My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8273 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8273 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:10:24 PM
Creation date
2/27/2025 1:20:19 PM
Metadata
Fields
Template:
Building Plans
Street #
8273
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2753
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9ED12F2D-B41C-4448-BA66-5E8CEB9C3CDC <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE j —I <br />STRIP OF WWF FROM F.F.E. TO --- <br />MIN. 6" BELOW GRADE. WWF TO _ <br />EXISTING FOUNDATION FACE w/ D ° ° 1 <br />(2) ROWS OF 3/6" DIA. TAPCONS — D D ° — — — — — — D D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />° EXISTING FOUNDATION. <br />D ° <br />j <br />D \ <br />° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL — p <br />WHERE NEEDED j <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO — — <br />BOTTOM OF FTG. WWF TO _ <br />EXISTING FOUNDATION FACE w/ ° — — — — — — <br />3 ° D D D D ° D -- — <br />D <br />(2) ROWS OF /6" DIA. TAPCONS <br />° <br />OR CUT NAILS @ 24" O.C. COVER D ° <br />FLUSH w/ 3000psi CONCRETE. <br />° EXISTING FOUNDATION <br />D ° <br />° D <br />i <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />— — a — — — (MAX 20" <br />DEEP) <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*_REARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />— - — -- -� <br />d ° d <br />Q ° <br />/ VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />_ 1 <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />8" CMU CHAIR BLOCK W/ (1) #5 ---\ <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />U)p <br />�F_ <br />OU) <br />UZ <br />a <br />LOCATE VERTICAL AND TIE INTO STEMWALL F <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />MONO LITHIC SLAB <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4OR#5 <br />REINFORCING PER <br />MONOLITHIC FOOTING <br />SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />OOTI NG <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB a BLOCK W/ (1) #4 OR #5 CONT. <br />2 rn <br />Q Q O <br />VAPOR BARRIER ��\\� j w o <br />Q <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM ��\\/ \\\%\\ \ \ ADDITIONAL #4 OR <br />//. i #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />TO HAVE 6" BEND AT BOTTOM N <br />CAST-IN-PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />*_STEMWA LL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 P(Lor:u( <br />(1) #4 OR #5 <br />WWF OR FIBERMESH > Q U) CONT <br />LLJ <br />p <br />— — — — — FINISH <br />0 GRADE <br />#4 OR #5 VERT REINFORCING \\/ - �\%/��x\ <br />UP TO 3 COURSES: 72" O.C. % \ 1 \f �/ <br />\ j \/\/\/ <br />4 TO 5 COURSES: 48" O.C. o <br />o ° <br />FOOTING TO BEAR ON FIRM -- <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />3'/2' CONCRETE SLAB W/ 6x6 <br />#4 OR CONT. <br />(1) #5 W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />VARIES PER- <br />36" MAX <br />ARCH PLANS <br />12" MIN <br />° ° d I�\ VAPOR BARRIER <br />/lx/%\�//� <br />/ FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />/ <br />6" OPT. EXTENSION b <br />IN BRICK LOCATIONS <br />ON FND PLAN 12" UNDER 1 STORY WALL W% (2) <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />I#4 OR (2) #5 CONT J <br />MONOLOTHIC FOOTING SECTION - 3611 MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE 1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR <br />FIBERMESH STUCCO OR DIRECTLY ADHERED Cl) E, <br />STONE CLADDING FINISH - MIN 6" Q, <br />CD <br />ca <br />ALL OTHER EXTERIOR WALL �' <br />\\ \\ \\ \\ \\ \\ o b, ° CLADDING - MIN 8", U.N.O. ON ARCH O a <br />LO <br />VAPOR BARRIER APEX <br />12MIN <br />U <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 _1 <br />BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL w/tds <br />(2) #5 OR (3) #4 CONTINUOUS W <br />J Q <br />J true design studios Q) <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOO <br />R PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: Y' <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211' <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. O �' <br />C) <br />CONCRETE SLAB w/ 6x6 L ' <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR al <br />FIBERMESH'. <br />DIHOMN <br />0 i'4 4-� 1 <br />W �I <br />16"' VAPOR BARRIER Q <br />U <br />3 BEARING WALL FOOTING SECTION U <br />z <br />W <br />wThis item has been electronically <br />CONCRETE SLAB W/ 6x6 signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />W1.4 x W1 A WWF OR shown using a digital signature. <br />FIBERMESH p Printed copies of this document are <br />0'-0" A.F.F. O not considered signed and sealed <br />° SEE ARCH � and the signature must be verified <br />a ° DETAILS (` by a 3rd Party Certificate Authority <br />�on any electronic copy <br />8" MIN O v' <br />J <br />Uj <br />Z <br />8"x8" THICKENED 8" U) W <br />FTG AT W <br />STEP-DOWN, SEE VAPOR BARRIER W <br />PLAN z z W <br />4 CURB STEP SECTION m Uj O (n <br />W QW <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W! I--�—►I 6" UNDER WOOD WALL J W Q Q <br />6x6 W1.4 x W1.4 WWF I I L� W <br />OR FIBERMESH VARIES d SEE ARCH Q Uj Q , , ' <br />(MAX 16") W <br />- <br />\\ o <br />LL LL �— <br />�/\ d ,/ 12"MIN./ �— <br />/\\ °\��\\\i\�j/\\\/\\\/\\j/�\\ 0 z <br />a VAPOR BARRIER �// ° %//�/// O <br />< <br />T/ 6" OPT. EXTENSION IN BRICK <br />LOCATIONS ON FND PLAN <br />� z Z <br />12" UNDER 1 STORY WALL w/ O a- <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 C) LL <br />BAR IN BRICK LEDGE <br />Q <br />16" UNDER 2 STORY WALL w/ W <br />(2) #5 OR (3) #4 CONTINUOUS —1 <br />Abbott Park Q <br />�-GARAGE EXT WALL CURB SECTION OJ co <br />5 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 037-03 - 0 <br />FOLLOWING OCCUR:ILLI <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 0 Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY U <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: W <br />CONCRETE SLAB W/ 6x6 O 2021.009231 <br />W1.4 x W1.4 WWF OR O LL <br />FIBERMESH z DRAWN: O <br />0'-0" A.F.F. = o <br />SEE ARCH U JAR C)\\ \\ \\ d 4 d — _ _ — DEEP) (MAX0 CHID: MJP U) <br />a d W L0 <br />° a d <br />d J <br />4" EXTENSION x U <br />UNDER BRICK VENEER Q jiN' Lq ,�� <br />12" UNDER 1 STORY WALL } �����•• ••••• N/�'Q � � <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m ; •• �\ G E N S�.••• ��� Z <br />- No 85166 �S <br />16" UNDER 2 STORY WALL WD;Signed by: <br />w/ (3) #4 OR (2) #5 CONT z Q <br />LBEARING CURB STEP SECTION ��,. DGRF4.�.14/ <br />6 — --- 0 c� <br />Q '�. Fs •' • .. • C? �� Z <br />z ��� Si0 • �` ��� > <br />i I <br />TYPICAL REINFORCING <br />j BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />jL---—— — — — — —— <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />%% Q <br />_O 07-28-2021 p <br />F- W <br />U REVISIONS: <br />Q No. Description F Date 'LU <br />~ <br />U) J <br />0 W <br />O <br />1 O <br />O z <br />Z <br />C) <br />W <br />x W ST=2mD <br />a <br />CMUiMETAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.