br />Z Z <br />CD <br />U) <br />OPROJECT NO w <br />-j 2021.006628 0 <br />O U_ <br />Z O <br />DRAWN: <br />U KME o <br />CHKD: MJP U) <br />x U) <br />w W <br />� U <br />Q♦��„� cn <br />co`�. .��G•E IVS�.'9 •� Z <br />W <br />No 85166 <br />Z Q <br />= Do Signed by: <br />ET AT, �, U) <br />44/ <br />v <br />Q O R �• �j�` �� Z_ <br />U)-.1s r0 i i Air,` <br />Q <br />O 05-17-2021 0 <br />1= W <br />U REVISIONS: <br />Q No. Description —ate W <br />co J <br />z z <br />= O <br />U � <br />w <br />H <br />X <br />W ST=5 <br />d <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />