Laserfiche WebLink
DocuSlgn Envelope ID: 9B428CE4-E6EB-4E3F-80CB-590519F9314F <br />EXISTING EXTERIOR CMU <br />I <br />I <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D ° D <br />D EXISTING FOUNDATION. <br />p D <br />D � D <br />I � <br />D \ <br />• <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/16" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />P -e - <br />D ° D <br />D EXISTING FOUNDATION <br />D ° <br />p D <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />-°--,----- (MAX 20" <br />DEEP) <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL <br />16" UNDER 2 STORY WALL <br />VAPOR BARRIER <br />6 BEARING CURB STEP SECTION <br />4 ° <br />16" <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />L.VI\ 1 IIV VVVJ VVIYVI\L 1 L <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CONCRETE SLAB W/ - <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />U) <br />LLJ <br />C:) <br />W 0 <br />/ H U <br />VAPOR BARRIER - �I <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />\\/ �N L <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM #5 //�\ #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE --- w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1 A U J (1) #4 OR #5 <br />WWF OR FIBERMESH > ¢ ¢ co CONT <br />LU� FINISH <br />• � -°. O GRADE <br />\ \\ <br />�/xx 'x/j\ \ <br />/\�//\/j\ <br />\\//\�/ <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. // D <br />i � I <br />_o <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CANT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />T_STEMWALL CURB SECTION_ <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CMU STEMWALL�ftk MONO LITHIC SLAB 3 %" CONCRETE SLAB W/ 6x6 <br />8" CMU CHAIR BLOCK W! (1) #5 (1) #4 OR #5 CONT.- W1.4 x W1.4 WWF OR FIBERMESH <br />CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP ° ° a <br />36" MAX VARIES PER o - - - - - -- - - <br />ARCH PLANS <br />4' CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />- -- OR FIBER MESH <br />VAPOR BARRIER <br />TO BEAR <br />wZ--------- -ir.e° a 8•�---<--a-a\\12" MINFOOT <br />O • 4 ° ° 9• ° #4 OR #5 /�% \ //\�// j 4'' j UND SING TURBED SOILON FIRM <br />p • , ° REINFORCING PER <br />U Z ° MONOLITHIC FOOTING ' <br />^ ° SECTION 6" OPT. EXTENSION b <br />IN BRICK LOCATIONS --- <br />g 4, . FOOTING TO BEAR ON FIRUNDISTURBED SOIL ON FND PLAN 1T UNDER 1 STORY WALL W/ (2) <br />• ° \ \ \ \ ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />° ^ " I 4° MINI 12"' //\//\//\//\//\//\//\/ BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />4 • - _ -° < d ° //\\//\\//\\//\\//� #4 OR (2) #5 CONT <br />\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING *NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />LOCATED WITHIN TRANSITION ZONE DEPTH EXCEEDS 28". <br />LOCATE AND TIE INTO STEMWALL FOOTING IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />REINFORCEMENT IN LAST REINFORCEMENT STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING <br />Z) <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") U <br />W1.4 x W1.4 WWF OR d <br />FIBERMESH STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH - MIN 6" p <br />ALL OTHER EXTERIOR WALL `li <br />\\ \\ \\ \\ \\ \\ p o CLADDING - MIN 8", U.N.O. ON ARCH O Ap <br />0 <br />" MINA <br />VAPOR BARRIER �// D \\ 12\/\\/\\/\\/\\/\� N P U <br />4. <br />FOOTING TO BEAR ON 6 OPT. EXTENSION IN BRICK <br />FIRM UNDISTURSBOED IL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M zz <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J +, <br />BAR IN BRICK LEDGE ILL. <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS W <br />J tds J-6 <br />� <br />true design studios <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. (D <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. C ) <br />O <br />CONCRETE SLAB w/ 6x6 co <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W C_ <br />FIBERMESH ~ d <br />041HOMON <br />LLI <br />16" VAPOR BARRIER Q <br />C) <br />W <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />U' This item has been electronically <br />CONCRETE SLAB W/ 6x6 W signed and sealed by Justin M Lanier, <br />Of PE on the date and/or time stamp <br />W1.4 x W1.4 WWF OR O shown using a digital signature. <br />FIBERMESH O Printed copies of this document are <br />0'-0" A.F.F. O not considered signed and sealed <br />O; and the signature must be verified <br />SEE ARCH <br />a by a 3rd Party Certificate Authority <br />a \4 DETAILS �on any electronic copy <br />8" MIN (] V i a <br />Z LIJ <br />8"x8" THICKENED 8" W <br />FTG AT n/ <br />STEP-DOWN, SEE VAPOR BARRIER � � z W-�� <br />PLAN <br />4 CURB STEP SECTION m Uj O W <br />W <br />W Q <br />w Q O <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL w ' '�I Q a <br />6x6 W1.4 x W1.4 WWF W <br />OR FIBERMESH VARIES 4 LU <br />SEE ARCH 0 Q 2 <br />a� - ° (MAX 16") w �L�j/ <br />x <br />L <br />//\ \ /�\\i \\\\\\/\\\/\\\\\ O <br />VAPOR BARRIER \/�\° 4 �• �/- \ /�//�//,///\/ Z <br />O <br />W <br />6" OPT. EXTENSION IN BRICK (-- <br />LOCATIONS ON FND PLAN N� Z <br />LL <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 O LL <br />- BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL w/ Q W <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park -' <br />O U <br />5 GARAGE EXT WALL CURB SECTION - <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE U- LOT 023-02 W <br />FOLLOWING OCCUR: <br />F- <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z_ Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY C7 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: LU <br />CONCRETE SLAB W/ 6x6 O 2021.009233 <br />W1.4 x W1.4 WWF OR O W <br />FIBERMESH Z DRAWN: O <br />0'-0" A.F.F. SEE ARCH U JAR o <br />(MAX 20" W --- to <br />4 ° a vl a --° ° DEEP) CHKD: MJP <br />K ° 4 4„ W J <br />° e <br />4" EXTENSION Q U <br />UNDER BRICK VENEER N� �� <br />12" UNDER 1 STORY WALL %- �`,``,JS�•�'� E nj •N/�.9 , <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m �� .••�,� SF •.• ,��� Z <br />16" UNDER 2 STORY WALL W•• NO 85166 <br />w/ (3) #4 OR (2) #5 CONT Z 7t ;• DocuSigned by: <br />6 BEARING CURB STEP SECTION W � e71DA�DEF�4 <br />Q '��� Fsi • ; •O R 10. • �� ��`� Z <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />L. - - - - - - - - - - <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />O 07-28-2021 <br />~ W <br />U_ REVISIONS: <br />U- H <br />Q No. Description Date <br />W <br />to Q <br />O Z <br />Z O <br />2 � <br />U <br />W <br />x <br />W ST=2mD <br />CMUIMETAL CONNECTOR ENGINEERING <br />