ocuSign Envelope ID: FC1A8297-BD99-4D7E-BDDF-B7BADABCD430 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER---/ <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --/ <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />E <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 12" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />'/z" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2" WEDGE BOLT W/ MIN 4'/2" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />8" PARTIALLY GROUTED <br />- EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />- PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />Q <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />Z <br />REINFORCING W/ MIN 30" LAP <br />g <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />a a° MASONRY) <br />° � l a <br />711 <br />4 <br />° \ <br />/\ <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />ROOF-- <br />CONr <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 Y2" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />FOR MISLOCA I IO"' " <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN <br />FOR MISLOCATIO <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />-CORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />0 <br />U <br />0 <br />N <br />0 <br />N <br />POURED CELL W #5 BAR CbNT <br />FROM BEAM T FOOTING <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/4'' OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/2, <br />31/4" <br />37 fi <br />5„ <br />115/16 <br />3 3/4 <br />3 3/4° <br />61, <br />2 �4, <br />33/4, <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS Y4" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %s' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1X_PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />` <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED '/<") <br />1x_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1x_ 006 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOOR/WINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />E <br />M,,A\ O <br />A > <br />y <br />O <br />O <br />APEX <br />0 <br />00 <br />V <br />O <br />X <br />Q) <br />O <br />N <br />u_ <br />tds <br />W <br />J <br />_! <br />Q <br />1e"sera 5t� ei ?� <br />> <br />Z <br />O <br />U <br />9000 REGENCY SQUARE BLVD. <br />Q <br />SUITf 100, JACKSONVILLE, FL'32211 <br />ui <br />-� <br />O <br />o <br />Oin <br />i <br />W <br />H <br />j <br />an <br />ii-RHOMN"'41 <br />N <br />7 <br />\,\i,#­,q,,,,�, i ittiZv\ <br />k A 40P <br />ow <br />uj <br />Q4- <br />0 <br />Z <br />W <br />0 <br />W <br />O <br />O <br />O <br />O <br />ti <br />d>N <br />L0 <br />t` <br />a u) <br />Z w <br />W w <br />Z _! z Lu <br />U w <br />LLJ _O co <br />m <br />w Q <br />w <br />W <br />Z_ <br />> Q Q <br />w w o <br />o � � w w <br />w <br />O <br />J X <br />z a L- <br />z <br />O Z <br />O <br />Q o <br />Df w <br />z <br />O 0- <br />0 LL <br />W <br />ABBOTT PARK Q <br />O U <br />� cn <br />U- LOT 021-02 0 <br />U Q <br />Z Z <br />} 0 <br />OPROJECT NO W <br />J 2021.006627 <br />O LL <br />Z DRAWN: O <br />U KME o <br />CHKD. MJP W <br />X W <br />w w <br />� U <br />Q `�����ti��i�iii c!) <br />M LA <br />mG•E Z_ <br />W _ No 85166 Z - . . - QN <br />D*uSigned by: LL <br />• r 0 <br />O :4_ <br />T.4TE yOF <br />w O 3F4671DACDEF�JS:(/ <br />R A. <br />�ZQ <br />Z S�%%`�` <br />n <br />Q <br />D Of <br />O 05-18-2021 p <br />w <br />U REVISIONS: <br />Q No. Description Dated w <br />U) J <br />Q <br />� U <br />U) <br />O �- <br />JO O <br />= O <br />U 0 <br />w <br />F- <br />X <br />W ST=5 <br />a <br />CMU/METAL CONNECTOR ENGINEERING <br />