Laserfiche WebLink
DocuSign Envelope ID: A3E9FD1A-D987-46A6-B10D-9D4233C65975 <br />DESIGN CRITERIA AND LOADS <br />Building Code <br />Florida Building and Residential Codes , <br />7tt' Edition (2020) <br />Code for Design Loads <br />ANSI/ASCE 7-16 <br />ROOF LOADING' ............................................... <br />Cd = 1.25 <br />TOP CHORD LIVE LOAD .................................. <br />20 PSF <br />TOP CHORD DEAD LOAD................................7 <br />PSF (TILE = 15 PSF) <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE ............... <br />20 PSF <br />ATTICS WITHOUT STORAGE ....................... <br />10 PSF <br />(NON -CONCURRENT) <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />WIND LOADING ................................................. <br />Cd 1.60 <br />ASCE 7-16, 3S GUST........................................139 <br />MPH <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY..................................0 <br />BUILDING CATEGORY.....................................II <br />ENCLOSURE CLASSIFICATION ...................... <br />ENCLOSED <br />INTERNAL PRESSURE COEFF...................... <br />0.18 <br />C&C DESIGN PRESSURES.. .. <br />- (SEETABLE 1) <br />FLOOR LOADING ............ .......................... <br />........ Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................40 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD..........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING ... .Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................60 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD ...........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD ........................ <br />5 PSF <br />MAXIMUM FLOOR TRUSS SPACING..............16" <br />O.C. <br />DEFLECTION CRITERIA <br />LL / 240 <br />ROOF TRUSSES .............................................. <br />TL / 180 <br />TL MAX 1" UP TO 40' SPAN <br />LL / 480 <br />TL / 360 <br />OPEN WEB FLOOR TRUSSES ....................... <br />LL / 480 <br />TL/240 <br />WOOD I JOISTS ............................................... <br />TL MAX'/2" <br />LL / 360 <br />BEAMS'.............................................................TL <br />/ 240 <br />NOTES: <br />1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL <br />ABOVE SHALL NOT EXCEED 3/4" DEFLECTION <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />ZONE DESIGNATION <br />IZ - Interior Zone (psf) <br />EZ - End Zone (psf) <br />0-20 ft2 <br />+28.54 -30.96 <br />+28.54 <br />-38.22 <br />21 - 50 ft2 <br />+27.17 -29.59 <br />+27.17 <br />-35.47 <br />51 - 100 ft2 <br />+25.52 -27.94 <br />+25.52 <br />-32.17 <br />101 - 200 ft2 <br />+24.25 -26.67 <br />+24.25 <br />-29.64 <br />SOFFIT MAX PRESSURE (psf) <br />+28.6 <br />-38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24.6 <br />END ZONE KEY MAP <br />- END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1ST 4.0' PER FIGURE R301.2 (7) <br />1 <br />1 i <br />1 ST FLOOR ( 0 F <br />TYP) <br />END ZONE <br />DESIGNATION <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />NOTES 3.4 <br />p O <br />STUCCO AND DIRECTLY <br />MIN'%2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR ('/6" 24/16 <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE <br />l Q N <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />ww� <br />U J z <br />ALL OTHER VENEER <br />MIN 1%/ '32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); <br />a <br />6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />x c9 rn <br />TILE AND METAL ROOF <br />MIN 1V32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />= <br />(NOTE 7) <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND <br />Lu <br />6" O.C. IN THE FIELD <br />LL p w � <br />MIN'/16" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />O z0 <br />SHINGLE ROOF <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />2%32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN %" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN %2" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 /8" COOLER NAIL OR NO.6 x 1 %" LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES: <br />1. FOR SHEATHING THICKNESS GREATER THAN 1%2" CATEGORY, USE RSRS-03 NAILS. <br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS. <br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO <br />REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />6. 1V32" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN <br />STRUCTURAL REQUIREMENTS ARE %e' 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />7. 1V32" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, 1V32" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />9 THBEEN <br />SIZE ENGINEERED RESIST ASCE7-1N ACCORDANCE WITH FRC 221 <br />TABLE 4 NAIL LEGEND TABLE 5FASTENERS IN <br />NOTES 1, 2, 3, 4 DIAMETER PRESSURE TREATED LUMBER <br />1 11 <br />LENGTH <br />8d COMMON <br />0.131" <br />2-'/2" <br />RSRS-01 <br />0.113" <br />2 3/8' <br />RSRS-03 <br />0.131" <br />2-'/2" <br />10d <br />0.131" <br />3" <br />10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3-%" <br />16d SINKER <br />0.148" <br />3-'/4" <br />16d COMMON <br />0.162" <br />3-'/2" <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />ALL OTHER PT <br />Z-MAX, G120 OR TRIPLE ZINC <br />(INCLUDING ACQ & MCQ) <br />COATED FINISH. <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />NOTES: <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE <br />0 <br />SHALL NOT EXCEED 75 /o OF THE NAIL OR SPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2' TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN <br />ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY, IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10. TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). <br />2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, <br />THIS SHEET. <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />NOTES 2. 3. 4 <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />MITEK <br />USP FASTENERS <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />MITEK <br />USP FASTENERS <br />(8)'Y, X 1 %" SIDS SCREWS <br />(8)'%" x 1%" WS15-GC <br />DTT2Z <br />IN STUD''/2' 0 X 4'/2" <br />WOOD SCREWS IN STUD <br />(9) 10d COMMON <br />(9) 10d <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />'Y2 0 x 4'%" EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />EACH END <br />(18)0.162"x2'/z"IN <br />(18)0.162"x2'Y2"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(7) 10d x 1 'h" <br />(7) 10d x 1 '/2" <br />(NOTE 2) <br />�8" 0 x 6" EMBED ANCHOR <br />HTT45 <br />§8, O x 6" EMBED ANCHOR <br />MTS12 <br />EACH END <br />MTW12 <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 '/2" IN <br />(26) 0.162" x 2 '/2" IN <br />HTT5 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(9) 10d COMMON <br />(9) 10d COMMON <br />(NOTE 2) <br />�8" 0 x 6" EMBED ANCHOR <br />HTT45 <br />48" 0 x 6" EMBED ANCHOR <br />MSTA24 <br />EACH END <br />MSTA24 <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(20)W' x 3" SIDS SCREWS <br />(24) 3" WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP 7 " 0 x 12" EMBED <br />a <br />MSTA36 <br />(13) 10d COMMON <br />MSTA36 <br />(13) 10d COMMON <br />78" Q x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />(7) 10d COMMON IN <br />(7) 10d COMMON IN <br />(7) 10d x 1 %" IN TRUSS <br />(7) 10d x 1 %" IN TRUSS <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />MSTAM36 <br />WOOD FRAMING <br />MSTAM36 <br />WOOD FRAMING <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(4) 'W x 2 '/<" TITEN <br />(5) '%" x 2 'W TAPCON IN <br />SCREWS IN MASONRY <br />(11) 10d x 1 '/2" IN <br />MASONRY <br />(11) 10d x 1 '/2" IN <br />(8) 10d x 1 ''/2" IN TRUSS <br />(9) 10d x 1 '/2" IN TRUSS <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(11) 10d x 1 %" IN <br />(11) 10d x 1 '/2" IN <br />STUD <br />(12) 10d x 1 '/2" IN <br />STUD <br />(8) 10d x 1'/2" IN <br />ABU44 <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />(NOTE 6) <br />48" 0 x 7 EMBED EPDXY <br />PAU44 <br />48 0 x 7 EMBED EPDXY <br />HTSM20 <br />(12) 10d x 1 /2 IN <br />HTWM20 <br />(4) W x 3" WEDGE BOLT <br />STUD <br />(5) 8d x 1'/2" IN <br />OR EQUIVALENT IN STUD <br />(5) 8d x 1'/2" IN <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />ABU66 <br />4 " O x 7' EMBED EPDXY <br />PAU66 <br />% " 0 x 7' EMBED EPDXY <br />H2.5T/ <br />TRUSS <br />RT7/ <br />TRUSS <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />(12" EMBED AT GARAGE <br />HA8 <br />(5) 8d x 1'/2" IN <br />RT7AT <br />' (5) 8d <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />(5) 10d x 1 %" IN <br />TOP PLATE <br />(5) 10d x 1'/2" IN <br />HU48, <br />(14) 16d COMMON IN <br />HD481 <br />(14) 16d COMMON IN <br />HUC48, <br />HEADER <br />HD481F, <br />HEADER <br />H8 <br />TRUSS <br />RT8A <br />TRUSS <br />HU28-2, <br />HD28-2, <br />(5) 10d x 1'/2" IN <br />(5) 10d x 1'Y2" IN <br />HUC28-2 <br />(6) 10d COMMON IN BEAM <br />HD28-21F <br />(6) 10d COMMON IN BEAM <br />TOP PLATE <br />TOP PLATE <br />(16) 10d COMMON TO <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />LGT2 <br />(7) �'/d' x 2 W TITEN <br />LUGT2 <br />(5)'0" x 3" WEDGE BOLT <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />(26) 16d SINKER <br />OR EQUIVALENT <br />(28) 16d SINKER IN WALL <br />(22) 16d COMMON IN <br />(22) 16d COMMON IN <br />HUC212-2 <br />HEADER <br />HD212-21F <br />HEADER <br />LGT3 <br />IN WALL FRAMING <br />LUGT3 <br />FRAMING <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />(12) SIDS W x 2'/2" <br />(12) WS25 ''/a" x 2''/2" <br />(4)%" x 1 '/2' SIDS SCREW <br />(4) %" x 1'/2" WS15 SCREWS <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGA10KT <br />(4)1/," x 3" SIDS SCREWS <br />HGA10 <br />(4) '%" x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, <br />SDWC15600 <br />NO <br />USP EQUIVALENT <br />(4) SIDS %" x 1 '/2' SCREWS <br />(4) '%" x 1 %" WS15 SCREWS <br />HGAM10KT <br />IN TRUSS/RAFTER <br />'W <br />HGAM10KT <br />IN TRUSS/ RAFTER <br />(4) /< x 1 /, WEDGE BOLT <br />(4) x 2%" TITEN SCREWS <br />L_ <br />IN MASONRY <br />OR EQUIVALENT IN <br />MASONRY <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES. <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2'/2" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />'/ 0 x 2 3/4" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF'Y," 0 x 1 %" TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />3. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. fc = 3,000 PSI. <br />4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". <br />6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING <br />7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />>Lu <br />_w <br />N � <br />LEGEND <br />O _j <br />N" <br />OR <br />"OR" SHALL MEAN THAT EITHER OPTIC N PROVIDED IS AN EQUAL <br />ALTERNATIVE FOR THE APPLICATION : ;HOWN <br />E <br />UNO <br />UNLESS NOTED OTHERWISE ON PLAN OR DETAIL <br />O <br />FOR <br />ENGINEER OF RECORD <br />V <br />EW <br />EACH WAY <br />O <br />> <br />i3 <br />OSB <br />ORIENTED STRAND BOARD <br />O <br />O <br />WSP <br />WOOD STRUCTURAL PANEL <br />T. <br />O <br />SYP <br />SOUTHERN YELLOW PINE <br />APEX <br />SPF <br />SPRUCE -PINE -FUR <br />� <br />U <br />CONT <br />CONTINUOUS <br />N <br />O.C. <br />ON CENTER <br />Nr <br />LSL <br />1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 3/" WIDE, UNO. <br />0') <br />g <br />(3 %" WIDE LSL BEAMS ARE EQU TALENT TO 2-PLY 1 3/4" BEAM) <br />LVL <br />2.0E MICROLLAM LVL ENGINEERED LU v1BER, 1 3/4" WIDE <br />�- <br />PSL <br />2.0E PARRALLAM PSL ENGINEERED LL MBER, 3 '/2' WIDE, UNO. <br />N <br />SYS 42 <br />PROPERLY RATED OPEN WEB HEADEF <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS <br />OUTLINED ON TYPICAL WALL SECTION 3, DETAIL SHEETS <br />LL <br />tds <br />LLI <br />INTERIOR BEARING WALL WITH NO UP _IFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM <br />J <br />-6 <br />BOTTOM PLATE ANCHORAGE IS ''/2" AN CHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR <br />true c9esa studios <br />>: <br />SW SPECIFICATIONS) <br />z <br />STRUCTURAL WOOD BEAM Y <br />STUD COLUMN KEYNOTE UQ <br />NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. <br />� <br />O <br />NUMBER OF STUDS BELOW BEAM/GIRL )ER TRUSS. STUDS <br />O <br />TO MATCH WALL FRAMING SIZE AND G RADE, UNO. <br />2 2 STUDS <br />U) w <br />H <br />ADDITIONAL CLARITY FOR THE LOCATI DIN OF THE STUD COLUMN <br />2 <br />ANCHOR <br />Imo - <br />BOTTOM OF STUD COLUMN CONNECTI DIN <br />1 ST LEVEL STUD COLUMN: HOLDDOV'N REQUIRED AT BASE OF COLUMN > <br />2ND LEVEL STUD COLUMN: STRAPPIt G REQUIRED FROM 2ND LEVEL J <br />COLUMN TO 1ST LEVEL STUDS/HEAD --R/BEAM. m <br />"ANCHOR" REQUIRES BOTTOM PLATE ,kNCHOR WITHIN 3" OF STUD COLUMN W <br />NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE <br />Q <br />HEADER STRAPPING KEYNOTE <br />NUMBER OF STRAPS CONNECTING HE ADER TO JACK STUD 0 <br />1 <br />MSTA24 <br />TYPE OF STRAP CONNECTING HEADEI: TO JACK STUD <br />C) <br />KING/JACK GROUP BOTTOM CONNECT ION <br />z <br />W <br />1ST LEVEL STUD GROUP: HOLDDOW J REQUIRED AT BASE OF STUD GROUP <br />(D <br />T7!� <br />2ND LEVEL STUD COLUMN: STRAPPII IG REQUIRED FROM 2ND LEVEL STUD <br />LLI <br />GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. <br />W <br />NUMBER OF HOLD DOWNS/STRAP S AT BASE OF KING/JACK GROUP <br />O <br />O <br />NON -BEARING HEADER FRAMING KEY!JOTE <br />NO HDR - # <br />NUMBER OF KING STUDS EACH SIDE C F OPENING <br />HEADER MAY BE FRAMED AS NON BEA RING HEADER DUE TO LIGHTLY <br />r <br />LOADED CONDITIONS ABOVE <br />0 <br />z <br />#2 SYP HEADER FRAMING KEYNOTE <br />(2)2, 10- 1 / 2 <br />NUMBER OF KING STUDS EACH SIDE C F OPENING <br />U) <br />(n <br />W <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING <br />z <br />Z) <br />DEPTH OF LOAD -BEARING #2 SYP HEA DER <br />NUMBER OF PLIES IN HEADER <br />m <br />W' <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE <br />IW <br />(2) 9'/2" LSL- 1 / 2 <br />NUMBER OF KING STUDS EACH SIDE C F OPENING <br />z <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING <br />Z <br />HEADER MATERIAL (LSL, LVL, PSL, OF: SYS42) <br />W <br />DEPTH OF LOAD -BEARING EWP HEADER <br />Q <br />NUMBER OF PLIES IN HEADER (1 %" WIDE UNO) <br />HEADER FRAMING <br />° <br />J <br />LL <br />1. <br />ALL HEADER JACK AND KING STU IDS SHALL BE FASTENED FO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. <br />z <br />STAGGERED. <br />0 <br />2. <br />NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDI FIONS, 49" OR LESS CLEAR -OPENINGS IN AN <br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADEF , SEE PLAN. <br />Q <br />3. <br />FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROV /S 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. <br />� <br />4. <br />FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAI .S <br />0 <br />5. <br />IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECO RD. <br />a- <br />6. <br />UNO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STUD \ND (1) SDWC15450 KING STUD TO BOTTOM PLATE <br />O <br />0 <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST <br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS AB DVE. <br />7. <br />TOP PLATE TO HEADER CONNECTION PER ONE OF THE FO -LOWING (NO CONNECTION REQUIRED FOR <br />Q <br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WF EN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: <br />• SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 <br />W <br />0 <br />• SPH w/ (12) 10d x 1-'/2" @ 16" O.C. OR <br />J <br />• DSP w/ (14) 10d x 1-'/2" @ 16" O.C. OR <br />W <br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w' (14) 10d x 1-%" (OR EQUAL APPROVED BY EOR). <br />Q <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MA` BE FRAMED AT 24" O.C. <br />FRAMING NOTES <br />0 <br />z <br />0 <br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USE D IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. <br />U <br />ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCIl' G STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN <br />0 <br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GF EATER THAN SPECIFIED ANCHOR DIAMETER). <br />z <br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE i,ND WOOD BOTTOM PLATE. MANUFACTURER'S <br />2 <br />SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTAL LATION. <br />W <br />2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR D RY USE ONLY, LINO. ALL WATERPROOFING AND FIRE SAFETY <br />� <br />SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR 4ND ARE TO BE DESIGNED AND DETAILED BY OTHER. <br />"ION <br />X <br />3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDI' TO FRAMING FASTENER REQUIREMENTS LISTED IN <br />W <br />TABLE 2304.10.1 <br />0- <br />4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. <br />Q <br />5. FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. <br />X <br />UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDE R LOCATIONS TO BE CONTINUOUS THROUGH FLOOR <br />Q <br />SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADEF: JACK/KING STUD GROUPS) <br />6. FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)? d TOE NAILS OR (2)16d COMMON END NAILS. <br />m <br />7. FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. <br />8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLII i STUD GROUP BELOW MATCHING GIRDER OR BEAM <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS A S NOTED ON STRUCTURAL PLAN, UNO. <br />W <br />9. EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATI ]ED WITH OSB OR PLYWOOD <br />z <br />5. <br />O <br />W <br />Q <br />z <br />U) <br />Z) <br />O <br />U_ <br />Q <br />U) <br />O <br />O <br />2 <br />0 <br />W <br />X <br />w <br />a_ <br />Q <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />';3 <br />06RO <br />HOMN, <br />N <br />y <br />0 <br />This item has been electronically <br />signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />shown using a digital signature. <br />Printed copies of this document are <br />not considered signed and sealed <br />and the signature must be verified <br />by a 3rd Party Certificate Authority <br />�on any electronic copy <br />a co <br />Uj LLI <br />J z Of <br />W <br />LLJ OU) <br />Q <br />Q O <br />Q Q <br />Lu 0 <br />W � I� <br />X <br />Q LjL r- <br />z <br />O <br />0 <br />W <br />z <br />10- <br />LL <br />W <br />Abbott Park J <br />U <br />U) <br />LOT 035-03 0 <br />W <br />F- <br />Q <br />Cn <br />PROJECT NO: W <br />2021.009229 0 <br />LL <br />O <br />DRAWN. <br />JAR o <br />CHKD lL0 <br />MJP W <br />W <br />J <br />Q <br />0 <br />oJINLA ' ND W ��•,� <br />i 0 <br />No 85166 <br />* DocuSigned by:• <br />•• �f 67{�EDEF433" .. <br />i A, ••� <br />;i�9/ON <br />Q <br />Of <br />07-28-2021 0 <br />w <br />REVISIONS: <br />No. Description Date w <br />- Q <br />co <br />- I- <br />O <br />O <br />ST=1 <br />CMUIMETAL CONNECTOR ENGINEERING <br />