Laserfiche WebLink
lh�rn'u+fllnlw�le�.'i!�rt"! r� i� � i <br />DocuSign Envelope ID: FF875270-6EF9-44CE-896A-F76FB6A8ECA0 <br />EXISTING EXTERIOR CMU i <br />I <br />I <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO - <br />EXISTING FOUNDATION FACE w/ D <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. 1 <br />D EXISTING FOUNDATION. <br />D ° <br />p D <br />I � <br />D \ <br />A ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0' _0" A.F.F. SEE ARCH <br />(MAX 20" <br />- 4- - o <br />- <br />a a DEEP) <br />4 ° 4 <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />'4- 4 4 <br />04 <br />\/\\ 4 ° <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />-LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />) 90 DEGREE <br />L <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB oL BLOCK W/ (1) #4 OR #5 CONT. <br />I CD <br />cr <br />VAPOR BARRIER //\\// I LO <br />Lu o X <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.\/\\ <br />4 TO 5 COURSES: 48" O.C.\/�/ /\/ j�/ - <br />FOOTING TO BEAR ON FIRM ` /�\\\'/ #6 NI ONAL BIRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w - U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 ¢ J CONTOR #5 <br />WWF OR FIBERMESH > y _ w w <br />rwo <br />� FINISH <br />/\//\\7 \ <br />\/ GRADE <br />/\/\ < //\\ <br />#4 OR #5 VERT REINFORCING �\ I ' / <br />UP TO 3 COURSES: 72" O.C. \//\\// <br />4 TO 5 COURSES: 48" O.C. \/� <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR <br />UNDISTURBED SOIL #5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />07 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />WWF OR FIBERMESH <br />TO BOTTOM OF WINDOW SILL CMU STEMWALL MONO LITHIC SLAB 3 %' CONCRETE SLAB W/ 6x6 <br />WHERE NEEDED (1) #4 OR #5 CONT: W1.4 x W1.4 <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />CONTINUOUS TO EXTEND MIN 24" <br />j INTO MONOLITHIC THICKENED EDGE - - _ - - <br />MIN 24" LAP VARIES PER <br />MIN. 3" EDGE DISTANCE <br />36" MAX ARCH PLANS <br />6x6 W1.4 x CONCRETE <br />SLAB <br />/ ° a <br />STRIP OF WWF FROM F.F.E. TO _ _ _ _ _ OR FIBER MESH \r ^�\�T \\ 7\/��� %/ \\ <br />BOTTOM OF FTG. WWF TO ° a --- - - - -- - - - - - 1- - - - - - /\\12" MIN VAPOR BARRIER <br />- - - w z a . r\/\/\ \ / / FOOTING TO BEAR ON FIRM <br />D / ; - -p- u ° o ] O S ° // / / / / ` 4• UNDISTURBED SOIL <br />EXISTING FOUNDATION FACE w/ ° -� - D " 4 " <br />(2) ROWS OF 3/s' DIA. TAPCONS - - •I ° ° #4 OR #5 <br />OR CUT NAILS @ 24" O.C. COVER / ° O U z 4 ° ° ° ° ° ° REINFORCING PER r \ <br />D <br />FLUSH w/ 3000psi CONCRETE. I v� " ° ° 4MONOLITHIC FOOTING° 4 SECTION <br />EXISTING FOUNDATION 6" OPT. EXTENSION b <br />D TION ~ ° ° IN BRICK LOCATIONS <br />_ _ D U ° FOOTING TO BEAR ON FIRM ON FND PLAN <br />UNDISTURBED SOIL F10 UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL N0.4 OR NO. 5 1#4 OR (2) #5 CONT <br />\/ <br />D ° 4 \ \ \ \ \ BAR IN BRICK LEDGE -- <br />° MIN12 <br />4° "// <br />I ° \ n \ 16" UNDER 2 STORY WALL W/ (3) <br />/ / / / / //. #4 OR (2) #5 CONT <br />�� �� /\//\//\//\//\//\//\// /\//\//\// MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />8 CMU WALL OVERHANGS 2.5 OR LESS /\\/\\/\\/\\/\\/\\/\\� �\ \\�\\� STEMWALLFOOTINGTOEXTENDMIN <br />�\///\ \ 12' BELOW MONOLITHIC FOOTING "NOTE": IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />NOTES: \\/\\/r\\r\\�� • ADDITIONAL #4 OR #5 VERTICAL TO BE FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, /' /' LOCATED WITHIN TRANSITION ZONE <br />DEPTH EXCEEDS 28". <br />LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />EXISTING FOUNDATION AND 4 EMBED INTO EXISTING BOND BEAM. TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />7- <br />u o v <br />VAPOR BARRIER <br />SEE NOTES (MAX 16") U <br />E <br />M'\ O <br />U <br />ALL OTHER EXTERIOR WALL }' <br />Cr <br />CLADDING - MIN 8", U.N.O. ON ARCH O p <br />/ / / � APE0 <br />S <br />\��\//\//\//\//\//\ e-C <br />- <br />\ 12" M I N\/\\/\\/\\/\\/\� N c <br />0 N <br />m <br />cc <br />0 <br />STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH - MIN 6" a> <br />0 <br />N <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK r- <br />FIRM UNDISTURBED � <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ cM <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 _ <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ L <br />(2) #5 OR (3) #4 CONTINUOUS J tds -6 <br />true design studios () <br />1 MONOLITHIC FOOTING SECTION o <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE U) <br />FOLLOWING OCCUR: Y N <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <SUITE 100, JACKSONVILLE, FL 32211 Cn <br />O <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O 'a <br />O 4- <br />CONCRETE SLAB w/ 6x6 W � <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH 01N70 <br />N <br />\\\\\ T �'\\j\\ d ° n ��\�j\\ N > ®&Ake <br />w <br />/ VAPOR BARRIER <br />16" � <br />0 <br />CA <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />O This item has been electronically <br />W signed and sealed by Justin M Lanier, <br />CONCRETE SLAB W/ 6x6 PE on the date and/or time stamp <br />W1.4 x W1.4 WWF OR shown using a digital signature. <br />FIBERMESH O Printed copies of this document are <br />0'-0" A.F.F. O not considered signed and sealed <br />a SEE ARCH I and the signature must be verified <br />_ by a 3rd Party Certificate Authority <br />e a 4 \, DETAILS �on any electronic copy <br />LO <br />\ �\ /\/�\�;� 8" MIN �^^ <br />Z /� Q VJ <br />�\ W <br />8"x8" THICKENED 8" U) Q / <br />FTG AT 0. <br />STEP-DOWN, EE VAPOR BARRIER (Z Z W <br />PLAN <br />CURB STEP SECTION m LLJ O w <br />4 - <br />LU 0 �- <br />W O8" UNDER MASONRY WALL Z <br />6" UNDER WOOD WALL Z Q Q <br />CONCRETE SLAB W/ � <br />6x6 W1.4 x W1.4 WWF W W W <br />OR FIBERMESH VARIES ° � In <br />SEE ARCH <br />-a " -- ° (MAX 16") � L� Uj <br />r1_ <br />VAPOR BARRIER <br />° // //\// / /\ LL X <br />\ /\/\/\\/\\ \\ \\ \ <br />12" MIN./\/\/\/\/\� Z <br />W <br />6" OPT. EXTENSION IN BRICK O F- <br />LOCATIONS ON FND PLAN Q_ Z <br />O a <br />ADDITIONAL NO. 4 OR NO. 5 U U_ <br />BAR IN BRICK LEDGE Q - <br />0 <br />Abbott Park JQ <br />5 GARAGE EXT WALL CURB SECTION _ _ 0 <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 022-02 w <br />FOLLOWING OCCUR: - F- <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. <br />PROJECT NO: W O Q <br />CONCRETE SLAB W/ 6x6 -U 2021.009232 LL_ <br />W1.4 x W1.4 WWF OR Z _. _ O <br />FIBERMESH DRAWN: <br />_ 0� 0''°_F'F' SEE ARCH V CD 0 <br />- a - - - - Y (MAX 20" W - <br />- U') <br />4 ° °I DEEP) H CHKD: MJP <br />\ \\ \\ 4 x <br />a <br />4" EXTENSION <br />UNDER BRICK VENEER < <br />����`�S�(1N LANj �,� , <br />i <br />12" UNDER 1 STORY WALL } ��� ,J•'N C E N • F,4 <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER Q `� • : •�,� `SF '•• !' Z <br />No 85166 <br />16" UNDER 2 STORY WALL Z Z DocuSigned by: • ;• k <br />W/ (3) #4 OR (2) #5 CONT =c . <br />0 <br />06BEARING CURB STEP SECTION W . p;, Fp1�711�EF4�(/` <br />P'• �� <br />C` •. OR1 G �. Z <br />TYPICAL REINFORCING <br />THICKENEDBARS AT FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />I <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />p 07-29-2021 <br />F= W <br />U REVISIONS: _ <br />U_ _ <br />Q No. Description Date W <br />� J <br />O 0 <br />Z Z <br />= O <br />U <br />W <br />I- <br />x <br />W T=2sD <br />Q. <br />CMUIMETAL CONNECTOR ENGINEERING¢ <br />